Uji Selektivitas dan Validitas Teknik Flow Injection Analysis (FIA) untuk Penentuan Merkuri pada Sampel Limbah Berbasis Penurunan Absorbansi Kompleks Iodium-amilum

Permata, Lia Marisca (2017) Uji Selektivitas dan Validitas Teknik Flow Injection Analysis (FIA) untuk Penentuan Merkuri pada Sampel Limbah Berbasis Penurunan Absorbansi Kompleks Iodium-amilum. Sarjana thesis, Universitas Brawijaya.

Abstract

Merkuri (Hg) merupakan logam berbahaya yang dapat mempengaruhi ekologi dan kesehatan masyarakat. Limbah merkuri banyak dihasilkan pada sektor pertambangan emas rakyat sekala kecil. Pengembangan metode otomatis yang sederhana, cepat dan valid diperlukan untuk pemantauan kadar merkuri(II) secara kontinyu di area yang rawan pencemaran merkuri. Pada penelitian ini, telah dikembangkan analisis merkri(II) dengan metode Flow Injection Analysis-Spektrofotometry (FIA-Spektrofotometri) yang didasarkan pada penurunan absorbansi kompleks iodium-amilum. Merkuri(II) yang direaksikan dengan iodida (I-) berlebih akan membentuk kompleks tidak berwarna tetraiodomerkurat(II) [HgI4]2-. Sumber iodida yang tersisa kemudian dioksidasi oleh iodat (IO3 -) dalam suasana asam untuk membentuk iodium (I2). Iodium dengan adanya amilum akan membentuk kompleks biru [I2-amilum] yang diukur menggunakan spektrofotometer sinar tampak pada panjang gelombang 618 nm. Parameter penelitian yang dilakukan adalah uji selektivitas terhadap ion asing dan uji validitas dengan metode adisi standar. Hasil dari penelitian ini menunjukkan bahwa kisaran konsentrasi yang dapat terdeteksi adalah 1-10 mg.L-1. Metode ini tidak diganggu oleh adanya anion CN- pada konsentrasi hingga 50 mg.L-1 namun ion S2- sangat mengganggu pada kisaran konsentrasi 5-50 mg.L-1. Uji validasi telah dilakukan pada sampel sintetis dan 3 sampel alami yang merupakan limbah pertambangan emas, dimana baik sampel sintetis dan tiga sampel alami menunjukkan % recovery yang tinggi yaitu 107,5 %; 93,8 %; 96,1 % dan 97,2 %

English Abstract

Mercury (Hg) is a hazardous metal that can affect ecology and public health. Mercury waste was produced in small-scale gold mining sector. The development of simple, fast, and valid automatic method is necessary for continous monitoring of mercury levels in area where mercury contamination. In this research, analysis of mercury was determined by FlA-Spektrophotometric method based on the decrease of absorbance of starch-iodine complex. Mercury that reacted with an excess of iodide (I-) forming a colorless complex of tetraiodomercurat(II) [HgI4]2-. The remaining iodide source will be oxidized by iodate in acidic condition to form iodine (I2). Iodine and starch forming a blue-starch-iodine-complex that is detected by spectrofphotometer with 618 nm wavelength. The research parameters are selectivity test of foreign ions and validity test with standar adition method. The results showed that linear concentration of mercury that can be measured was 0-10 mg.L-1. This method was not interfered by CN- anion up to 50 mg L-1, but S2- anion is interfered at 5-50 mg.L-1. Validation test has been applied on synthetic and three natural samples wich are small-scale gold mining waste. The test showed high recovery with respective values of 107.5 %; 93.8 %; 96.1 % and 97.2 %

Item Type: Thesis (Sarjana)
Identification Number: SKR/FMIPA/2017/391/051709731
Uncontrolled Keywords: Merkuri(II), FIA, tetra-iodo-merkuri(II), kompleks iodium-amilum, selektivitas, validitas
Subjects: 500 Natural sciences and mathematics > 543 Analytical chemistry > 543.1 General topics in analytical chemistry > 543.19 Techniques of general application / Instrumental analysis
Divisions: Fakultas Matematika dan Ilmu Pengetahuan Alam > Kimia
Depositing User: Nur Cholis
Date Deposited: 19 Oct 2017 06:53
Last Modified: 22 Nov 2021 04:17
URI: http://repository.ub.ac.id/id/eprint/4049
[thumbnail of BAB 3.pdf]
Preview
Text
BAB 3.pdf

Download (222kB) | Preview
[thumbnail of BAB 4.pdf]
Preview
Text
BAB 4.pdf

Download (324kB) | Preview
[thumbnail of BAGIAN DEPAN.pdf]
Preview
Text
BAGIAN DEPAN.pdf

Download (211kB) | Preview
[thumbnail of BAB 5.pdf]
Preview
Text
BAB 5.pdf

Download (86kB) | Preview
[thumbnail of DAFTAR PUSTAKA.pdf]
Preview
Text
DAFTAR PUSTAKA.pdf

Download (140kB) | Preview
[thumbnail of Lampiran.pdf]
Preview
Text
Lampiran.pdf

Download (301kB) | Preview
[thumbnail of BAB 1.pdf]
Preview
Text
BAB 1.pdf

Download (109kB) | Preview
[thumbnail of BAB 2.pdf]
Preview
Text
BAB 2.pdf

Download (393kB) | Preview

Actions (login required)

View Item View Item