Pengembangan Bioelectrical Impedance Spectrometer (BIS) Yang Bekerja Secara Cepat Dengan Fasilitas Bode Dan Nyquist Plot

Pitaloka, Bella (2019) Pengembangan Bioelectrical Impedance Spectrometer (BIS) Yang Bekerja Secara Cepat Dengan Fasilitas Bode Dan Nyquist Plot. Magister thesis, Universitas Brawijaya.

Abstract

Parameter impedansi dalam bahan biologis dapat menjadi salah satu indikator klinis untuk menentukan karakteristik suatu bahan biologis. Dalam penelitian ini dibuat sistem pengukuran impedansi listrik berbasis impedansi bioelektrik spektrometer. Sistem ini terdiri dari pengukuran elektroda, sumber arus AC terkontrol, pemrosesan data dan software penampil. Sumber arus AC dapat bekerja dengan frekuensi dari 100 Hz hingga 100 kHz dengan nilai arus yang dapat dikontrol melalui PC. Akuisisi data dilakukan menggunakan ADC mikrokontroler dan GPD (gain and phase detector) AD8302. AD8302 digunakan untuk mendeteksi perbedaan amplitudo dari referensi dan bahan uji dengan kisaran -30dB hingga 30dB, serta perbedaan fase dari -90 derajat hingga 90 derajat. Data yang telah diproses oleh mikrokontroler dikirim ke perangkat lunak untuk diproses. Nilai impedansi dan fase dihitung secara otomatis oleh perangkat lunak. Data ditampilkan dalam bentuk plot Bode dan plot Nyquist. Hasil penelitian menunjukkan bahwa sistem yang dikembangkan mampu membedakan perubahan konsentrasi larutan asam yang dicampur dalam air mineral. Hanya sekitar 1 menit waktu yang dibutuhkan untuk melakukan proses pengukuran.

English Abstract

Impedance parameters in biological material become a clinical indicator to determine whether a biological material is healthy or not in terms of cell damage based on the value of impedance. In this research, an electrical impedance measurement system based on bioelectrical impedance spectrometer has been made. The system consists of measuring electrodes, controlled AC current sources, data processing and display software. The AC current source can work with frequency from 100 Hz to 100 kHz with a current value that can be controlled via a PC. Data acquisition is made using a microcontroller, ADC and AD8302 GPD. AD8302 is used to detect differences in amplitude from references and test materials with range of -30dB to 30dB, as well as phase differences from -90 degrees to 90 degrees. Data that has been processed by the microcontroller is sent to the software for processing. Impedance and phase values are calculated automatically by the software. Data is displayed in the form of Bode plot and Nyquist plot. The experimental results show that the developed system is able to distinguish changes in the concentration of acid mixed in mineral water. It’s only about 1 minute to do measurement process

Other obstract

-

Item Type: Thesis (Magister)
Identification Number: TES/543.5/PIT/p/2019/042000441
Uncontrolled Keywords: IMPEDANCE SPECTROSCOPY
Subjects: 500 Natural sciences and mathematics > 543 Analytical chemistry > 543.5 Optical spetroscopy (Spectrum analysis)
Divisions: S2/S3 > Magister Fisika, Fakultas MIPA
Depositing User: Budi Wahyono Wahyono
Date Deposited: 14 Jan 2020 07:28
Last Modified: 25 Oct 2021 06:26
URI: http://repository.ub.ac.id/id/eprint/177901
[thumbnail of Bella Pitaloka (2).pdf]
Preview
Text
Bella Pitaloka (2).pdf

Download (6MB) | Preview

Actions (login required)

View Item View Item