Pengaruh Variasi Tekanan Chamber Terhadap Nilai Temperatur Dan Densitas Elektron Pada Diagnostik Plasma Nitrogen Menggunakan Spektroskopi Emisi Optik

Wibowo, Gigih Satriyo (2018) Pengaruh Variasi Tekanan Chamber Terhadap Nilai Temperatur Dan Densitas Elektron Pada Diagnostik Plasma Nitrogen Menggunakan Spektroskopi Emisi Optik. Sarjana thesis, Universitas Brawijaya.

Abstract

Penelitian diagnostik plasma nitrogen menggunakan spektroskopi emisi optik Aurora 4000 pada modifikasi lapisan polistirena telah dilakukan. Diagnostik dilakukan pada kondisi chamber tanpa sampel dan ada sampel didalamnya. Diagnostik dilakukan dengan plasma pada variasi tekanan chamber adalah 20,30,40,50, dan 60. Hasil diagnostik menunjukkan bahwa nilai temperatur elektron turun seiring dengan kenaikan tekanan chamber. Hal ini disebabkan karena semakin tinggi tekanan semakin besar jumlah N partikel sehingga untuk setiap distribusi persebaran energi, tiap partikel akan menerima energi lebih kecil. Densitas elektron dan intensitas meningkat seiring kenaikan tekanan, disebabkan oleh semakin banyak reaksi ionisasi yang menghasilkan elektron dan disosiasi gas menjadi radikal sehingga jumlah elektron dan emisi optik plasma meningkat. Pengukuran nilai sudut kontak air pada sampel dengan perlakuan plasma menunjukkan terjadi peningkatan hidrofilisitas pada permukaan.

English Abstract

In this research, nitrogen plasma on polystyrene’s films treatment was diagnosed by using an optical emission spectroscopy Aurora 4000. Chamber pressure variation used in this research are 20, 30, 40, 50, and 60 Pa. The results of this research show that electron temperature was decreased by increasing chamber pressure. By increasing chamber pressure, the number of N particles increased, so every particle received less energy. The opposite results obtained by increasing chamber pressure, electron density and emission intensity increased. By increasing chamber pressure, the probabilty of ionization and dissociation reactions increased, so the amount of electron and plasma optical emission increased. The measurement of water contact angle show that the hydrophilicity of surface changed due to plasma treatment. Hydrophilicity increased by plasma treatment on sample’s surface

Item Type: Thesis (Sarjana)
Identification Number: SKR/MIPA/2018/555/051901806
Uncontrolled Keywords: Plasma Nitrogen, Temperatur Elektron, Densitas Elektron, Hidrofilisitas. Nitrogen Plasma, Electron Temperature, Electron Density, Hydrophilicity
Subjects: 500 Natural sciences and mathematics > 543 Analytical chemistry > 543.5 Optical spetroscopy (Spectrum analysis)
Divisions: Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika
Depositing User: Budi Wahyono Wahyono
Date Deposited: 17 Jun 2020 07:27
Last Modified: 19 Oct 2021 01:29
URI: http://repository.ub.ac.id/id/eprint/168231
[thumbnail of Gigih Satriyo Wibowo (2).pdf]
Preview
Text
Gigih Satriyo Wibowo (2).pdf

Download (3MB) | Preview

Actions (login required)

View Item View Item