Modifikasi Screen Printed Carbon Electrode (Spce) Dengan Polipirol-Sio2 Untuk Penentuan Fenol

Pratiwi, Erasti (2018) Modifikasi Screen Printed Carbon Electrode (Spce) Dengan Polipirol-Sio2 Untuk Penentuan Fenol. Magister thesis, Universitas Brawijaya.

Abstract

Fenol merupakan jenis polutan berbahaya yang banyak dijumpai dalam air, makanan kaleng, udara dan produk kimia. Fenol juga bersifat karsinogenik bagi manusia, sangat beracun, sulit terdegradasi di alam, dan dapat menyebabkan gangguan kesehatan meskipun dengan kadar yang rendah. Oleh karena itu diperlukan kontrol terhadap kadar fenol, sehingga diperlukan metode analisis yang sensitive, akurat dan teliti. Metode elektrokimia menggunakan elektroda termodifikasi merupakan teknik yang menjanjikan karena mempunyai sensitivitas yang tinggi. Modifikasi permukaan elektroda dapat dilakukan dengan penambahan berbagai substansi seperti oksida logam, polimer dan enzim, salah satunya yaitu dengan melapiskan permukaannya menggunakan polimer konduktif yaitu polipirol (Ppy). Polipirol telah banyak diaplikasikan untuk modifikasi elektroda karena memiliki konduktifitas yang tinggi yaitu 102 –7,5×103 S/cm, memiliki sifat penghantar arus listrik, sifat mekanik yang baik, mudah disintesis dalam pelarut air dan ketebalan film dapat dikendalikan dengan proses elektropolimerisasi. Selain itu, digunakan juga nanopartikel silikon oksida (SiO2) yang dapat meningkatkan kepekaan pada elektroda dan memiliki luas permukaan yang besar. Tujuan dari penelitian ini adalah untuk pengukuran fenol dengan menggunakan material yang dilapisi pada permukaan elektroda kerja screen printed. Pada penelitian ini terdapat 2 material yang nantinya dimodifikasi pada elektroda kerja dari SPCE. Dua material tersebut yaitu SiO2 dan Polipirol(Ppy)- SiO2. Kedua material tersebut dilapiskan pada permukaan elektroda karbon screen printed. Permukaan dari material tersebut akan dikarakterisasi dengan SEMEDAX. Pada material termodifikasi Polipirol (Ppy)-SiO2 dilakukan dengan metode elektropolimerisasi dengan potensial 0 – 0,9 V terhadap Ag/AgCl. Kedua hasil modifikasi dipilih salah satu elektroda modifikasi terbaik yang dapat digunakan untuk penentuan fenol. Pemilihan pH opimum elektroda termodifikasi diperoleh berdasarkan hasil pengujian larutan fenol dalam buffer asetat pada pH 3 – 5 dengan voltametri siklik dan differential pulse voltammetry (DPV) yang dimodifikasi SiO2 dan Polipirol(Ppy)-SiO2. Kondisi optimum dipilih berdasarkan potensial dan arus yang dihasilkan yaitu pada pH 5 Hasil modifikasi elektroda pada pH optimum digunakan untuk penetuan fenol dengan metode differential pulse voltammetry (DPV). Pengukuran fenol dilakukan dalam media buffer asetat dan buffer fosfat pada pH 5. Rentang kosentrasi fenol yang digunakan pengukuran yaitu 0,01; 0,05; 0,10; 0,50; 1,00; 5,00 mM. Berdasarkan hasil penelitian ini diperoleh kepekaan yaitu 7,93 μA/mM.

English Abstract

Phenol is a dangerous type of pollutant commonly found in water, canned food, air and chemical products. Phenols are also carcinogenic to humans, highly toxic, difficult to degrade in nature, and can cause health problems even at low levels. Therefore it is necessary to control the content of phenol, so that required method of analysis that is sensitive, accurate and accurate. The electrochemical method using modified electrodes is a promising technique because it has high sensitivity. The modification of the electrode surface can be accomplished by the addition of various substances such as metal oxides, polymers and enzymes, one of which is by superimposing the surface using a conductive polymer of polypyrrole (Ppy). Polypyrrole has been widely applied to the modification of the electrode because it has a high conductivity that is 102 –7.5×103 S/cm, has electrical conductor properties, good mechanical properties, easily synthesized in water solvents and the film thickness can be controlled by electropolimerization process. In addition, silicon oxide nanoparticles (SiO2) are used which can increase the sensitivity of the electrodes and have large surface area. The purpose of this study was to measure phenol by using coated material on the screen printed electrode surface. In this study there are 2 materials that will be modified on the working electrode of SPCE. The two materials are SiO2 and polypyrrole (Ppy)-SiO2. Both materials are superimposed on the surface of the screen printed carbon electrodes. The surface of the material will be characterized by SEM-EDAX. In polypyrrole- SiO2 modified material is performed by electropolimerization method at potential 0 – 0.9 V vs Ag/AgCl. Both modified results are selected one of the best modified electrodes which can be used for the determination of phenol. Selection of the pH of the modified electrode was obtained based on the results of the test of phenol solution in pH 3 - 5 with a cyclic voltammetry and a modified SiO2 and polypyrrole-SiO2 modified voltammetry differential (DPV). The optimum condition was chosen based on the potential and current generated at pH 5. The result of modification of electrode at optimum pH was used for phenol determination by differential pulse voltammetry (DPV) method. Phenol measurements were carried out in acetate buffer medium and phosphate buffer at pH 5. The phenol concentration range used was 0.01; 0.05; 0.10; 0.50; 1.00; 5.00 mM. Based on the results of research obtained sensitivity of 7.93 μA/mM

Item Type: Thesis (Magister)
Identification Number: TES/547.632/PRA/m/2017/041801066
Uncontrolled Keywords: PHENOL, ELECTROCHEMISTRY
Subjects: 500 Natural sciences and mathematics > 541 Physical chemistry > 541.3 Miscellaneous topics in physical chemistry > 541.37 Electrochemistry and magnetochemistry
Divisions: S2/S3 > Magister Kimia, Fakultas MIPA
Depositing User: Nur Cholis
Date Deposited: 26 Mar 2018 08:29
Last Modified: 21 Oct 2021 01:02
URI: http://repository.ub.ac.id/id/eprint/8969
[thumbnail of BAB IV.pdf]
Preview
Text
BAB IV.pdf

Download (185kB) | Preview
[thumbnail of BAB I.pdf]
Preview
Text
BAB I.pdf

Download (298kB) | Preview
[thumbnail of BAB V.pdf]
Preview
Text
BAB V.pdf

Download (477kB) | Preview
[thumbnail of BAB III.pdf]
Preview
Text
BAB III.pdf

Download (178kB) | Preview
[thumbnail of BAB II.pdf]
Preview
Text
BAB II.pdf

Download (614kB) | Preview
[thumbnail of BAB VI.pdf]
Preview
Text
BAB VI.pdf

Download (6kB) | Preview
[thumbnail of BAGIAN DEPAN.pdf]
Preview
Text
BAGIAN DEPAN.pdf

Download (307kB) | Preview
[thumbnail of COVER .pdf]
Preview
Text
COVER .pdf

Download (89kB) | Preview
[thumbnail of Halaman Depan.pdf]
Preview
Text
Halaman Depan.pdf

Download (287kB) | Preview
[thumbnail of Lampiran 1.pdf]
Preview
Text
Lampiran 1.pdf

Download (259kB) | Preview
[thumbnail of DAFTAR PUSTAKA.pdf]
Preview
Text
DAFTAR PUSTAKA.pdf

Download (378kB) | Preview
[thumbnail of Lampiran 2.pdf]
Preview
Text
Lampiran 2.pdf

Download (347kB) | Preview

Actions (login required)

View Item View Item