Mubarok, Naufal Fadhil and Dr. Drs. Unggul Pundjung Juswono, M.Sc. and Firdy Yuana, S.Si., M.Si. (2024) Analisis Pengaruh Increment Dan Number Of Arcs Terhadap Sebaran Dosis Target Dan Organ Terdampak Dengan Menggunakan Teknik Vmat Dan Sinar Foton 6 Mv Pada Pasien Penderita Retinoblastoma Di Instalasi Radioterapi Rumah Sakit Hasan Sadikin. Sarjana thesis, Universitas Brawijaya.
Abstract
Metode pengobatan kanker yang umum digunakan untuk kasus retinoblastoma adalah radioterapi, pada pelaksanaan radioterapi tentu perlu dilakukannya perencanaan agar dosis radiasi yang dikirimkan tepat ke target, dan hal ini membutuhkan penyesuaian parameter seperti increment dan number of arcs. Penelitian ini bertujuan untuk menganalisis dampak penggunaan increment dengan variasi nilai yang berbeda terhadap sebaran dosis pada target dan OAR serta nilai HI dan CI, selain itu dilakukan studi analisis dari dampak penggunaan number of arcs dengan variasi nilai yang berbeda terhadap sebaran dosis pada target dan OAR serta nilai HI dan CI. Metode penelitian yang digunakan adalah simulasi TPS pada kasus retinoblastoma dengan menggunakan software MONACO. Hasil penelitian menunjukkan bahwa increment tidak berpengaruh terlalu signifikan terhadap distribusi dosis pada target dan OAR serta nilai HI dan CI, sebaliknya number of arcs berpengaruh cukup signifikan terhadap distribusi dosis pada target dan OAR serta nilai HI dan C. Kesimpulan dari penelitian ini adalah bahwa perlu dilakukan uji parameter lain untuk mengetahui pengaruh increment.
English Abstract
The commonly used treatment method for retinoblastoma is radiotherapy. In the implementation of radiotherapy, careful planning is essential to ensure that the radiation dose is precisely delivered to the target. This requires adjusting parameters such as increment and number of arcs. The purpose of this study is to analyze the impact of using increments with different values on dose distribution to the target and OAR, as well as on HI and CI values. Additionally, the study aims to analyze the impact of using a different number of arcs on dose distribution to the target and OAR, as well as on HI and CI values. The research method used is TPS simulation for retinoblastoma cases using MONACO software. The results show that increment does not significantly affect dose distribution to the target and OAR or HI and CI values. In contrast, the number of arcs significantly affects dose distribution to the target and OAR, as well as HI and CI values. The conclusion of this study is that further testing of other parameters is needed to understand the impact of increment.
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | 0524090343 |
Uncontrolled Keywords: | retinoblastoma, increment, number of arcs, VMAT |
Divisions: | Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika |
Depositing User: | Unnamed user with username nova |
Date Deposited: | 13 Dec 2024 02:08 |
Last Modified: | 13 Dec 2024 02:08 |
URI: | http://repository.ub.ac.id/id/eprint/229450 |
Text (DALAM MASA EMBARGO)
Naufal Fadhil Mubarok.pdf Restricted to Registered users only Download (2MB) |
Actions (login required)
View Item |