“Studi Pengaruh Variasi Kombinasi Filter Pada Pesawat Mammography Terhadap Dosis Radiasi dan Kualitas Citra”

Risalatul Latifah, S.Si, M.Si, and Drs. Johan Andoyo Effendi Noor, M.Sc., Ph.D, (2024) “Studi Pengaruh Variasi Kombinasi Filter Pada Pesawat Mammography Terhadap Dosis Radiasi dan Kualitas Citra”. Sarjana thesis, Universitas Brawijaya.

Abstract

Mammography menjadi salah satu alat pemindai dalam menangkap jaringan payudara dengan menggunakan sinar–X. Mammography mampu mendeteksi karakteristik massa dan mikrokalsifikasi yang menjadi pertanda dari kanker payudara. Organ payudara merupakan jaringan organ yang sensitif dan memiliki banyak saraf. Dalam menggunakan modalitas mammography, resiko efek negatif yang ditimbulkan tidak dapat dihindarkan. Salah satu proteksi radiasi dalam paparan medik pasien pada modalitas mammography adalah pengukuran dosis glandular rerata atau sering disebut mean glandular dose. Perhitungan mean glandular dose menggunakan perkalian antara kerma udara dengan faktor konversi dan faktor koreksi. Faktor konversi meliputi beberapa hal seperti pada kualitas berkas, ketebalan payudara dan half value layer. Filter menjadi salah satu faktor penentu dosis radiasi dan kualitas citra. Variasi kombinasi filter terhadap MGD dan kualitas citra yang terbentuk sehingga didapatkannya material filter yang sesuai dengan kualitas penerimaan dosis dan penggunaan mammography yang menjadi salah satu modalitas pendeteksi dini kanker payudara lebih optimal. Metode yang digunakan pada penelitian adalah deskriptif kuantitatif. Penelitian menggunakan objek berupa fantom mammography dan fantom slab . Pengeskposan fantom diambil kualitas citra dan kerma udara kemudian dihitung untuk hasil dari kualitas citra berupa jumlah serat, mikrokalsifikasi, massa, cnr dan snr. Pada hasil dari kerma udara berupa hasil mean glandular dose terhitung serta pengaruh tebal fantom slab terhadap mean glandular dose. Hasil yang diperoleh bahwa filter mempengaruhi hasil dosis dan kualitas citra Filter Mo/Mo menghasilkan tingkatan dosis yang lebih tinggi jika dibandingkan filter Mo/Rh. Pada hasil kualitas citra filter Mo/Rh menghasilkan nilai kualitas citra yang lebih baik tampilannya jika dibandingkan filter Mo/Mo. Pengaruh bahan dari filter menghasilkan tingkatan dosis dan kualitas citra yang berbeda pada tiap filter.

English Abstract

Mammography is one of the X-ray modalities equipment to visualize the anatomy of breast. Mammography is able to detect mass characteristics and microcalcifications that are a sign of breast cancer. The breast organ is also sensitive organ tissue and has many nerves. When using the mammography modality, the risk of negative effects is unavoidable. One of the radiation protections in the patient's medical exposure to the mammography modality is the measurement of the average glandular dose, often called the mean glandular dose. The calculation of the mean glandular dose uses the multiplication of the air kerma with conversion factors and correction factors. The conversion factor includes several things, such as beam quality, breast thickness, and the half-value layer. Filters are one of the factors that determine the radiation dose and image quality. Variations in filter combinations on MGD and image quality are formed so that the filter material is obtained in accordance with the quality of dose reception, and the use of mammography, which is one of the modalities for early detection of breast cancer, is more optimal. The method used in the research is descriptive-quantitative. The research used objects in the form of mammography phantom and slab phantom. Exposure of the phantom was taken to determine image quality, and air kerma was then calculated for the results of image quality in the form of the number of fibers, microcalcifications, mass, cnr, and snr. The results of air kerma in the form of calculated mean glandular dose results and the effect of phantom slab thickness on mean glandular dose. The results obtained show that the filter affects the dose results and image quality. Mo/Mo filters produce higher dose levels when compared to Mo/Rh filters. In the image quality results, the Mo/Rh filter produces a better image quality value than the Mo/Mo filter. The influence of the material of the filter produces different dose levels and image quality for each filter.

Item Type: Thesis (Sarjana)
Identification Number: 0524090285
Uncontrolled Keywords: Mammography, mean glandular dose, kualitas citra, filter mammography
Divisions: Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika
Depositing User: Unnamed user with username nova
Date Deposited: 02 Dec 2024 01:28
Last Modified: 02 Dec 2024 01:28
URI: http://repository.ub.ac.id/id/eprint/228824