Analisa Pengaruh Parameter Grid Spacing Dan Number Of Field Terhadap Nilai Indeks Kesesuaian Dan Nilai Indeks Homogenitas Pada Perencanaan Radioterapi Dengan Teknik 3dcrt Dan Teknik Imrt Terhadap Kanker Serviks Dengan Energi Foton 6 Mv Di Rs Lavalette

Salsabila, Tasya Rizki and Dr. Drs. Unggul Pundjung Juswono, M.Sc., and Firdy Yuana, S.Si., M.Si., (2024) Analisa Pengaruh Parameter Grid Spacing Dan Number Of Field Terhadap Nilai Indeks Kesesuaian Dan Nilai Indeks Homogenitas Pada Perencanaan Radioterapi Dengan Teknik 3dcrt Dan Teknik Imrt Terhadap Kanker Serviks Dengan Energi Foton 6 Mv Di Rs Lavalette. Sarjana thesis, Universitas Brawijaya.

Abstract

Kasus kanker serviks di dunia menduduki peringkat ke empat dan peringkat kedua di indonesia. Kanker ini disebabkan oleh pertumbuhan abnormal atau perubahan sel pada serviks. Kebanyakan disebabkan oleh virus yang disebut Human Papillomavirus (HPV). Untuk melakukan pengobatan pada penyakit kanker dapat dilakukan tindakan radioterapi dimana salah satu modalitas utamanya adalah Linear Accelerator (LINAC). Pesawat LINAC memiliki dua teknik perencanaan pengobatan kanker yaitu Three-Dimensional Conformal Radiotherapy (3DCRT) dan Intensity Modulated Radiotherapy (IMRT). Penelitian dilakukan dengan mengevaluasi perbandingan nilai indeks kesesuaian dan indeks homogenitas serta menganalisis besar dosis serap yang diterima OAR dan PTV pada tiap-tiap teknik pengobatan LINAC. Parameter yang dapat mempengaruhi hasil perencanaan radioterapi dari kedua teknik tersebut adalah grid spacing dan number of field. Pada penelitian ini dilakukan variasi number of field yaitu dengan 4 number of field (0°, 90°, 180°, 270° ) dan 5 number of field (0°, 72°, 144°, 216°, 288°.) agar diketahui distribusi dosis yang paling optimal. Selain itu, juga dilakukan variasi grid spacing dengan nilai dari 1 mm – 5 mm untuk mengetahui keakuratan perhitungan dosis. Hasil penelitian menyatakan bahwa teknik yang paling optimal dan efektif dalam mengobati kanker serviks dengan meminimalisir dosis OAR adalah teknik IMRT 5 number of field dan ukuran grid spacing 5 mm.

English Abstract

Cervical cancer cases in the world are ranked fourth in the world and second in Indonesia. This cancer is caused by abnormal growth or changes in cells in the cervix. Most cervical cancer is caused by a virus called Human Papillomavirus (HPV). To treat cancer, radiotherapy can be performed, one of the main modalities of which is the Linear Accelerator (LINAC) teletherapy device. The LINAC has two cancer treatment planning techniques, namely ThreeDimensional Conformal Radiotherapy (3DCRT) and Intensity Modulated Radiotherapy (IMRT). The research was carried out by evaluating the comparison of CI and HI values and analyzing the amount of absorbed dose received by OAR and PTV in each LINAC treatment technique. Parameters that can influence the results of radiotherapy planning from these two techniques are grid spacing and number of fields. In this research, variations in the number of fields were carried out, namely with 4 numbers of fields (0°, 90°, 180°, 270°) and 5 numbers of fields (0°, 72°, 144°, 216°, 288°.) so that determine the most optimal dose distribution. Apart from that, grid spacing variations were also carried out with values from 1 mm – 5 mm to determine the accuracy of the dose calculation. The research results stated that the most optimal and effective technique in treating cervical cancer is the IMRT technique with 5 numbers of fields and a grid spacing size 5 mm.

Item Type: Thesis (Sarjana)
Identification Number: 0524090248
Uncontrolled Keywords: kanker serviks, LINAC, radioterapi, indeks kesesuaian, indeks homogenitas.
Divisions: Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika
Depositing User: Unnamed user with username nova
Date Deposited: 15 Nov 2024 04:05
Last Modified: 15 Nov 2024 04:05
URI: http://repository.ub.ac.id/id/eprint/228119
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
Tasya Rizki Salsabila.pdf
Restricted to Registered users only

Download (3MB)

Actions (login required)

View Item View Item