Analisis Penggunaan Metode District Meter Area Terhadap Tingkat Kehilangan Air Pada Dma Ronggolawe (W2g) Kota Malang

Rasyid, Muhammad Nur and Prof. Dr. Ir. Bambang Suharto, MS and Dr. Eng. Akhmad Adi Sulianto, STP., MT., M.Eng (2024) Analisis Penggunaan Metode District Meter Area Terhadap Tingkat Kehilangan Air Pada Dma Ronggolawe (W2g) Kota Malang. Sarjana thesis, Universitas Brawijaya.

Abstract

Pelayanan air bersih untuk masyarakat yang disalurkan melalui sistem jaringan distribusi adalah salah satu aspek dari kesatuan sistem penyediaan air bersih yang memiliki peran sangat penting. Fungsi pokok dari jaringan pipa distribusi adalah untuk mengalirkan air bersih ke seluruh pelanggan dengan tetap memperhatikan faktor kualitas, kuantitas, dan kontinuitas. Salah satu upaya dalam meningkatkan pelayanan penyediaan air minum adalah dengan mengoptimalkan system penyediaan air minum dengan menurunkan kehilangan air baik fisik maupun non fisik. Kehilangan air fisik adalah kehilangan air yang secara nyata terbuang dari sistem distribusi sehingga tidak dapat dimanfaatkan. Sedangkan kehilangan air non fisik adalah hilangnya air yang tidak diketahui penyebabnya dan tidak terlihat secara langsung sehingga butuh di telusuri secara lebih lanjut. Cara mengurangi angka kehilangan air dapat dilakukan dengan memperbaiki kebocoran yang terlihat dan yang dilaporkan, memperbarui peta jaringan perpipaan, memanfaatkan deteksi alat kebocoran, dan mencari sambungan sambungan yang ilegal. Salah satu teknik untuk memantau kebocoran pada suatu wilayah yang kecil yaitu menggunakan metode District Metered Area (DMA). Pada sistem pendistribusian air Perumda Air Minum Tugu Tirta Kota Malang terbagi menjadi beberapa distrik yang kemudian disebut District Meter Area (DMA). Pada setiap District Meter Area (DMA) terdiri dari cakupan wilayah tertentu di mana ditentukan kebutuhan air berdasarkan jumlah rumah tangga yang tinggal dalam cakupan wilayah tersebut. Penelitian ini menggunakan metode District Meter Area (DMA) sebagai perlakuan yang diberikan kepada jaringan pipa untuk menurunkan tingkat kehilangan air pada wilayah DMA Ronggolawe. Dalam pengujian DMA yang dibentuk akan dilakukan uji Step Test untuk mengetahui apakah ada penurunan tingkat kehilangan air baik fisik ataupun non fisik pada jaringan pipa. Manfaat dari penelitian ini adalah untuk memberikan gambaran bahwa penggunaan Metode viii DMA baik untuk digunakan oleh Instansi penyedia air minum yang menggunakan jaringan pipa untuk pipa distribusinya guna mengisolasi wilayah agar sistem distribusi air berjalan dengan lebih baik.

English Abstract

Water services for the community which are distributed through the distribution network system are one aspect of the unified clean water supply system which has a very important role. The main function of the distribution pipe network is to deliver clean water to all customers while still paying attention to quality, quantity and continuity factors. One effort to improve drinking water supply services is to optimize the drinking water supply system by reducing both physical and non-physical water loss. Physical water loss is water loss that is actually wasted from the distribution system so that it cannot be utilized. Meanwhile, nonphysical water loss is water loss whose cause is unknown and cannot be seen directly, so it needs to be investigated further. How to reduce water loss can be done by repairing visible and reported leaks, updating pipe network maps, using leak detection tools, and looking for illegal connections. One technique for monitoring leaks in a small area is using the District Metered Area (DMA) method. In the water distribution system, Perumda Air Minum Tugu Tirta, Malang City is divided into several districts which are then called District Meter Areas (DMA). Each District Meter Area (DMA) consists of a certain area coverage where water needs are determined based on the number of households living within that area coverage. This research uses the District Meter Area (DMA) method as a treatment given to the pipe network to reduce the level of water loss in the Ronggolawe DMA area. In testing the DMA that is formed, a Step Test will be carried out to determine whether there is a decrease in the level of water loss, both physical and nonphysical, in the pipe network. The benefit of this research is to provide an illustration that the use of the DMA method is good for use by drinking water supply agencies that use pipe networks for their distribution pipes to isolate areas so that the water distribution system runs better.

Item Type: Thesis (Sarjana)
Identification Number: 052410
Uncontrolled Keywords: Distribusi Air, Kehilangan Air, Metode District Meter Area-Water Distribution, Water Loss, District Meter Area Method
Divisions: Fakultas Teknologi Pertanian > Keteknikan Pertanian
Depositing User: Unnamed user with username nova
Date Deposited: 02 Oct 2024 03:10
Last Modified: 02 Oct 2024 03:10
URI: http://repository.ub.ac.id/id/eprint/225817
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
MUHAMMAD NUR RASYID.pdf
Restricted to Registered users only

Download (3MB)

Actions (login required)

View Item View Item