Uzuhro, Aliya Salsabila and Dr. Eng. Chomsin Sulistya Widodo, S.Si., M.Si., Ph.D. and Risalatul Latifah, S.Si., M.Si. (2024) Evaluasi Pengaruh Ketebalan Slice Thickness Terhadap Kualitas Citra Ct-Scan (Studi Phantom Aapm). Sarjana thesis, Universitas Brawijaya.
Abstract
Slice thickness atau ketebalan irisan merupakan tebal tipisnya irisan citra medis, biasanya semakin tipis slice thickness semakin baik kualitas citranya. Pemilihan ketebalan slice thickness perlu diperhatikan karena akan berpengaruh besar pada kualitas citra. Oleh karena itu, perlu dilakukan uji kesesuaian secara berkala. Telah dilaksanakan uji kesesuaian untuk mengetahui pengaruh ketebalan slice thickness pada hasil kualitas citra pada pesawat CT-scan Hitachi Scenaria 128 slice di Unit Radiologi RSUD Karsa Husada Kota Batu dengan menggunakan phantom AAPM. Parameter yang digunakan ialah slice thickness, akurasi dan keseragaman CT number, akurasi dan keseragaman noise, dan Contrast-to-Noise Ratio (CNR). Variasi ketebalan yang digunakan mulai dari 0,625mm, 1mm, 1,25mm, 2,5mm, 3,75mm, 5mm, 7,5mm, dan 10mm dengan faktor eksposi 120 kV dan 200 mA. Dari pengujian yang penulis lakukan, ketebalan slice thickness memiliki pengaruh pada kualitas citra dan memberikan perbedaan nilai pada setiap parameter. Dari keenam parameter yang digunakan, ketebalan 3,75 mm memiliki nilai yang semuanya berada pada nilai batas toleransi sesuai standar BAPETEN Nomor 9 tahun 2011. Sehingga, pada ketebalan 3,75 mm inilah ketebalan slice thickness yang optimal digunakan dalam pencitraan dengan hasil kualitas citra paling baik dari yang lainnya.
English Abstract
Slice Thickness is the thickness of the medical image slices, usually the thinner the slice thickness, the better the image quality. The choice of slice thickness needs to be considered because it will have a big influence on image quality. Therefore, it is necessary to carry out balance tests periodically. A suitability test has been carried out to determine the effect of slice thickness on image quality results on a Hitachi Scenaria 128 slice CT-scan aircraft at the Radiology Unit of Karsa Husada Hospital, Batu City using an AAPM phantom. The parameters used include slice thickness, accuracy and uniformity of CT numbers, accuracy and uniformity of noise, and Contrast-to-Noise Ratio (CNR). The thickness variations used start from 0.625mm, 1mm, 1.25mm, 2.5mm, 3.75mm, 5mm, 7.5mm, and 10mm with an exposure factor of 120 kV and 200 mA. From the tests carried out by the author, the thickness of the slices has an influence on image quality and provides different values for each parameter. Of the six parameters used, the thickness of 3.75 mm has values that are all within the tolerance limit values according to BAPETEN standards Number 9 of 2011. So at a thickness of 3.75 mm this is the optimal slice thickness used in imaging with the best image quality results from the others.
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | 052409 |
Divisions: | Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika |
Depositing User: | Unnamed user with username nova |
Date Deposited: | 24 Sep 2024 06:39 |
Last Modified: | 24 Sep 2024 06:39 |
URI: | http://repository.ub.ac.id/id/eprint/224970 |
Text (DALAM MASA EMBARGO)
Aliya Salsabila Uzuhro.pdf Restricted to Registered users only Download (3MB) |
Actions (login required)
View Item |