Solihin, Afnanda Prio and Prof. Drs. Arinto Yudi Ponco Wardoyo, \, M.Sc., Ph.D. (2024) Penggunaan sensor mq-8 pada sistem monitoring konsentrasi senyawa benzo[a]pyrene menggunakan Robotdyn Uno R3 Wi-Fi dan ditampilkan pada Ubiq. Sarjana thesis, Universitas Brawijaya.
Abstract
BaP (Benzo[a]Pyrene) termasuk senyawa yang berbahaya dan sangat mencemari lingkungan, BaP berdampak buruk bagi kesehatan manusia dengan penyakit yang ditimbulkan seperti ISPA (Iritasi Saluran Pernapasan) BaP berasal dari pembakaran bahan organik yang tidak sempurna seperti emisi kendaraan dan pembakaran fosil. Berdasarkan hal tersebut penelitian ini diperlukan untuk memonitoring BaP secara real-time. Sistem menggunakan mikrokontroler Robotdyn Uno Wi-Fi R3, sensor gas MQ 8 yang dikalibrasi dengan BaP, LCD 20x4 dan platform visual Ubiq yang akan menampilkan data secara real-time. Sistem ini juga menggunakan database MySQL dan SD card untuk menyimpan data monitoring. Hasil monitoring yang dilakukan, sistem ini memiliki rentang pengukuran BaP 0-32 ppm dengan akurasi sensor 82% dan performa pengiriman data ke database MySQL didapatkan akurasi 92% dengan jangkauan antara sistem dengan router kurang dari10 meter. Kesimpulannya sistem ini dapat digunakan untuk memonitoring konsentrasi senyawa BaP dari emisi yang ada diudara secara real-time dan diketahui performa sistem dengan sensor MQ 8 terhadap pengukuran konsentrasi BaP.
English Abstract
BaP (Benzo[a]Pyrene) is a harmful compound and a significant environmental pollutant. BaP negatively impacts human health, causing diseases such as respiratory tract irritation. It originates from the incomplete combustion of organic materials, such as vehicle emissions and fossil fuel burning. Based on this, research is needed to monitor BaP in real-time. The system uses a Robotdyn Uno Wi-Fi R3 microcontroller, an MQ 8 gas sensor calibrated for BaP, a 20x4 LCD, and the Ubiq visual platform to display data in real-time. This system also utilizes a MySQL database and an SD card to store monitoring data. The monitoring results show that this system has a BaP measurement range of 0-32 ppm with a sensor accuracy of 82% and a data transmission performance to the MySQL database with an accuracy of 92% within a range of less than 10 meters from the system to the router. In conclusion, this system can be used to monitor the concentration of BaP compounds from airborne emissions in realtime, and the system's performance with the MQ 8 sensor for BaP concentration measurement is established.
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | 0524090107 |
Uncontrolled Keywords: | Monitoring, Benzo[a]Pyrene, MQ 8, Robotdyn UNO WI-Fi, Ubiq |
Divisions: | Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika |
Depositing User: | Unnamed user with username nova |
Date Deposited: | 01 Jul 2024 06:19 |
Last Modified: | 01 Jul 2024 06:19 |
URI: | http://repository.ub.ac.id/id/eprint/220939 |
Text (DALAM MASA EMBARGO)
Afnanda Prio Solihin.pdf Restricted to Registered users only Download (5MB) |
Actions (login required)
View Item |