Analisis Kondisi Minyak Transformator Dengan Uji Dissolved Gas Analysis (Dga) Dan Breakdown Voltage Pada Pt Pln Nusantara Power Up Muara Karang

Layla Badriyah, Intan and Drs. Ir. Moch Dhofir, M.T. and Dr. Tri Nurwati, S.T., M.T (2024) Analisis Kondisi Minyak Transformator Dengan Uji Dissolved Gas Analysis (Dga) Dan Breakdown Voltage Pada Pt Pln Nusantara Power Up Muara Karang. Sarjana thesis, Universitas Brawijaya.

Abstract

Penelitian ini bertujuan untuk mendapatkan kondisi minyak transformator berdasarkan hasil uji Dissolved Gas Analysis (DGA) dan Breakdown Voltage pada PT PLN Nusantara Power UP Muara Karang. Pembahasan dilakukan dengan menganalisis minyak transformator pada dua transformator yang berbeda yaitu transformator yang mengalami gangguan dan transformator yang sedang beroperasi (aktif). Pada metode DGA dilakukan perhitungan dengan metode interpretasi untuk mengetahui permasalahan yang terjadi. Metode interpretasi data yang dilakukan yaitu metode TDCG, rasio roger, key gas, dan segitiga duval. Dengan dilakukan pengujian DGA, dilakukan untuk mengetahui lebih jelas permasalahan yang dapat terjadi pada transformator. Selanjutnya, Pada pengujian dengan menggunakan metode Breakdown Voltage, dilakukan untuk mendapatkan nilai tegangan tembus dari minyak. Hasil penelitian menunjukan bahwa berdasarkan pengujian breakdown voltage, transformator yang mengalami gangguan maupun transformator aktif berada pada kondisi normal karena berada di atas nilai standarnya (40 kV/2,5 mm). Sedangkan, berdasarkan pengujian DGA, transformator yang mengalami gangguan memiliki indikasi gangguan berupa thermal fault disertai dengan partial discharge dan kerusakan pada isolasi kertas, sedangkan pada transformator aktif memiliki indikasi thermal fault yang disertai dengan kerusakan isolasi kertas.

English Abstract

This research aims to obtain the condition of the oil transformer based on the results of the Dissolved Gas Analysis (DGA) and Breakdown Voltage tests at PT PLN Nusantara Power UP Muara Karang. The discussion was carried out by analyzing oil transformers on two different transformers, namely the transformer that was experiencing problems and the transformer that was operating (active). In the DGA method, calculations are carried out using an interpretation method to find out the problems that occur. The data interpretation methods used are the TDCG method, Roger's ratio, key gas, and Duval's triangle. By carrying out DGA testing, it is carried out to find out more clearly the problems that can occur in the transformer. Next, testing using the Breakdown Voltage method is carried out to obtain the breakdown voltage value of the oil. The research results show that based on breakdown voltage testing, the faulty transformer and active transformer are in normal condition because they are above the standard value (40 kV/2.5 mm). Meanwhile, based on DGA testing, the faulty transformer has an indication of a thermal fault accompanied by an electric arc discharge and damage to the paper insulation, while the active transformer has an indication of a thermal fault accompanied by damage to the paper insulation.

Item Type: Thesis (Sarjana)
Identification Number: 0524070034
Uncontrolled Keywords: Minyak transformator, tegangan tembus, kandungan gas, DGA
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: Unnamed user with username nova
Date Deposited: 13 Jun 2024 06:53
Last Modified: 13 Jun 2024 06:53
URI: http://repository.ub.ac.id/id/eprint/219902
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
Intan Layla Badriyah.pdf
Restricted to Registered users only

Download (4MB)

Actions (login required)

View Item View Item