Pengaruh Perbesaran Luas Elektroda Terhadap Tegangan Tembus Pada Dielektrik Udara Menggunakan Sumber Tegangan Tinggi AC

Angkasa, Aulia and Drs. Ir. Moch. Dhofir, M.T. and Prof. Dr. Ir. Rini Nur Hasanah, S.T., M.Sc., IPU., ASEAN Eng. (2024) Pengaruh Perbesaran Luas Elektroda Terhadap Tegangan Tembus Pada Dielektrik Udara Menggunakan Sumber Tegangan Tinggi AC. Sarjana thesis, Universitas Brawijaya.

Abstract

Peristiwa tegangan tembus (breakdown) atau tembus listrik sering terjadi sebagai peristiwa kegagalan sistem isolasi pada suatu peralatan listrik baik dalam dielektrik cair berupa minyak maupun pada dielektrik gas berupa udara. Contoh fenomena tegangan tembus pada sistem tenaga listrik seperti gardu induk yaitu tegangan tembus antara dua kontak/konduktor circuit breaker (CB) atau Traformator di gardu induk. Perbedaan dimensi ukuran luas pada dua kontak/konduktor circuit breaker berpengaruh pada distribusi medan listrik sekitar kontak sehingga dapat mempengaruhi probabilitas terjadinya tegangan tembus antara dua kontak circuit breaker yang dapat diumpamakan sebagai dua elektroda dengan dimensi luas yang berbeda. Dalam perhitungan probabilitas terjadinya tegangan tembus dapat digunakan fungsi distribusi normal (gaussian) dengan menggunakan dasar hukum perbesaran luas elektroda (enlargement law). Pada penelitian ini akan diuraikan tentang pengaruh perbesaran luas elektroda terhadap karakteristik tegangan tembus menggunakan sumber tegangan AC (Alternating Current). Metode penelitian yang digunakan adalah dengan mengambil data melalui pengujian tegangan tembus dan arus bocor di Laboratorium Tegangan Tinggi, Departemen Teknik Elektro, Fakultas Teknik, Universitas Brawijaya serta melakukan simulasi distribusi medan listrik pada setiap variasi perbesaran elektroda a, 2a, 3a, 4a, dan 5a menggunakan software FEMM 4.2. Variasi perbesaran luas elektroda a, 2a, 3a, 4a, dan 5a diuji tegangan tembus sebanyak 40 kali pemberian tegangan menggunakan metode Up and Down, dengan tegangan koreksi sebesar 1,5 kV. Pengujian arus bocor pada setiap perbesaran luas elektroda menggunakan sumber tegangan tinggi AC dengan variasi tegangan 5 kV, 10 kV, dan 15 kV. Hasil yang didapatkan dalam penelitian ini yaitu adanya pengaruh perbesaran luas elektroda terhadap karakteristik tegangan tembus dan arus bocor. Dimana semakin besar perbesaran luas elektroda maka probabilitas terjadinya tembus akan semakin besar pada tegangan dengan nilai yang sama, kelima variasi perbesaran memiliki tingkat homogenitas yang berbeda, serta tingkat arus bocor yang semakin besar atau linier dengan tingkat perbesaran luas elektroda.

English Abstract

Breakdown voltage events often occur as a failure of the insulation system in electrical equipment, whether in liquid dielectrics in the form of oil or gas dielectrics in the form of air. An example of the breakdown voltage phenomenon in an electric power system such as a substation is the breakdown voltage between two contacts/conductors of a circuit breaker (CB) or transformer in a substation. The difference in the dimensions of the area of the two contacts/conductors of the circuit breaker influences the distribution of the electric field around the contacts so that it can influence the probability of a breakdown voltage occurring between the two contacts of the circuit breaker which can be likened to two electrodes with different dimensions. In calculating the probability of a breakdown voltage occurring, the Gaussian distribution function can be used based on the law of electrode area enlargement (enlargement law). In this research, we will describe the effect of enlarging the electrode area on the characteristics of the breakdown voltage using an AC (Alternating Current) voltage source. The research method used is by taking data through testing breakdown voltage and leakage current at the High Voltage Laboratory, Department of Electrical Engineering, Faculty of Engineering, Brawijaya University and simulating the distribution of the electric field at each variation of electrode magnification a, 2a, 3a, 4a, and 5a using FEMM 4.2 software. Variations in magnification of the area of electrodes a, 2a, 3a, 4a, and 5a were tested for breakdown voltage 40 times using the Up and Down method, with a correction voltage of 1.5 kV. Leakage current testing at each enlarged electrode area uses a high voltage AC source with voltage variations of 5 kV, 10 kV, and 15 kV. The results obtained in this research are the influence of increasing the electrode area on the characteristics of the breakdown voltage and leakage current. Where the greater the magnification of the electrode area, the greater the probability of a breakdown occurring at a voltage of the same value, the five variations of magnification have different levels of homogeneity, and the level of leakage current which is greater is linear with the level of magnification of the electrode area. Keyword

Item Type: Thesis (Sarjana)
Identification Number: 0524070032
Uncontrolled Keywords: breakdown, perbesaran luas, probabilitas tembus, arus bocor
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: Unnamed user with username nova
Date Deposited: 12 Jun 2024 07:00
Last Modified: 12 Jun 2024 07:00
URI: http://repository.ub.ac.id/id/eprint/219883
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
Aulia Angkasa.pdf
Restricted to Registered users only

Download (3MB)

Actions (login required)

View Item View Item