Abstract

PT PLN (Persero) adalah salah satu BUMN yang bertanggung jawab atas manajemen kelistrikan di Indonesia. PLN memainkan peran penting dalam menyediakan layanan listrik kepada masyarakat melalui pembangkitan, penyaluran, pendistribusian, dan penjualan. Pada PT PLN (Persero) ULP Kangean, tercatat 33.737 pelanggan dengan daya tersambung sebesar 2.278.050 VA. Namun terdapat selisih antara jumlah energi yang terjual dengan jumlah energi yang dikeluarkan selama periode tersebut. Dua komponen utama, yaitu komponen teknis dan non-teknis, merupakan dua faktor atas penurunan energi tersebut. Metode Failure Mode and Effect Analysis (FMEA) digunakan dalam penelitian ini untuk menemukan penyebab susut energi listrik. Analisis data yang dilakukan dari bulan Januari hingga September 2022 menunjukkan bahwa Jaringan Tegangan Rendah (JTR) merupakan penyebab utama dari susut energi listrik pada PT PLN (Persero) ULP Kangean. Terdapat sejumlah kegagalan dalam JTR, di mana kerusakan pada penghantar listrik merupakan salah satu penyumbang nilai Residual Risk Priority Number (RPN) tertinggi, yaitu 23,1 atau sebesar 31,37%. Di mana kesalahan ini menjadi perhatian utama dalam upaya perbaikan dan pengendalian susut energi. Studi ini memberikan wawasan yang bermanfaat tentang sumber utama susut energi di PT PLN (Persero) ULP Kangean, dan memungkinkan penerapan tindakan yang lebih cermat dan efisien untuk meningkatkan efisiensi distribusi energi listrik dan mengatasi kegagalan yang dapat menyebabkan susut energi.

English Abstract

PT PLN (Persero) is one of the state-owned enterprises responsible for managing electricity in Indonesia. PLN plays a crucial role in providing electricity services to the community through generation, distribution, and sales. At PT PLN (Persero) ULP Kangean, there are 33,737 customers with a connected load of 2,278,050 VA. However, there is a discrepancy between the amount of energy sold and the amount of energy issued during this period. Two main components, namely technical and non-technical components, are the two factors behind this energy loss. The Failure Mode and Effect Analysis (FMEA) method is used in this study to identify the causes of electrical energy loss. Data analysis conducted from January to September 2022 shows that the Low Voltage Network (JTR) is the main cause of electrical energy loss at PT PLN (Persero) ULP Kangean. There are several failures in the JTR, where damage to the electrical conductors is one of the contributors to the highest Residual Risk Priority Number (RPN), namely 23.1 or 31.37%. This error is a major concern in efforts to repair and control energy loss. This study provides valuable insights into the main sources of energy loss at PT PLN (Persero) ULP Kangean, and enables the implementation of more precise and efficient actions to improve the efficiency of electricity distribution and address failures that can cause energy loss.

Item Type: Thesis (Sarjana)
Identification Number: 0524070130
Uncontrolled Keywords: Susut Energi Listrik, PT PLN (Persero) ULP Kangean, FMEA, JTR, Penghantar Listrik
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: soegeng sugeng
Date Deposited: 13 May 2024 02:14
Last Modified: 13 May 2024 02:14
URI: http://repository.ub.ac.id/id/eprint/219029
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
Adnan Gumintang.pdf
Restricted to Registered users only

Download (4MB)

Actions (login required)

View Item View Item