Nabalah, Dimas Fariz and Dr. Eng. Fitra Abdurrachman Bachtiar, S.T., M.Eng. and Barlian Henryranu Prasetio, S.T., M.T., Ph.D. (2024) Monitoring Respon Fisiologis Pengguna E-Learning Selama Sesi Pembelajaran Menggunakan Website. Sarjana thesis, Universitas Brawijaya.
Abstract
Proses belajar mengajar merupakan suatu interaksi timbal balik antara guru dan murid dengan tujuan mendapatkan perubahan dari apa yang tidak dimengerti menjadi mengerti. Metode pembelajaran sendiri ada 2 (dua) yaitu Teacher Centered Learning dan Student Centered Learning . Metode pembelajaran Student Centered Learning dengan sarana berupa e-learning pada pelaksanaannya tidak dilakukan monitor secara langsung oleh guru, sehingga dapat berpengaruh terhadap kesuksesan murid, karena dapat menimbulkan stres dan kecemasan. Salah satu cara agar kondisi murid tetap termonitoring adalah menggunakan monitoring fisiologis menggunakan sistem yang mengirimkan sinyal sehingga nantinya dapat diakuisisi menjadi data dalam bentuk numerik. Pada penelitian ini, sensor yang digunakan adalah sensor MAX30102, sensor MLX90614, dan sensor Galvanic Skin Response (GSR) sebagai sistem yang dapat mengukur tingkat denyut nadi, kadar oksigen, konduktansi kulit, serta tingkat suhu dari murid yang tengah belajar. Pada penelitian ini digunakan metode kuantitatif dengan akuisisi sinyal biometrik sebagai metode pengambilan data. Akuisisi sinyal dilakukan menggunakan perangkat keras mikrokontroler berupa ESP32 setelah melewati pembacaan dari sensor, data yang telah didapatkan kemudian dikirimkan menggunakan WiFi ke website Thingspeak untuk ditampilkan dalam bentuk grafik. Pengujian penelitian ini dilakukan terhadap murid dengan rentang usia 17-24 tahun, dan berada pada semester 1 hingga 8 dalam perkuliahan. Hasil yang didapatkan setelah melakukan pengujian dan dilakukan evaluasi menggunakan metode Z-Score adalah tidak ditemukannya anomali terhadap hasil data monitoring fisiologis, meskipun terdapat hasil yang tidak stabil akibat penggunaan sensor yang bersamaan. Kendati demikian, hasil yang didapat dari penelitian ini bahwa respon fisiologis pengguna e-learning adalah normal dan tidak normal, dengan data rata-rata denyut nadi adalah 84,1 Bpm normal, rata-rata kadar oksigen adalah 81,63 % tidak normal, rata-rata konduktansi kulit adalah 4,52 μS tidak normal, dan rata-rata suhu tubuh adalah 36,09 °C normal.
English Abstract
The process of teaching learning is a mutual interaction between teacher and student in order to get a change from what is not understood to understanding. The method of learning alone is two there is Teacher Centered Learning and Student Centered Learning. Student Centered Learning methods with the means of e-learning in the accomplishment are not monitored directly by teachers, and thus can influence student success, as it can cause stress and anxiety. One way the student's condition remains monitored is through physiological monitoring through systems that transmit signals so that it can be acquired into numerical data eventually. In this study, the sensors used are MAX30102, MLX90614 sensors, and Galvanic Skin Response (GSR) sensors as systems that account for pulse rates, oxygen levels, skin conduction, and temperature levels of students while studying. In this study, using a quantitative method with biometric signal acquisition as a data retrieval method. The acquisition of signals is done using a microcontroller hard device of ESP32 after going through the reading of the sensors, the data obtained is then sent using WiFi to the website Thingspeak for graphic viewing. The study was done on students of a 17-24 year age span, and was in 1st to 8th semester. Results obtained after testing and evaluation using the Z-Score method were found no anomalies in the physiological monitoring data, although there were unstable results from the simultaneous use of sensors. Nevertheless, the results from this study that users' physiological response from e-learning is normal and abnormal, with data the average pulse rate is 84.1 Bpm normal, the average oxygen level is 81.63% abnormal, the average skin conductance is 4.52 μS abnormal, and The average body temperature is 36.09 °C, normal.
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | 0524150166 |
Uncontrolled Keywords: | Monitoring, MAX30102, ESP32, Galvanic Skin Response (GSR), MLX90614-Monitoring, MAX30102, ESP32, Galvanic Skin Response (GSR), MLX90614 |
Divisions: | Fakultas Ilmu Komputer > Teknik Komputer |
Depositing User: | Sugeng Moelyono |
Date Deposited: | 27 Feb 2024 07:41 |
Last Modified: | 27 Feb 2024 07:41 |
URI: | http://repository.ub.ac.id/id/eprint/216043 |
![]() |
Text (DALAM MASA EMBARGO)
Dimas Fariz Nabalah.pdf Restricted to Registered users only Download (2MB) |
Actions (login required)
![]() |
View Item |