Perbandingan Hasil Ukur Tekanan Darah Lansia Hipertensi Menggunakan Sfigmomanometer Aneroid dan Digital di Wilayah Kerja Puskesmas Dinoyo Kota Malang

Zakia, - and Dr. Ns. Kumboyono, S.Kep., M.Kep., Sp.Kom and Ns. Akhiyan Hadi Susanto, S.Kep., M.Biomed (2023) Perbandingan Hasil Ukur Tekanan Darah Lansia Hipertensi Menggunakan Sfigmomanometer Aneroid dan Digital di Wilayah Kerja Puskesmas Dinoyo Kota Malang. Sarjana thesis, Universitas Brawijaya.

Abstract

Kesalahan pengukuran tekanan darah, dapat berakibat fatal pada penegakan diagnosis dan klasifikasi tekanan darah, baik itu meningkatkan positif palsu, maupun negatif palsu, pengukuran tekanan darah yang valid juga merupakan salah satu indikator penting manajemen kesehatan penderita hipertensi. Penelitian ini bertujuan untuk mengetahui perbedaan hasil ukur tekanan darah lansia hipertensi menggunakan sfigmomanometer aneroid dan digital di wilayah kerja Puskesmas Dinoyo Kota Malang. Metode penelitian yang digunakan yaitu pra-experimental dengan pendekatan post-test only design. Jumlah sampel sebanyak 70 responden berusia di > 60 tahun, sampel di ambil dengan teknik accidental sampling. Pengambilan data menggunakan sfigmomanometer aneroid dan digital sesuai kriteria inklusi dan ekslusi. Uji perbedaan tekanan darah menggunakan Mann-Whitney. Hasil penelitian menunjukkan bahwa tidak terdapat perbedaan hasil ukur tekanan darah pada lansia hipertensi menggunakan sfigmomanometer aneroid dan digital, dengan nilai p.value > 0,05. Berdasarkan hasil penelitian, dapat disimpulkan bahwa sfigmomanometer aneroid dapat menggantikan pengukuran sfigmomanometer digital satu sama lain, dikarenakan tidak adanya perbedaan hasil ukur tekanan darah antara kedua alat.

English Abstract

Blood pressure measurement errors can have fatal consequences for the diagnosis and classification of blood pressure, whether it increases false positives or false negatives, valid blood pressure measurements are also an important indicator of the health management of hypertension sufferers. This study aims to determine the differences in blood pressure measurement results for hypertensive elderly people using aneroid and digital sphygmomanometers in the working area of the Dinoyo Health Center, Malang City. The research method used was pre-experimental with a post-test only design approach. The total sample was 70 respondents aged > 60 years, samples were taken using accidental sampling technique. Data were collected using aneroid and digital sphygmomanometers according to inclusion and exclusion criteria. Test for differences in blood pressure using Mann-Whitney. The results of the study showed that there was no difference in blood pressure measurement results in hypertensive elderly using aneroid and digital sphygmomanometers, with a p.value > 0.05. Based on the research results, it can be concluded that an aneroid sphygmomanometer can replace digital sphygmomanometer measurements with each other, because there is no difference in blood pressure measurement results between the two devices.

Item Type: Thesis (Sarjana)
Identification Number: 0523160146
Uncontrolled Keywords: Perbedaan Tekanan Darah, Sfigmomanometer Aneroid dan Digital, Pengukuran Tekanan Darah-Differences in Blood Pressure, Aneroid and Digital Sphygmomanometers, Blood Pressure Measurement
Divisions: Fakultas Ilmu Kesehatan > Ilmu Keperawatan, Fakultas Ilmu Kesehatan
Depositing User: soegeng sugeng
Date Deposited: 06 Feb 2024 07:33
Last Modified: 06 Feb 2024 07:33
URI: http://repository.ub.ac.id/id/eprint/214736
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
Zakia.pdf
Restricted to Registered users only

Download (7MB)

Actions (login required)

View Item View Item