Uji Diagnostik Vibratip Dan Garpu Tala 128 Hz Dalam Mendeteksi Neuropati Perifer Pada Kaki Diabetik Di Rumah Sakit Lavalette Kota Malang.

Laksmi, Rita Widya and Dr. Ns. Heri Kristianto, S.Kep., M.Kep.,Sp.Kep.MB and Dr. Nurul Muslihah, SP., M.Kes (2024) Uji Diagnostik Vibratip Dan Garpu Tala 128 Hz Dalam Mendeteksi Neuropati Perifer Pada Kaki Diabetik Di Rumah Sakit Lavalette Kota Malang. Magister thesis, Universitas Brawijaya.

Abstract

Diabetes mellitus merupakan penyakit metabolik yang dapat menyebabkan komplikasi berupa neuropati perifer kaki diabetik. Penilaian klinis neuropati tersebut dapat dilakukan dengan menguji sensasi getaran menggunakan garpu tala 128 Hz, vibratip, dan biothesiometer. Biothesiometer menjadi gold standard dengan sensitivitas 80% dan spesifisitas 99%. Penelitian ini bertujuan untuk mengidentifikasi nilai diagnostik vibratip garpu tala 128 Hz. Metode penelitian ini menggunakan pendekatan cross sectional dengan sampel sebanyak 140 orang melalui metode simple random sampling. Sensitivitas, spesifisitas, nilai duga positif dan negatif serta akurasi dihitung melalui tabel kontingensi 2x2. Hasil analisis didapatkan bahwa sensitivitas vibratip dan garpu tala 128 Hz sebesar 80,5% dan 37,35%. Spesifisitas vibratip dan garpu tala 128 Hz sebesar 91% dan 94,35%. Nilai duga positif vibratip dan garpu tala 128 Hz sebesar 85,5% dan 78,7%. Nilai duga negatif vibratip dan garpu tala 128 Hz sebesar 89% dan 71,95. Akurasi vibratip dan garpu tala 128 Hz sebesar 88% dan 73,15%. Kesimpulan penelitian ini adalah vibratip memiliki sensitivitas, akurasi, nilai duga positif dan negatif yang lebih tinggi dari garpu tala 128 Hz, serta sebanding dengan biothesiometer. Vibratip memiliki spesifisitas yang sebanding dengan garpu tala 128 Hz dan biothesiometer. Saran dari hasil penelitian ini adalah vibratip dapat digunakan untuk mendeteksi neuropati perifer pada pasien diabetes tipe 2 yang belum memiliki komplikasi kaki diabetik. Garpu tala 128 Hz dapat digunakan untuk mendeteksi pasien yang tidak mengalami neuropati perifer kaki diabetik. Biothesiometer dapat digunakan untuk mendeteksi neuropati perifer kaki diabetik pada pasien diabetes tipe 2 yang sudah mengalami penebalan kulit atau kalus.

English Abstract

Diabetes mellitus is a metabolic disease that can cause complications in the form of peripheral neuropathy of the diabetic foot. Clinical assessment of neuropathy can be done by testing vibration sensation using a 128 Hz tuning fork, vibrating tip, and biothesiometer. The biothesiometer is the gold standard with a sensitivity of 80% and a specificity of 99%. This study aims to identify the diagnostic value of a 128 Hz tuning fork vibration. This research method uses a cross sectional approach with a sample of 140 people using a simple random sampling method. Sensitivity, specificity, positive and negative predictive values and accuracy are calculated using a 2x2 contingency table. The results of the analysis showed that the sensitivity of the 128 Hz vibrating fork and tuning fork was 80.5% and 37.35%. The specificity of the 128 Hz vibration tip and tuning fork is 91% and 94.35%. The positive predictive value of the 128 Hz vibration tip and tuning fork was 85.5% and 78.7%. The negative predictive values of the 128 Hz vibration tip and tuning fork were 89% and 71.95. The accuracy of the 128 Hz vibrating fork and tuning fork is 88% and 73.15%. The conclusion of this study is that the vibratip has higher sensitivity, accuracy, positive and negative predictive values than a 128 Hz tuning fork, and is comparable to a biothesiometer. Vibratips have comparable specificity to 128 Hz tuning forks and biothesiometers. The suggestion from the results of this study is that the vibratip can be used to detect peripheral neuropathy in type 2 diabetes patients who do not yet have diabetic foot complications. A 128 Hz tuning fork can be used to detect patients who do not have diabetic foot peripheral neuropathy. Biothesiometers can be used to detect peripheral neuropathy of the diabetic foot in type 2 diabetes patients who have experienced thickening of the skin or callus.

Item Type: Thesis (Magister)
Identification Number: 0424160003
Uncontrolled Keywords: biothesiometer; diabetes; garpu tala 128 Hz; neuropati perifer; vibratip-biothesiometer; diabetes; 128 Hz tuning fork; peripheral neuropathy; vibratip
Divisions: S2/S3 > Magister Keperawatan, Fakultas Kedokteran
Depositing User: soegeng sugeng
Date Deposited: 13 Feb 2024 07:47
Last Modified: 13 Feb 2024 07:47
URI: http://repository.ub.ac.id/id/eprint/214592
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
Rita Widya Laksmi.pdf
Restricted to Registered users only

Download (8MB)

Actions (login required)

View Item View Item