Evaluasi Kinerja Seismik Bangunan 5 Lantai dengan SNI 1726:2012 dan SNI 1726:2019 (Studi Kasus : Gedung Pascasarjana FAPET UB)

Arilia, Luthfiyah Putri and Dr. Eng. Achfas Zacoeb, ST., MT and Dr. Ir. Wisnu Murti, MT. (2021) Evaluasi Kinerja Seismik Bangunan 5 Lantai dengan SNI 1726:2012 dan SNI 1726:2019 (Studi Kasus : Gedung Pascasarjana FAPET UB). Sarjana thesis, Universitas Brawijaya.

Abstract

Hampir setiap tahunnya terjadi gempa bumi di berbagai daerah di Indonesia. Menurut catatan dari BMKG, sepanjang tahun 2021 telah terjadi 10.570 gempa bumi di Indonesia, dengan 244 kali gempa bumi yang berkekuatan diatas 5 dan diantaranya 26 gempa bumi bersifat merusak. Gempa bumi, seperti halnya bencana lainnya tidak dapat diprediksi, tapi bisa dikurangi dampaknya, mengharuskan perencanaan struktur bangunan dilakukan dengan baik dan memenuhi kaidah serta berdasarkan peraturan terkini. Salah satu konsep yang dewasa ini sedang banyak digunakan adalah Performance based seismic design dengan tingkat kinerja yang menjadi fokus utama. Dibutuhkan analisis nonlinear untuk mengetahui kinerja struktur saat menerima beban gempa. Salah satu cara analisis nonlinear yang dapat digunakan adalah analisis pushover dengan bantuan software SAP2000 V20. Peraturan perencanaan bangunan tahan gempa bumi yang terbaru saat ini adalah SNI 1726:2019. Gedung pascasarjana FAPET UB dibangun masih dengan perencanaan berdasarkan pada SNI 1726:2012 maka perlu diperhitungkan beban akibat gempa yang sesuai dengan peraturan yang berlaku. Pada penelitian ini struktur bangunan tersebut dianalisis kinerjanya berdasarkan SNI 1726:2012 dan SNI 1726:2019. Hasil evaluasi menggunakan analisis pushover pada Gedung Pascasarjana FAPET UB menunjukkan bahwa struktur yang dianalisis berdasarkan dengan SNI 1726:2012 memiliki simpangan maksimum untuk arah X sebesar 0.00681 m dan 0.0084 m untuk arah Y. Sedangkan untuk hasil analisis berdasarkan SNI 1726:2019 didapatkan nilai simpangan total maksimum untuk arah x sebesar 0.00885 m dan arah y sebesar 0.01 m. Dari nilai yang didapatkan tersebut dapat disimpulkan berdasarkan ATC-40 dengan SNI 1726:2012 untuk arah X dan Y struktur berada pada kondisi tingkat kinerja Immediate Occupancy (IO), dan dengan dengan SNI 1726:2019 untuk arah X berada pada kondisi tingkat kinerja Immediate Occupancy (IO) dan arah Y pada tingkat kinerja Damage Control.

English Abstract

Almost in every year earthquakes happened in various regions in Indonesia. According to the data from BMKG, in 2021 there have been a total of 10,570 earthquakes in Indonesia, with 244 earthquakes have above 5 Magnitudes and 26 of them classified as destructive earthquakes. Earthquakes, like other disasters, cannot be predicted, but their impact can be reduced. The building structure must be designed properly and comply with the rules and based on the latest regulations. One of the concepts that is currently being widely used is Performance based seismic design with performance levels as the main concern. Nonlinear analysis is needed to determine the performance of the structure when receiving earthquake loads. One of the nonlinear analysis methods that can be used is pushover analysis, which in this study was done with the help of SAP2000 V20 as analysis software. The most recent regulation for earthquake resistance building is SNI 1726:2019. FAPET UB postgraduate building was designed based on the previous regulation SNI 1726:2012, so it is necessary to calculate the load due to the earthquake loads in accordance with applicable regulations. In this study, the performance of the structure is being analyzed based on SNI 1726:2012 and SNI 1726:2019. The evaluation result of FAPET UB postgraduate building using pushover analysis show that the structure that has been analyzed using SNI 1726:2012 has maximum total drift in the X direction is 0.00681 m and 0.0084 m. In Y direction. Whereas the result using SNI 1726:2019 shows the maximum total drift in X direction is 0.00885 m and in Y direction is 0.01 m. From the values obtained, it can be concluded that with SNI 1726:2012 for the X and Y directions the structure is in the condition of the Immediate Occupancy (IO) performance level, and with SNI 1726:2019 for the X direction it is in the condition of the performance level (IO). and Y direction on the Damage Control performance level.

Item Type: Thesis (Sarjana)
Identification Number: 052307
Uncontrolled Keywords: gempa bumi, pushover, SNI 1726:2012, SNI 1726:2019, tingkat kinerja, SAP2000-earthquake, pushover, SNI 1726:2012, SNI 1726:2019, performance level, SAP2000
Divisions: Fakultas Teknik > Teknik Sipil
Depositing User: Emy Sukartini
Date Deposited: 23 Jan 2024 07:19
Last Modified: 23 Jan 2024 07:19
URI: http://repository.ub.ac.id/id/eprint/213378
[thumbnail of Dalam masa EMBARGO] Text (Dalam masa EMBARGO)
Luthfiyah Arilia.pdf
Restricted to Registered users only until 31 December 2024.

Download (11MB)

Actions (login required)

View Item View Item