Aprillia, Indah Ayu and Dr. Eng. Achfas Zacoeb, ST., MT. and Prof. Dr. Ir. Agoes Soehardjono, MS. (2022) Evaluasi Kinerja Seismik Bangunan Eksisting dengan Metode Pushover Berdasarkan SNI 1726:2019 (Studi Kasus : GPT II FKUB-RSSA). Sarjana thesis, Universitas Brawijaya.
Abstract
Permasalahan kekuatan pada bangunan gedung bertingkat di Indonesia merupakan permasalahan yang sering terjadi terutama terhadap bencana gempa bumi. Pada periode 2021, menurut BMKG Karangkates Malang telah tercatat 44 kejadian gempa bumi dengan terjadi 3 peristiwa gempa bumi yang signifikan di Jawa Timur. Dengan terjadinya gempa bumi yang signifikan ini mengakibatkan kerusakan dan keruntuhan pada beberapa bangunan, terutama bangunan bertingkat. Dengan adanya gempa bumi yang sering terjadi di Kota Malang, maka perencanaan kontruksi di Indonesia harus mengacu pada Standar Nasional Indonesia yang diterbitkan oleh Badan Standardisasi Nasional. Untuk SNI gempa sendiri telah diperbarui sesuai dengan riset dan penelitian terbaru yakni SNI 1726:2019. Dimana SNI 1726:2019 membahas mengenai tata cara perencanaan ketahanan gempa untuk struktur bangunan gedung dan nongedung sebagai revisi dari SNI 1726:2012. Hal ini menjadi faktor yang mendasari perlunya melakukan evaluasi pada GPT II FKUBRSSA ini dengan menggunakan standar pembebanan gempa yang terbaru yang telah disesuaikan dengan kondisi kegempaan di wilayah Indonesia. Dalam analisis ini, dilakukan dengan menggunakan metode pushover yang dianalisis dengan program SAP2000, dimana beban yang dimasukkan dalam pemodelan adalah beban mati, beban hidup, dan beban gempa serta beberapa parameternya. Hasil yang diperoleh dalam analisis dengan meninjau terhadap ketentuan SNI 1726:2019 dan ATC-40 adalah besarnya gaya geser dan perpindahan atap, kriteria dan kemampuan struktur, serta mekanisme keruntuhan dari struktur bangunan. Hasil dari analisis statik didapatkan nilai partisipasi massa struktur telah mencapai 100% dari kedua arah, sedangkan hasil dari analisis dinamik partisipasi massa juga telahmencapai nilai lebih dari 90%. Dan diperoleh nilai-nilai pada performance point yakni nilai gaya dasar efektif arah X=140691,96 kg dan arah Y= 151686,05 kg, nilai simpangan atap arah X= 0,056 dan arah Y= 0,001065m, Periode efektif arah X= 1,748 dt dan arah Y= 1,629, dan nilai redaman efektif dari arah x dan y diperoleh nilai yang sama yakni 0,05%. Pada analisis didapatkan juga hasil mekanisme sendi plastis terjadi pada step 3 untuk arah X dan step 1 untuk arah Y pada level B yang terus meningkat hingga iterasi berhenti dilakukan setelah mencapai step ke 11 pada level C untuk arah X yang didapatkan gaya lateral maksimum 1122103,1 kg dengan displacement yang terjadi 0,719395m dan step ke 53 untuk arah Y yang didapatkan gaya lateral maksimum 379759,3 kg dengan displacement yang terjadi 0,074832 dikarenakan elemen struktur sudah tidak mampu menahan gaya yang diberikan. Dengan ini diperoleh tingkat kinerja dari struktur GPT II FKUB-RSSA tergolong kategori immediate Occupancy (IO)
English Abstract
The problem of strength in high-rise buildings in Indonesia is a problem that often occurs when facing earthquakes. In the 2021 period, according to Indonesian Agency for Meteorological, Climatological, and Geophysics (BMKG) Karangkates Malang, 44 earthquakes have been recorded with 3 significant earthquakes in East Java. With the occurrence of this significant earthquake resulted in damage and collapse of several buildings, especially on high-rise buildings. With earthquakes that often occur in Malang City, construction planning in Indonesia must refer to the Indonesian National Standards (SNI) issued by the National Standardization Agency. The provisions for the earthquake itself have been updated with the latest research, namely SNI 1726:2019 where it discusses the procedures for planning earthquake resistance for building and non-building structures as a revision of SNI 1726:2012. This is the main factor for the need to evaluate GPT II FKUB-RSSA Building using the latest earthquake loading standards that have been adapted to seismic conditions in Indonesia. The analysis is carried out using the pushover method which is analyzed with SAP2000 software, where the input loads in the modeling are dead loads, live loads, and earthquake loads, as well as some of their parameters. The results that will be obtained in the analysis by using the provisions of SNI 1726:2019 and ATC-40 are the magnitude of the shear force and displacement of the roof, the criteria and capabilities of the structure, as well as the collapse mechanism of the building structure.The results of the static analysis shows that the value of the mass participation of the structure has reached 100% of both directions, while the results of the dynamic analysis of mass participation have also reached a value of more than 90%. Performance point are also obtained, namely the value of the effective basic force of the X direction = 140691.96 kg and the direction of Y = 151686.05 kg, the value of the roof deviation in the X direction = 0.056 and the direction of Y = 0.001065m, The effective period of the X direction = 1.748 dt and the direction Y = 1.629, and the effective damping value of the x and y directions obtained the same value of 0.05%. The results of the plastic joint mechanism were also obtained at step 3 for direction X and step 1 for direction Y at level B which continued to increase until iteration stopped after reaching step 11 at level C. Analysis also shows that the maximum lateral force in the x direction is 1122103.1 kg with a displacement of 0.719395 m at the step 11, and the maximum lateral force in the Y direction is 379759.3 kg with a displacement of 0.074832 at the step 53, due to the structure is no longer able to withstand the applied force. With this, the performance level of GPT II FKUB-RSSA Building is classified as Immediate Occupancy (IO) category.
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | 052307 |
Uncontrolled Keywords: | gempa bumi, pushover, tingkat kinerja, sendi plastis, SNI 1726:2019- earthquake, pushover, performance level, plastic hinges, SNI 1726:2019 |
Divisions: | Fakultas Teknik > Teknik Sipil |
Depositing User: | Unnamed user with email y13w@ub.ac.id |
Date Deposited: | 19 Jan 2024 09:16 |
Last Modified: | 19 Jan 2024 09:16 |
URI: | http://repository.ub.ac.id/id/eprint/212781 |
![]() |
Text (DALAM MASA EMBARGO)
INDAH AYU APRILLIA.pdf Restricted to Registered users only until 31 December 2024. Download (3MB) |
Actions (login required)
![]() |
View Item |