Abstract

DAS Bendungan Manikin terletak di Kabupaten Kupang dan memiliki luas sebesar 45,63 km2. Kabupaten Kupang mempunyai iklim yang tidak menentu karena dalam setahun musim kemarau relatif lebih panjang dibandingkan musim hujan. Kondisi yang tidak menentu ini menjadi permasalahan umum di daerah Kabupaten Kupang. Curah hujan yang tinggi saat musim hujan dapat menyebabkan masalah banjir yang sangat merugikan dari segi materiil maupun kesehatan masyarakat. Salah satu upaya yang dilakukan yaitu pembangunan tampungan air hujan seperti bendungan. Dalam perencanaannya dibutuhkan analisis debit banjir rancangan sebagai patokan untuk dimensi suatu bangunan air, agar aman terhadap curah hujan tinggi dan tidak terjadi kerusakan akibatnya. Tujuan dari penelitian ini yaitu untuk menganalisis hujan rancangan yang terjadi menggunakan Distribusi Gumbel, Log Pearson III, dan Log Normal dan untuk menganalisis debit banjir rancangan menggunakan HSS Nakayasu, HSS SCS, dan HSS Gama-I pada kala ulang 2th, 5th, 10th, 25th, 50th, 100th, 200th, dan 1000th. Sebelum dilakukan analisis distribusi frekuensi, dilakukan uji homogenitas, uji ketiadaan tren (Spearman, MannWhitney, Cox Stuart), uji stasioner, uji persistensi, dan uji outlier untuk mengetahui kelayakan data. Analisis hujan rata-rata daerah menggunakan metode aljabar. Perhitungan nilai PMP menggunakan metode Hersfield. Pemilihan distribusi hujan rancangan berdasarkan uji chi-square dan uji smirnov-kolmogorov serta sifat distribusinya. Sedangkan pemilihan metode HSS untuk debit banjir rancangan berdasarkan hasil RMSE, NSE, koefisien korelasi, dan uji kesalahan relatif. Hasil dari uji homogenitas, uji ketiadaan tren (Spearman, Mann-Whitney, Cox Stuart), uji stasioner, dan uji persistensi menunjukkan bahwa data pada Stasiun Baun dan Stasiun Oeletsala layak dan dapat digunakan untuk analisis selanjutnya. Berdasarkan uji outlier, data tahun 2021 di Stasiun Oeletsala melewati batas atas dan tidak digunakan di perhitungan selanjutnya. Perhitungan hujan rancangan menggunakan distribusi Log Pearson III karena pada uji chi-square dan uji smirnov kolmogorov menunjukkan bahwa distribusi tersebut dapat diterima. Selain itu distribusi Log Pearson III juga dipilih, karena sifatnya yang fleksibel. Pada Analisis debit banjir rancangan, metode yang mendekati kondisi DAS, yaitu xvi HSS Nakayasu. Hasil validasi menunjukkan metode HSS Nakayasu mempunyai nilai RMSE, NSE, dan uji kesalahan relatif terkecil serta mempunyai korelasi yang kuat dengan debit banjir terukur.

English Abstract

The Manikin Dam watershed is located in Kupang Regency and has an area of 45.63 km2. Kupang Regency has an erratic climate because the dry season is relatively longer than the rainy season. This unpredictable condition is a common problem in Kupang Regency. High rainfall during the rainy season can cause flooding problems that are very detrimental in terms of material and public health. One of the efforts made is the construction of rainwater reservoirs such as dams. In planning, it is necessary to analyze the design flood discharge as a benchmark for the dimensions of a water building, so that it is safe against high rainfall and no damage occurs as a result. The purpose of this research is to analyze the design rainfall that occurs using the Gumbel Distribution, Log Pearson III, and Log Normal and to analyze the design flood discharge using HSS Nakayasu, HSS SCS, and HSS Gama-I at 2th, 5th, 10th, 25th, 50th, 100th, 200th, and 1000th return times. Prior to frequency distribution analysis, homogeneity test, trendlessness test (Spearman, Mann-Whitney, Cox Stuart), stationary test, persistence test, and outlier test were conducted to determine data feasibility. Analysis of regional average rainfall using the algebraic method. Calculation of PMP value using Hersfield method. Selection of design rainfall distribution based on chi-square test and smirnovkolmogorov test as well as its distribution properties. While the selection of HSS method for design flood discharge is based on the results of RMSE, NSE, correlation coefficient, and relative error test. The results of the homogeneity test, trendlessness test (Spearman, Mann-Whitney, Cox Stuart), stationary test, and persistence test show that the data at Baun Station and Oeletsala Station are feasible and can be used for further analysis. Based on the outlier test, the 2021 data at Oeletsala Station exceeds the upper limit and is not used in further calculations. The calculation of design rainfall uses the Log Pearson III distribution because the chi-square test and Smirnov Kolmogorov test show that the distribution is acceptable. In addition, the Log Pearson III distribution was also chosen because of its flexibility. In the design flood discharge analysis, the method that approximates the watershed conditions is HSS Nakayasu. The validation results show that the Nakayasu HSS method has the smallest xviii RMSE, NSE, and relative error test values and has a strong correlation with the measured flood discharge.

Item Type: Thesis (Sarjana)
Identification Number: 052307
Uncontrolled Keywords: Curah hujan, Hidrograf, Debit Banjir, Daerah Aliran Sungai, Rainfall, Hydrograph, Flood Discharge, Watershed.
Divisions: Fakultas Teknik > Teknik Pengairan
Depositing User: Zainul Mustofa
Date Deposited: 11 Jan 2024 04:53
Last Modified: 11 Jan 2024 04:53
URI: http://repository.ub.ac.id/id/eprint/208299
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
Muhammad Irfan Ananta.pdf
Restricted to Registered users only until 31 December 2025.

Download (11MB)

Actions (login required)

View Item View Item