Pengaruh Variasi Tekanan Uap Ekstraksi Terhadap Kinerja Pembangkit Listrik Tenaga Uap Menggunakan Pemodelan GateCycle.

Jocom, Albertus Abisha Pinem and Dr. Eng. Lilis Yuliati,, ST., MT. and Winarto, ST., MT., Ph.D. (2023) Pengaruh Variasi Tekanan Uap Ekstraksi Terhadap Kinerja Pembangkit Listrik Tenaga Uap Menggunakan Pemodelan GateCycle. Sarjana thesis, Universitas Brawijaya.

Abstract

Energi Listrik merupakan salah satu kebutuhan utama pada masa ini dikarenakan sebagian besar kegiatan yang dilakukan manusia saat ini membutuhkan energi listrik. Kementrian Energi dan Sumber Daya Alam (ESDM) menyatakan bahwa pada tahun 2022 konsumsi listrik per kapita di Indonesia sebesar 1.173 kWh, meningkat 4,45% dari tahun 2021.Menurut Badan Pusat Statistik (2021), PLTU merupakan jenis pembangkit paling dominan di Indonesia dengan kapasitas 66% dari total pembangkitan listrik di Indonesia. Dikarenakan banyaknya PLTU di Indonesia, maka diperlukan siklus PLTU yang semakin efisien. Peningkatan efisiensi PLTU salah satunya dapat dilakukan dengan mengatur tekanan uap ekstraksi yang masuk ke setiap feedwater heater. Pengoptimalan kinerja feedwater heater dengan mengatur tekanan uap ekstraksi akan mengurangi penggunaan bahan bakar dan meningkatkan efisiensi siklus PLTU. Oleh karena itu tujuan dari penelitian ini adalah untuk mengetahui pengaruh perubahan tekanan uap ekstraksi terhadap kinerja dari PLTU Paiton Unit 1 menggunakan aplikasi simulasi Gatecycle. Variasi dilakukan dengan mengatur tekanan uap yang masuk ke feedwater heater sehingga temperature air yang keluar setiap feedwater heater memiliki peningkatan temperature yang konstan. Variasi lain juga dilakukan dengan menaikan serta menurunkan tekanan pada feedwater heater sebesar 4% dan 5%. Hasil menunjukkan dengan meningkatkan tekanan uap ekstraksi ke feedwater heater akan menyebabkan peningkatan temperature air yang keluar dari feedwater heater. Dengan menentukan dan menjaga temperatur air keluar feedwater heater memiliki kenaikan temperature yang konstan, maka akan menyebabkan pembagian kerja feedwater heater serta meningkatkan temperature air yang masuk ke economizer. Peningkatan temperature air masuk economizer akan mengakibatkan peningkatan efisiensi PLTU dan meningkatkan daya yang dihasilkan oleh PLTU, serta nilai heat rate yang rendah. Konsumsi bahan bakar yang dibutuhkan untuk menghasilkan daya operasional pun semakin rendah.

English Abstract

Electrical Energy is one of the main needs at this time because most of the activities carried out by humans today require electrical energy. The Ministry of Energy and Natural Resources (ESDM) states that in 2022 electricity consumption per capita in Indonesia will be 1,173 kWh, an increase of 4.45% from 2021. According to the Central Bureau of Statistics (2021), PLTU is the most dominant type of generator in Indonesia with capacity of 66% of the total electricity generation in Indonesia. Due to the large number of PLTUs in Indonesia, an increasingly efficient PLTU cycle is needed. One of the ways to increase the efficiency of PLTU is by adjusting the extraction steam pressure that enters each feedwater heater. Optimizing the performance of the feedwater heater by adjusting the extraction steam pressure will reduce fuel use and increase the efficiency of the PLTU cycle. Therefore the purpose of this study was to determine the effect of changes in extraction vapor pressure on the performance of PLTU Paiton Unit 1 using the Gatecycle simulation application. Variations are made by adjusting the steam pressure that enters the feedwater heater so that the temperature of the water that comes out of each feedwater heater has a constant temperature increase. Other variations are also carried out by increasing and decreasing the pressure in the feedwater heater by 4% and 5%. The results show that increasing the extraction steam pressure to the feedwater heater will cause an increase in the temperature of the water coming out of the feedwater heater. By determining and maintaining the temperature of the water leaving the feedwater heater having a constant temperature rise, it will cause the division of labor into the feedwater heater and increase the temperature of the water entering the economizer. An increase in the temperature of the water entering the economizer will result in an increase in the efficiency of the PLTU and an increase in the power generated by the PLTU, as well as a lower heat rate value. The fuel consumption needed to produce operational power is even lower.

Other obstract

-

Item Type: Thesis (Sarjana)
Identification Number: 0523070164
Uncontrolled Keywords: Extraction Steam Pressure, GateCycle, Efficiency, Heat rate, Net power
Subjects: 600 Technology (Applied sciences) > 621 Applied physics > 621.8 Machine engineering
Divisions: Fakultas Teknik > Teknik Mesin
Depositing User: Endang Susworini
Date Deposited: 21 Sep 2023 02:34
Last Modified: 21 Sep 2023 02:34
URI: http://repository.ub.ac.id/id/eprint/203110
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
ALBERTUS ABISHA PINEM JOCOM.pdf
Restricted to Registered users only until 31 December 2025.

Download (4MB)