Kontrol Kecepatan Motor DC Pompa Air R385 Pada Alat Pengontrol pH Air Kolam Ikan Menggunakan Fuzzy Logic Control Dengan Metode Mamdani,

Akbar, Bayu Rahmat and Goegoes Dwi Nusantoro, ST., MT, ST., MT. and Ir. Ali Mustofa, S.T., M.T., IPM. (2021) Kontrol Kecepatan Motor DC Pompa Air R385 Pada Alat Pengontrol pH Air Kolam Ikan Menggunakan Fuzzy Logic Control Dengan Metode Mamdani,. Sarjana thesis, Universitas Brawijaya.

Abstract

Motor Direct Current (DC) pada pompa air R385 yang terletak di alat kontrol pH air kolam berfungsi untuk menambahkan larutan asam atau basa ke kolam sehingga pH air kolam dapat berubah sesuai yang kita inginkan, menggerakan motor DC pada pompa air secara langsung dapat menyebabkan tidak akuratnya jumlah larutan yang ditambahkan. Pengontrolan kecepatan motor DC pada pompa air alat kontrol pH air kolam bertujuan agar jumlah larutan yang ditambahkan sesuai dengan yang dibutuhkan. Digunakan fuzzy logic control untuk mengurangi kesalahan larutan buffer yang ditambahkan pada alat kontrol pH air kolam. Fuzzy logic control yang digunakan adalah metode mamdani dengan beberapa tahap, yaitu fuzzifikasi, kaidah atur (Rule-Base) dan inferensi, dan defuzzifikasi. Metode fuzzifikasi yang digunakan adalah metode min-max sedangkan pada defuzzifikasi menggunakan metode center of gravity. Hasil dari respon secara keseluruhan sistem adalah jumlah larutan yang dikeluarkan sesuai dengan yang diinginkan.

English Abstract

The Direct Current (DC) motor on the water pump located in the pool water pH control device functions to add acid or alkaline solutions to the pool so that the pH of the pool water can change as we want, moving the DC motor on the water pump directly can cause inaccurate amounts solution added. Controlling the speed of the DC motor on the water pump, the pool water pH control device, aims to ensure that the amount of solution added is according to what is needed. Fuzzy logic control is used to reduce the error of the buffer solution added to the pool water pH controller. Fuzzy logic control used is the mamdani method with several stages, namely fuzzification, rule-base and inference, and defuzzification. The fuzzification method used is the min-max method, while the defuzzification method uses the center of gravity method. The result of the overall response of the system is the amount of solution released as desired.

Other obstract

-

Item Type: Thesis (Sarjana)
Identification Number: 0521070087
Uncontrolled Keywords: Kata Kunci: Fuzzy Logic Control, Alat Kontrol pH air, Sistem Pengontrolan Kecepatan Pompa.
Subjects: 600 Technology (Applied sciences) > 621 Applied physics > 621.3 Electrical, magnetic, optical, communications, computer engineering; electronics, lighting > 621.38 Electronics, communications engineering > 621.381 Electronics
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: yulia Chasanah
Date Deposited: 04 Nov 2021 06:51
Last Modified: 15 Jun 2022 03:46
URI: http://repository.ub.ac.id/id/eprint/186484
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
- BAYU RAHMAT AKBAR.pdf
Restricted to Registered users only until 31 December 2023.

Download (19MB)

Actions (login required)

View Item View Item