Pengaruh Variasi Letak Transduser pada Alat UPVT (Ultrasonic Pulse Velocity Test) terhadap Pengukuran Variasi Kedalaman Retak Beton

Rizqullah, Naufal Rafif (2021) Pengaruh Variasi Letak Transduser pada Alat UPVT (Ultrasonic Pulse Velocity Test) terhadap Pengukuran Variasi Kedalaman Retak Beton. Sarjana thesis, Universitas Brawijaya.

Abstract

Beton merupakan komponen utama struktural yang sering dijumpai pada beberapa pembangunan infrastruktur seperti gedung, jembatan, irigasi, bendungan,dan jalan. Namun sering dijumpai beragam permasalahan saat proses konstruksi maupun pasca konstruksi pada proyek – proyek di lapangan dan salah satunya keretakan pada beton yang dapat mengakibatkan melemahnya kekuatan struktur. Oleh karena itu, perlu dilakukan identifikasi kedalaman retak pada struktur agar dapat mengetahui perlakuan yang tepat untuk dilakukan pada struktur beton yang mengalami retak. Untuk mengidentifikasi kedalaman retak pada beton dapat menggunakan metode Non Destructive Test dan salah satunya dengan UPVT (Ultrasonic Pulse Velocity Test). Penelitian ini menggunakan benda uji beton tidak bertulang dengan variasi kedalaman retak 4 cm, 8 cm dan 12 cm. Penelitian ini dilakukan dengan mengidentifikasi variasi kedalaman retak tersebut dengan pengujian UPV menggunakan alat PUNDIT PL-200. Pengujian dilakukan dengan variasi perletakan transduser yang terdiri dari 5 cm, 10 cm, dan 15 cm. Hasil pengujian UPV menunjukkan bahwa terdapat pengaruh variasi perletakan transduser dan variasi kedalaman retak terhadap pembacaan kedalaman retak pada beton. Hal tersebut ditunjukkan dengan adanya perbedaan pada waktu transmisi gelombang dan hasil pembacaan. Hasil pembacaan pada beton dengan kedalaman retak 4 cm memiliki nilai kesalahan relatif terhadap nilai aktual terbesar yaitu sebesar 8,5 % pada jarak transduser 5 cm dan yang terkecil yaitu sebesar 0,5 % pada jarak transduser 15 cm. Beton dengan kedalaman retak 8 cm memiliki hasil pembacaan dengan nilai kesalahan relatif terhadap nilai aktual terbesar yaitu sebesar 46,5 % pada jarak transduser 5 cm dan yang terkecil yaitu sebesar 4 % pada jarak transduser 15 cm. Dan beton dengan kedalaman retak 12 cm memiliki hasil pembacaan dengan nilai kesalahan relatif terhadap nilai aktual terbesar yaitu sebesar 57,33 % pada jarak transduser 5 cm dan yang terkecil yaitu sebesar 0,17 % pada jarak transduser 15 cm. Sehingga dapat disimpulkan bahwa semakin kecil jarak antar transduser maka nilai yang dihasilkan pada hasil pembacaan semakin menjauhi nilai retak aktual. Hasil pengujian UPV pada penelitian ini juga menunjukkan bahwa semakin besar jarak perletakan transduser dan kedalaman retak maka semakin meningkat waktu transmisi gelombang yang dihasilkan

English Abstract

Concrete is the main structural component that is often found in several infrastructure developments such as buildings, bridges, irrigation, dams, and roads. However, various problems are often encountered during the construction and postconstruction processes on projects in the field and one of them is cracks in the concrete which can lead to the weakening of the strength of the structure. Therefore, it is necessary to identify the depth of cracks in the structure in order to find out the right treatment to be carried out on cracked concrete structures. To identify the depth of cracks in concrete can use the Non-Destructive Test method and one of them is the UPVT (Ultrasonic Pulse Velocity Test). This study used unreinforced concrete specimens with variations in crack depth of 4 cm, 8 cm, and 12 cm. This research was conducted by identifying the variation of the crack depth by UPV testing using the PUNDIT PL-200 tool. The test was carried out with variations in the placement of the transducer consisting of 5 cm, 10 cm, and 15 cm. The results of the UPV test show that there is an effect of variations in transducer placement and variations in crack depth on the reading of crack depth in concrete. This is indicated by the difference in the transmission time of the wave and the reading results. The readings on concrete with a crack depth of 4 cm have the largest error value relative to the actual value, which is 8.5% at a transducer distance of 5 cm and the smallest is 0.5% at a transducer distance of 15 cm. Concrete with a crack depth of 8 cm has a reading with the largest error value relative to the actual value, which is 46.5% at a transducer distance of 5 cm and the smallest is 4% at a transducer distance of 15 cm. And concrete with a crack depth of 12 cm has a reading with the largest error value relative to the actual value, which is 57.33% at a transducer distance of 5 cm and the smallest is 0.17% at a transducer distance of 15 cm. So it can be concluded that the smaller the distance between the transducers, the value produced in the reading is getting further away from the actual crack value. The results of the UPV test in this study also showed that the greater the distance between the transducers and the depth of the crack, the higher the transmission time of the resulting wave

Other obstract

-

Item Type: Thesis (Sarjana)
Identification Number: 052107
Uncontrolled Keywords: Retak, UPV (Ultrasonic Pulse Velocity), Transduser
Subjects: 600 Technology (Applied sciences) > 624 Civil engineering
Divisions: Fakultas Teknik > Teknik Sipil
Depositing User: Samsul Arifin
Date Deposited: 28 Oct 2021 07:09
Last Modified: 24 Feb 2022 04:53
URI: http://repository.ub.ac.id/id/eprint/186178
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
NAUFAL RAFIF RIZQULLAH 175060101111015 -.pdf
Restricted to Registered users only until 31 December 2023.

Download (9MB)

Actions (login required)

View Item View Item