Oktova., Rona Asri (2021) Penilaian Green Building Kriteria Appropriate Site Development dan Building Environment Management Pada Gedung Fakultas Teknologi Pertanian, Universitas Brawijaya. Sarjana thesis, Universitas Brawijaya.
Abstract
Penyebab pemanasan global di Indonesia yaitu semakin menurunnya daya dukung lingkungan akibat pencemaran dan eksploitasi sumber daya alam yang berlebih. Salah satunya yaitu pembangunan yang tidak mengindahkan kondisi lingkungan. Penurunan kondisi lingkungan ini menjadikan faktor pendorong munculnya gerakan green building. Green Building dapat menjadi solusi untuk menahan laju pemanasan global melalui sektor pembangunan yang bermanfaat bagi lingkungan, ekonomi dan sosial. Indonesia sudah memiliki standar penilaian atau sistem rating Green Building yang dibuat oleh lembaga GBC Indonesia yang dinamakan Greenship. Berdasarkan GBCI dalam penerapan konsep green building terdapat 6 kriteria yang harus diterapkan seperti Appropriate Site Development, Building Environment Management dan 4 kriteria lainnya. Tujuan dari penelitian ini adalah mengetahui rating dari penerapan Green Building, mendapatkan ketidaksesuaian gedung dalam penerapan green building dan memberikan rekomendasi untuk perbaikan gedung dalam penerapan Green Building pada 2 kriteria berdasarkan Greenship Existing Building Version 1.1. Metode penelitian yang digunakan yaitu deskriptif kuantitatif dengan metode pengambilan data yaitu observasi, pengukuran dan wawancara secara langsung. Penelitian dilaksanakan di FTP UB Gedung C, D, dan F selama 4 bulan yaitu pada Bulan Maret sampai Juni 2021. Hasil dari observasi pengukuran dan wawancara secara langsung, didapat penilaian green building FTP UB menunjukkan bahwa FTP UB belum memenuhi prasyarat penilaian greenship. Selain itu, berdasarkan hasil penilaian FTP UB hanya mendapat nilai 3 poin dari kriteria Appropriate Site Development dan Building Environment Management. Dalam penerapan green building FTP UB belum terdapat kategori yang sudah menerapkan setiap kategori secara penuh. Namun, terdapat beberapa kategori yang tolak ukurnya sudah diterapkan atau sesuai dengan penilaian, namun hanya terlaksana sebanyak 3 dari total 29 tolak ukur. Rekomendasi yang dapat dilakukan FTP yaitu menambah fasilitas akses pejalan kaki, sumur injeksi, parkir sepeda, membuat kebijakan pengurangan pemakaian kendaraan pribadi, membuat SPO, membuat program training untuk karyawan, dan melengkapi dokumen prasyarat serta dokumen penilaian lainnya
English Abstract
The cause of global warming in Indonesia is the decreasing environmental carrying capacity due to pollution and excessive exploitation of natural resources. One of them is development that does not heed environmental conditions. The decline in environmental conditions is a driving factor for the emergence of the green building movement. Green Building can be a solution to curb global warming through development sectors that are beneficial to the environment, economy and social. Indonesia already has an assessment standard or a rating system GBC Indonesia called Greenship. Based on the GBCI in the application of the green building concept there are 6 criteria that must be applied, such as Appropriate Site Development, Building Environment Management and 4 other criteria. The purpose of this study was to determine the rating of the application of Green Building, to find the incompatibility of buildings in the application of green buildings and to provide recommendations for building improvements in the application of Green Building on 2 criteria based on Greenship Existing Building Version 1.1. The research method used is descriptive quantitative with data collection methods namely observation, measurement and direct interviews. The research was carried out at the Faculty of Agricultural Technology, Buildings C, D, and F of Brawijaya University, Malang with a research time of 3 months, from March to June 2021. The results of direct measurement observations and interviews, the assessment of green building FTP UB shows that FTP UB have not met the prerequisites for the assessment greenship. In addition, based on the results of FTP UB's assessment, it only gets 3 points from the criteria of Appropriate Site Development and Building Environment Management. In the application of green building FTP UB, there is no category that has fully implemented each category. However, there are several categories in which benchmarks have been applied or are in accordance with the assessment, but only 3 out of a total of 29 benchmarks have been implemented. Recommendations that can be made by FTP are adding pedestrian access facilities, injection wells, bicycle parking, making policies to reduce the use of private vehicles, making SOPs, making training programs for employees, and completing prerequisite documents and other assessment documents
Other obstract
-
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | 052110 |
Subjects: | 600 Technology (Applied sciences) > 630 Agriculture and related technologies > 630.92 Farmers |
Divisions: | Fakultas Teknologi Pertanian > Teknologi Industri Pertanian |
Depositing User: | Samsul Arifin |
Date Deposited: | 20 Oct 2021 03:24 |
Last Modified: | 03 Oct 2024 06:48 |
URI: | http://repository.ub.ac.id/id/eprint/184258 |
Text
RONA ASRI OKTOVA.pdf Download (6MB) |
Actions (login required)
View Item |