Pengaruh Komposisi Membran Poli Vinil Alkohol(PVA) Terhadap Kepekaan Sensor Potensiometri Klorpirifos

Tamaya, Yessi (2019) Pengaruh Komposisi Membran Poli Vinil Alkohol(PVA) Terhadap Kepekaan Sensor Potensiometri Klorpirifos. Sarjana thesis, Universitas Brawijaya.

Abstract

Penelitian ini bertujuan untuk mempelajari pengaruh konsentrasi klorpirifos dalam membranpoli vinil alkohol (PVA), konsentrasi membran-PVA, dan pengaruh partikel Fe3O4 terhadap kepekaan sensor. Pada pengaruh konsentrasi klorpirifos, membran- PVA terbuat dari 90% PVA,4% glutaraldehid , 5% asam sitrat, dan klorpirifos sebanyak 0%; 0,05%; 0,1%; 0,15%; dan 0,2% (b/b). Sedangkan, pada pengaruh konsentrasi membran dan partikel Fe3O4, membran-PVA terbuat dari 91,7% PVA, 8,2% glutaraldehid, dan 0,1% klorpirifos. Campuran dikeringkan pada suhu 50oC selama 8 jam. Membran-PVA dicuci sebanyak dua kali dengan etanol , kemudian dikeringkan pada suhu 50oC selama 30 menit. Membran- PVA ditimbang sebanyak 0,05 g; 0,075 g; 0,1 g; 0,15 g; dan 0,2 g dan dilarutkan dalam 4 mL air panas 50oC, kemudian ditambahkan asam sitrat 10% sampai volumenya mencapai 5 mL. Pengaruh Fe3O40,5% dipelajari pada konsentrasi membran-PVA 1%. Pengujian sensor menggunakan larutan klorpirifos10-13-10-6 M pada buffer fosfat pH 6. Berdasarkan hasil penelitian, konsentrasi klorpirifos dan konsentrasi membran-PVA mempengaruhi kepekaan sensor. Kepekaan sensor tertinggi diperoleh ketika konsentrai klorprifos 0,1% dan konsentrasi membran-PVA 1% dengan bilangan Nernst 13,8 mV/dekade dan 10,5 mV/dekade. Kepekaan sensor menurun dengan adanya partikel Fe3O4 0,5% dalam membran-PVA.

English Abstract

This research aims to study the effect of chlorpyrifos concentration in poly vinyl alcohol(PVA) membranes, membrane- PVA concentration, and the effect of Fe3O4 particles on sensor sensitivity. At the influence of chlorpyrifos concentration, membranes-PVA are made of 90% PVA, 4% glutaraldehyde, 5% citric acid, and 0%; 0.05%; 0.1%; 0.15%; and 0.2% (w/w)chlorpyrifos. Whereas, on the influence of membrane concentration and particles of Fe3O4, PVA-membrane was made of 91.7% PVA, 8.2% glutaraldehyde, and 0.1% chlorpyrifos. The mixture was dried at 50oC for 8 hours. Membrane-PVA is washed twice with ethanol, then dried at 50oC for 30 minutes. PVA membrane weighed 0.05 g; 0.075 g; 0.1 g; 0.15 g; and 0.2 g and dissolved in 4 mL of 50oC hot water, then 10% citric acid is added until the volume reaches 5 mL. The effect of Fe3O4 0.5 %was studied at 1% PVA-membrane concentration. Testing the sensor using chlorpyrifos 10-13-10-6M solution in pH 6 phosphate buffer. Based on the results of the study, chlorpyrifos concentration and membrane- PVA concentration affected sensor sensitivity.The highest sensitivity of the sensor was obtained when chlorpyrifos concentration 0.1% and membrane-PVA concentration 1% with Nernst number 13.8 mV / decade and 10.5 mV / decade. Sensitivity of the sensor decreased with the presence of 0.5% Fe3O4 particles in the PVA-membrane.

Other obstract

-

Item Type: Thesis (Sarjana)
Identification Number: SKR/MIPA/2019/23/051910725
Uncontrolled Keywords: Klorpirifos, sensor kimia, potensiometri, Fe3O4, poli vinil alkohol (PVA). Chlorpyrifos, chemical sensor, potentiometric, Fe3O4, poly vinyl alcohol (PVA)
Subjects: 500 Natural sciences and mathematics > 547 Organic chemistry > 547.03 Oxy and hydroxy compounds > 547.031 Alcohols
Divisions: Fakultas Matematika dan Ilmu Pengetahuan Alam > Kimia
Depositing User: Budi Wahyono Wahyono
Date Deposited: 19 Jul 2020 08:25
Last Modified: 28 Mar 2022 06:43
URI: http://repository.ub.ac.id/id/eprint/176730
[thumbnail of Yessi Tamaya.pdf]
Preview
Text
Yessi Tamaya.pdf

Download (2MB) | Preview

Actions (login required)

View Item View Item