Abstract

Waduk Selorejo dan Waduk Wlingi merupakan waduk besar yang berada di DAS Brantas, memiliki beberapa fungsi salah satunya sebagai tempat penyedia air. Air yang ditampung di Waduk Selorejo dan Wlingi berasal dari aliran sungai yang mengalir ke waduk tersebut. Air yang masuk ke waduk tidak hanya mengandung senyawa air murni tetapi juga mengandung bahan-bahan lain baik organik maupun anorganik. Bahan-bahan tersebut berasal dari buangan limbah akibat adanya aktivitas manusia di sekitar aliran sungai. Oleh karena itu, dimungkinkan pada kedua waduk memiliki kualitas air yang berbeda. Sehingga perlu dilakukan adanya pengukuran kualitas air berdasarkan sifat kimia sehingga pemanfaatan air waduk dapat dilakukan secara tepat. Penelitian ini bertujuan untuk mengetahui kualitas air dan mengetahui pemanfaatan air waduk sesuai dengan kualitas air pada Waduk Selorejo dan Waduk Wlingi. Kegiatan penelitian dilaksanakan mulai bulan Januari sampai Maret 2019 di Waduk Selorejo dan Waduk Wlingi. Pengambilan sampel kualitas air di Waduk Selorejo dilakukan pada 3 titik yaitu bagian hulu (pada kedalaman 0,3 m dan 3 m), tengah (pada kedalaman 0,3 m; 5 m; dan 10 m), dan hilir (pada kedalaman 0,3 m; 5 m; dan 10 m) yang setiap titiknya dilakukan 3 kali ulangan. Pengambilan sampel kualitas air di Waduk Wlingi dilakukan pada satu titik (pada kedalaman 14-17 m) dengan 3 kali ulangan dengan menggunakan alat Vertical Water Sampler. Metode penelitian yang dilakukan yaitu dengan melakukan pengamatan langsung di lapangan dengan melihat beberapa parameter sifat kimia yaitu pH dan DO. Parameter BOD yang dianalisis di Laboratorium Fisika Tanah, Fakultas Pertanian, Universitas Brawijaya. Sedangkan NO3¯ yang dianalisis di Laboratorium Kimia, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Brawijaya. Berdasarkan hasil pengukuran parameter kimia, Waduk Selorejo masuk dalam kelas kualitas air kelas II dan Waduk Wlingi masuk dalam kelas kualitas air kelas III.ii Air Waduk Selorejo sebagian besar dimanfaatkan untuk mengairi lahan pertanian milik warga sekitar waduk, penggerak turbin pada PLTA Selorejo, budidaya ikan air tawar, peternakan, serta sarana atau prasarana rekreasi air dan sudah sesuai dengan peruntukannya berdasarkan kelas kualitas air menurut PP No 82 Tahun 2001. Air di Waduk Wlingi dipergunakan sebagai penggerak turbin pada PLTA Wlingi serta peternakan sehingga belum sesuai dengan peruntukannya berdasarkan kelas kualitas air menurut PP No 82 Tahun 2001.

English Abstract

Selorejo Reservoir and Wlingi Reservoir are large reservoir that located in the Brantas watershed, which have many functions, for example as a water supply. The water that collected in Selorejo Reservoir and Wlingi Reservoir sourced from the river flowing into reservoir. The water that enter the reservoir not only contains pure water but also contais other ingredients (organic and anorganic). These materials come from waste human activity around the river flow. Therefore, Selorejo Reservoir and Wlingi Reservoir have different water quality. So it is necessary to do the analysis of water quality in Selorejo Reservoir and Wlingi Reservoir to determine water quality based on chemical characteristic so water can be used correctly. The objective of this research were to determine water quality and discover the usage of water in Selorejo Reservoir and Wlingi Reservoir. The research was held from January to Maret 2019 in Selorejo Reservoir and Wlingi Reservoir. Water sampling in Selorejo Reservoir was taken at 3 points, i.e upstream (0,3m and 3m depth), middle segment (0,3m , 5m and 10m depth), and in downstream (0,3m , 5m and 10m depth) with 3 replications. Water sampling in Wlingi Reservoir was taken at 1 point (14-17 m depth) which did in 3 times that used Vertical Water Sampler. The research method was direct observations in field by measure several chemical parameters like pH and DO. BOD was analyzed at Soil Physic Laboratory, Faculty of Agriculture, Brawijaya University and parameter NO3¯ that was analyzed at Chemistry Laboratory, Faculty of Mathematic and Science, Brawijaya University. Based on the results of measurements of chemical parameters, Selorejo Reservoir is classified in class II and Wlingi Reservoir is classified in class III. Water in Selorejo Reservoir was used to irrigate the agricultural land in the downstream area of Selorejo Reservoir hydroelectric power generator, inland fisheries, farm, water recreation facilities or infrastructure and the water in Selorejo Reservoir was usediv correctly according to PP. No 82 Tahun 2001. Water in Wlingi Reservoir was used as hydroelectric power generator and farm and water in Wlingi was not used correctly according to PP. No 82 Tahun 2001

Other obstract

-

Item Type: Thesis (Sarjana)
Identification Number: SKR/FP/2019/249/051906992
Subjects: 600 Technology (Applied sciences) > 631 Specific techniques; apparatus, equipment materials > 631.7 Water conservation
Divisions: Fakultas Pertanian > Ilmu Tanah
Depositing User: Nur Cholis
Date Deposited: 28 Jul 2020 05:58
Last Modified: 22 Oct 2021 03:04
URI: http://repository.ub.ac.id/id/eprint/172974
[thumbnail of OLGA LINGGAR PUTRI (2).pdf]
Preview
Text
OLGA LINGGAR PUTRI (2).pdf

Download (2MB) | Preview

Actions (login required)

View Item View Item