Nugroho, Waluyo Tirto (2018) Pengaruh Jumlah Fe3O4 pada Pembuatan Sensor Potensiometri untuk Parasetamol Menggunakan Membran Selektif MIP (Molecularly Imprinted Polymer) pada Permukaan SPCE (Screen Printed Carbon Electrode). Sarjana thesis, Universitas Brawijaya.
Abstract
Penelitian ini bertujuan untuk mempelajari pengaruh jumlah Fe3O4 dalam membran selektif MIP terhadap kinerja sensor potensiometri parasetamol. Tiga sensor diuji, satu sensor tanpa Fe3O4 dan dua sensor menggunakan Fe3O4 dengan konsentrasi 0,5% dan 2% w/w. Sensor dengan kinerja terbaik diuji terhadap perubahan pH yaitu 8,9,10, dan 11. Membran selektif MIP dibuat menggunakan PVA sebagai monomer, gluteraldehid sebagai pereaksi pengikat silang, dan asam sitrat sebagai pembuat suasana asam yang berguna agar terjadi reaksi ikatan silang antara PVA dengan gluteraldehid. Fe3O4 dibuat dengan metode kopresipitasi, reaksi antara campuran larutan FeSO4 ,FeCl3, dan (NH4)2SO4 dengan larutan NaOH panas. Endapan Fe3O4 disaring dan dicuci dengan akuades hingga bebas ion. Tiga larutan membran dibuat, lalu dilapiskan sebanyak 2,5 μL pada elektroda indikator (SPCE) dan dipanaskan dengan suhu 50oC selama 10 menit. Pelapisan membran dilakukan sebanyak dua kali setelah dilakukan pemanasan yang pertama. Hasil penelitian menunjukkan bahwa konsentrasi Fe3O4 dalam MIP berpengaruh terhadap sensitivitas sensor. Sensitivitas sensor terbaik dihasilkan pada konsentrasi Fe3O4 sebesar 0,5% pada membran selektif MIP. Sensor ini bekerja pada kisaran konsentrasi 1x10-5 sampai 1x10-9 M, yang memberikan nilai Nernst sebesar 42,6 mV/dekade pada pH 11 dengan waktu respon dari sensor sebesar 170 detik.
English Abstract
The aims of the research were to study the effect of amount Fe3O4 in selective MIP membrane to the performance of paracetamol potensiometric sensors. Three sensors tested, one sensor without Fe3O4 and the other using Fe3O4 with concentration 0,5% and 2% w/w. Sensors which the best performance tested to the change of pH such as 8,9,10, and 11. Selective MIP membrane made using PVA as monomer, gluteraldehide as crosslinking agent, and citric acid as acid circumtances maker which useful to happen crosslinking between PVA with gluteraldehide. Fe3O4 made with coprecipitation method, reaction between mixture of FeSO4 solution, FeCl3, and (NH4)2SO4 with hot NaOH solution. Fe3O4 precipitation was filtered and washed with aquades until free from ion. Three membrane solution was made, then coated as much 2,5 μL on the indikator electrode (SPCE) and was heated in the oven in 500C for 10 minutes. Coating membrane was did as much twice after the first heated in the oven. Research result that Fe3O4 concentration in MIP took effect to the sensors sensitivity. The best performance sensors obtained using 0,5%w/w Fe3O4 on the selective MIP membrane. This sensors work on the range of concentration 1x10-5 until 1x10-9 M which give Nernst number 42,6 mV/decade in pH 11 with response time from sensors 170 seconds.
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | SKR/MIPA/2018/440/051900369 |
Uncontrolled Keywords: | Fe3O4, membran selektif MIP, faktor Nernst, pH, kisaran konsentrasi Fe3O4, selective MIP membrane, Nernst factor, pH, range of concentration |
Subjects: | 500 Natural sciences and mathematics > 542 Techniques, procedures, apparatus, equipment, materials > 542.8 Auxiliary techniques procedures, electrical and electronic equipment |
Divisions: | Fakultas Matematika dan Ilmu Pengetahuan Alam > Kimia |
Depositing User: | Budi Wahyono Wahyono |
Date Deposited: | 24 Aug 2020 06:45 |
Last Modified: | 18 Oct 2021 04:44 |
URI: | http://repository.ub.ac.id/id/eprint/168736 |
Preview |
Text
Waluyo Tirto Nugroho (2).pdf Download (2MB) | Preview |
Actions (login required)
View Item |