Furqon, Mochammad Sahlul (2018) Pembuatan dan Karakterisasi PIM(Polymer Inclusion Membrane) Aliquat 336-Cl/DOP sebagai Passive Sampler untuk Deteksi SCN. Sarjana thesis, Universitas Brawijaya.
Abstract
Tiosianat adalah produk samping dari limbah domestik dan tambang emas. Tujuan dari penelitian ini adalah menentukan pengaruh kecepatan pengadukan fasa ruah dan konsentrasi ekstraktan dalam PIM terhadap kinerja passive sampler untuk deteksi ion tiosianat di lingkungan perairan. PIM dibuat dengan mencampurkan PVC sebagai polimer dasar, Aliquat 336-Cl sebagai ekstraktan, dan DOP sebagai pemlastis dalam pelarut THF (tetrahidrofuran). Konsentrasi ekstraktan divariasi 10%,15%, and 20% w/w. Passive sampler dibuat dari sebuah botol 5 mL yang diisi dengan larutan NaCl 1 M sebagai inner solution dan ditutup dengan PIM. Passive sampler kemudian direndam dalam fasa ruah berisi larutan tiosianat 100 mg/L dengan bagian PIM mengarah pada larutan ruah. Fasa ruah diaduk dengan kecepatan bervariasi 600, 800, 1000 rpm selama 180 menit. Setiap 30 menit, passive sampler diambil. Konsentrasi ion tiosianat dalam larutan inner di passive sampler kemudian ditentukan dengan metode spektrofotometri sinar tampak pada 460 nm berdasarkan pembentukan sanya komplek besi (III) tiosianat. Selanjutnya, laju sampling (Rs) dan and konsentrasi rata-rata per waktu (CTWA) dihitung berdasarkan waktu kinetik. Hasil penelitian menunjukkan bahwa passive sampler menghasilkan Rs dan CTWA optimal dengan kecepatan pengadukan fasa ruah 100 rpm. Passive sampler dengan PIM yang mengandung Aliquat 336-Cl 20% w/w mempunyai kinerja yang bagus dengan nilai Rs dan CTWA masing-masing adalah 1 x 10-5 L/menit dan 93,58 mg/L. Passive sampler tersebut menunjukkan akurasi yang bagus untuk mendeteksi ion tiosianat sebesar 95,62%.
English Abstract
Thiocyanate is side product of cyanide from domestic and gold mining wastes. The aims of this research were to determine the effect of stirring speed and extractant concentration of PIM to the performance of passive sampler for thiocyanate detection in water environment. PIM was prepared by mixing PVC as base polymer, Aliquat 336-Cl as extractant, and DOP as plasticizer in THF (tetrahydrofuran) solvent. Extractant concentrations were varied 10%,15%, and 20% w/w. Passive sampler was developed from a 5 mL bottle filled by NaCl 1 M as the inner solution and capped by PIM. Passive samplers were then deployed into a bulk solution of thiocyanate solution of 100 mg/L with the PIM was faced down into the bulk solution. The bulk solution was stirred at 600, 800, 1000 rpm for 180 minutes. In every 30 minute, a passive sampler was taken out. The thiocyanate concentration in the inner solution of passive sampler was then determined using visible spectrophotometric method at 460 nm based on the formation of iron (III) thiocyanate complex compound. Furthermore, the sampling rate (Rs) and the time average concentration (CTWA) were calculated based on the kinetic time. Results showed that a passive sampler had a good performance at stirring speed of 800 rpm. Passive sampler with PIM consisted of Aliquat 336-Cl 20% w/w had good performance with Rs and CTWA values were 1 x 10-5 L/minute and 93.58 mg/L, respectively. This passive sampler showed a good accuracy in thiocyanate ion detection by 95.52%.
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | SKR/MIPA/2018/490/051900550 |
Uncontrolled Keywords: | Tiosianat, PIM, Passive Sampler, CTWA, dan Laju sampling./ Thiocyanate, PIM, Passive Sampler, CTWA, sampling rate. |
Subjects: | 300 Social sciences > 363 Other social problems and services > 363.7 Environmental problems > 363.72 Sanitation > 363.728 Wastes > 363.728 8 Specific kinds of wastes |
Divisions: | Fakultas Matematika dan Ilmu Pengetahuan Alam > Kimia |
Depositing User: | Endang Susworini |
Date Deposited: | 08 Jul 2020 06:18 |
Last Modified: | 18 Jan 2022 06:31 |
URI: | http://repository.ub.ac.id/id/eprint/168582 |
Preview |
Text
Mochammad Sahlul Furqon (2).pdf Download (1MB) | Preview |
Actions (login required)
![]() |
View Item |