Optimasi Volume Sample Loop dan Konsentrasi Floroglusinol Serta Uji Validitas Menggunakan Metode Flow Injection Analysis (FIA)-Spektrofotometri untuk Penentuan Hidrokuinon pada Kosmetik

Khauf, Grahita Triikhtiardi Aulia (2018) Optimasi Volume Sample Loop dan Konsentrasi Floroglusinol Serta Uji Validitas Menggunakan Metode Flow Injection Analysis (FIA)-Spektrofotometri untuk Penentuan Hidrokuinon pada Kosmetik. Sarjana thesis, Universitas Brawijaya.

Abstract

Hidrokuinon merupakan salah satu bahan berbahaya yang sering digunakan untuk memutihkan wajah, obat untuk kulit kusam dan flek melalui mekanisme penghambatan enzim tirosin dalam pembentukan melanin. Hidrokuinon banyak digunakan dalam kosmetik. Pengembangan metode yang memiliki efisiensi waktu, sampel, reagen, dan akurat diperlukan untuk memonitoring kosmetik yang mengandung hidrokuinon. Pada penelitian ini, telah dikembangkan penentuan hidrokuinon dengan metode Flow Injection Analysis (FIA)-spektrofotometri berdasarkan pembentukan kompleks hidrokuinon-floroglusinolat. Ion OH- dari NaOH akan menyerang hidrogen pada gugus hidroksi dari floroglusinol sehingga akan membentuk ion floroglusinolat. Kemudian ion floroglusinolat bereaksi dengan hidrokuinon dan membentuk kompleks hidrokuinonfloroglusinol berwarna merah pada panjang gelombang 493 nm. Parameter yang dioptimasi pada penelitian ini meliputi optimasi volume sample loop, penentuan konsentrasi floroglusinol optimum dan uji validasi dengan metode adisi standar. Volume sample loop optimum pada 100 μL, konsentrasi floroglusinol yang diperlukan yaitu 150 ppm. Hasil penelitian ini menunjukkan bahwa kisaran konsentrasi hidrokuinon yang dapat terdeteksi adalah 1-10 ppm. Uji validasi diaplikasikan pada 2 sampel kosmetik menunjukkan % recovery pada sampel A 55,5 % dan sampel B 59,0 %.

English Abstract

Hydroquinone is one of the most dangerous ingredient in cosmetics that is often used to whiten skin, to cure the dull skin and spots through the inhibition mechanism tyrosine enzyme in the formation of melanin. An efficient method is required to monitor the presence of hydroquinone in cosmetics to avoid the hazard effect to human. A method for hydroquinone determination has been developed using Flow Injection Analysis (FIA)-spectrophotometry based on the formation of hydroquinone-phloroglucinol complex. The OH- ion of NaOH will attack hydrogen of hydroxy group of phloroglucinol to form phloroglucinolate ion. Then, the floroglusinolate ion reacts with hydroquinone and forms a red hydroquinone-floroglucinolate complex detected at a wavelength of 493 nm. The sample loop and phlorogucinol were optimized to achieve sensitivity of the method and the method was validated using standard addition method. Optimum conditions were obtained under the sample loop of 100 μL, and phlorogucinol concentration of 150 ppm. The result of this study indicated that the linear concentrations for measuring hydroquinone was in the range from 1-10 ppm. Validation test was applied to two type of cosmetic samples resulting acceptable recoveries with respective values of 55,5 % for cosmetic A and 59,0 % for cosmetic B

Other obstract

-

Item Type: Thesis (Sarjana)
Identification Number: SKR/MIPA/2018/286/051807046
Uncontrolled Keywords: Hidrokuinon, FIA, kompleks hidrokuinonfloroglusinol, sample loop, validitas, Hydroquinone, FIA, phlorogucinol, sample loop, validity
Subjects: 500 Natural sciences and mathematics > 547 Organic chemistry > 547.6 Aromatic compounds > 547.63 Oxy and hydroxy compounds > 547.633 Polyhydroxy aromatics
Divisions: Fakultas Matematika dan Ilmu Pengetahuan Alam > Kimia
Depositing User: Nur Cholis
Date Deposited: 24 Jun 2020 06:48
Last Modified: 22 Oct 2021 08:32
URI: http://repository.ub.ac.id/id/eprint/168454
[thumbnail of GRAHITA TRIIKHTIARDI AULIA KHAUF.pdf]
Preview
Text
GRAHITA TRIIKHTIARDI AULIA KHAUF.pdf

Download (2MB) | Preview

Actions (login required)

View Item View Item