Kusuma, Ragil Danang (2018) Studi Sistem Signal Generator Arbitrary Waveform Dengan Berbasis Direct Digital Synthesizer (Dds) Ad9910 Evaluation Board. Sarjana thesis, Universitas Brawijaya.
Abstract
Dalam teknologi digital saat ini, terdapat signal generator yang menggunakan teknologi Direct Digital Synthesizer (DDS). DDS ini menerapkan metode digital untuk membuat sinyal analog menggunakan Digital to Analog Converter (DAC). Pada DDS AD9910 terdapat fitur RAM (1024 deep memory address) yang berfungsi sebagai penyimpanan data sampling digital untuk menghasilkan arbitrary waveform. Studi signal generator AD9910 Evaluation Board bertujuan untuk memahami karakteristik alat tersebut untuk diterapkan sebagai alat simulasi pembangkit sinyal arbitrary waveform ataupun sebagai sinyal uji untuk suatu sistem atau sensor. Pemilihan clock eksternal pada sistem AD9910 Evaluation Board adalah 100 MHz dengan PLL 10x dan VCO range 656 - 832 MHz. Pemilihan itu dipilih karena memiliki stabilitas yang cukup baik dan mampu menghasilkan sistem clock 1000 MHz dengan periode sampling sebesar 4 nS. RAM Modulation Mode menghasilkan output tegangan maksimum setengah dari tegangan clock referensi. Sinyal arbitrary waveform yang dihasilkan dalam penelitian ini adalah sinyal sinus, kotak, segitiga, gabungan dan ECG. Sinyal yang dihasilkan memiliki bentuk yang baik dibandingkan dengan bentuk yang diberikan dalam bentuk digital. Namun, ada sedikit perbedaan karena terbatasnya kemampuan DAC sistem AD9910 Evaluation Board. Sinyal EKG yang dihasilkan menunjukkan pola yang baik dibandingkan dengan bentuk digital yang diberikan. Jumlah RAM internal adalah salah satu faktor terbatas untuk menghasilkan sinyal arbitrary waveform yang lebih kompleks.
English Abstract
In today's digital technology, there is a signal generator that uses Direct Digital Synthesizer (DDS) technology. This DDS applies a digital method for making analog signals using Digital to Analog Converter (DAC). On the AD9910 DDS there is a RAM feature (1024 deep memory address) that serves as a storage of digital data sampling to produce arbitrary waveforms. The AD9910 Evaluation Board signal generator study aims to understand the characteristics of the tool to be applied as a simulation tool for an arbitrary waveform signal generator or as a test signal for a system or sensor. The selection of an external clock on the AD9910 Evaluation Board system is 100 MHz with PLL 10x and VCO range 656 - 832 MHz. That selection was chosen because it has a good enough stability and able to generate a clock system of 1000 MHz with a sampling period of 4 nS. The RAM Modulation Mode produces a maximum voltage output of half the reference clock voltage. The generated arbitrary waveform signals in this study was sine, square, triangle, combination and ECG signals. The generated signals have a good shape compared to the given shape in the digital form. However, there was a slight differences due to limited AD9910 Evaluation Board system DAC output capabilities. The generated ECG signal showed a well pattern compare to the given digital form. The amount of the internal RAM was one of the limited factor to generate a more complex arbitrary waveform signal
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | SKR/MIPA/2018/539/051901790 |
Uncontrolled Keywords: | signal generator, DDS, RAM, arbitrary waveform. |
Subjects: | 600 Technology (Applied sciences) > 621 Applied physics > 621.3 Electrical, magnetic, optical, communications, computer engineering; electronics, lighting > 621.38 Electronics, communications engineering > 621.381 Electronics > 621.381 5 Components and circuits > 621.381 53 Printed circuits and circuits for specific functions > 621.381 535 Amplifiers and feedback circuits > 621.381 548 Testing and measuring components |
Divisions: | Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika |
Depositing User: | Budi Wahyono Wahyono |
Date Deposited: | 19 Jun 2020 02:15 |
Last Modified: | 18 Oct 2021 07:08 |
URI: | http://repository.ub.ac.id/id/eprint/168239 |
Preview |
Text
Ragil Danang Kusuma (2).pdf Download (3MB) | Preview |
Actions (login required)
View Item |