Efektivitas Pengolahan Limbah Cair Laundry Menggunakan Metode Koagulasi Dengan Variasi Dosis Koagulan Pac Dan Aluminium Sulfat (Studi Kasus : Padma Resort, Puhu, Payangan, Gianyar Bali)

Pertiwi, Dewa Ayu Made Dina (2018) Efektivitas Pengolahan Limbah Cair Laundry Menggunakan Metode Koagulasi Dengan Variasi Dosis Koagulan Pac Dan Aluminium Sulfat (Studi Kasus : Padma Resort, Puhu, Payangan, Gianyar Bali). Sarjana thesis, Universitas Brawijaya.

Abstract

Pulau Bali merupakan salah satu destinasi pariwisata di Indonesia yang paling diminati oleh wisatawan asing maupun domestik. Berdasarkan data Badan Pusat Statistik Provinsi Bali jumlah kunjungan wisata pada tahun 2016 tercatat sebesar 4.927.937 jiwa. Sektor jasa pelayanan pendukung pariwisata yang kini telah banyak meningkat yaitu usaha laundry. Dampak negatif dari peningkatan usaha laundry yaitu pencemaran tanah, air dan kesehatan karena limbah cair laundry mengandung toxic. Dalam mengatasi permasalahan limbah cair laundry maka dilakukan penelitian dengan metode koagulasi flokulasi dengan menggunakan PAC dan tawas. Tujuan dari penelitian ini yaitu untuk mengetahui efektivitas dari koagulan PAC dan tawas yang sesuai dengan kombinasi dosis berdasarkan parameter uji. Parameter uji terdiri dari COD, TSS, kekeruhan dan pH. Kecepatan pengadukan cepat 120 rpm dan pengadukan lambat 60 rpm. Pengujian dilakukan dengan menggunakan jar test. Metode analisis data yang digunakan yaitu RAK (Rancangan Acak Kelompok). Kualitas sampel awal limbah cair laundry yaitu parameter COD 171,32 mg/L, TSS 62,35 mg/L, MBAS 7,12 mg/L, kekeruhan 47,57 NTU, pH 8.09, suhu 26 0C. Penurunan nilai parameter dari pengolahan limbah cair laundry dengan metode koagulasi flokulasi yang paling efektif yaitu kombinasi dosis A0B3 (Tawas 0 ppm, PAC 60 ppm). Penurunan nilai pada parameter COD yaitu 61,62 mg/L dengan persentase penurunan sebesar 64,03 %, TSS sebesar 31,06 mg/L dengan persentase penurunan sebesar 50,17 %, turbidity sebesar 33,82 NTU dengan persentase penurunannya 28,89%, MBAS sebesar 5,13 mg/L dengan persentase penurunannya 28,06 %, dan pH sebesar 7,63.

English Abstract

Bali Island is one of the most popular tourist destinations in Indonesia. Based on the data from Bali Central Bureau of Statistics the number of tourist visits in 2016 was recorded at 4.927.937 people. One of services sectors in supporting tourism that has now widely increased is laundry business. Negative impact of laundry business improvement is pollution of soil, water and health due to toxic-containing laundry liquid waste. In order to overcome laundry liquid waste problem, the research was done by using flocculation coagulation method by using PAC and alumminium sulfate. The purpose of this study was to determine the effectiveness of PAC coagulant and alumminium sulfate that corresponds to the combination of doses based on test parameters. The test parameters consisted of COD, TSS, turbidity and pH. Fast stirring speed was 120 rpm and slow stirring of 60 rpm. Testing was done by using jar test. Data analysis method used was GRD (Group Randomized Design). The quality of initial sample of laundry liquid waste was COD parameters of 171,32 mg/L, TSS 62,35 mg/L, MBAS 7,12 mg/L, turbidity of 47,57 NTU, pH 8,09, temperature of 26 0C. Decreasing parameter values of laundry liquid waste treatment with the most effective flocculation coagulation method is combination of dose A0B3 (alumminium sulfate of 0 ppm, PAC 60 ppm). The decrease of COD parameter was 61,62 mg/L with decrease percentage of 64,03%, TSS 31,06 mg/L with decrease percentage of 50,17%, turbidity equal to 33,82 NTU with decrease percentage of 28,89%, MBAS of 5,13 mg/L with decrease percentage of 28,06% and pH of 7,63.

Item Type: Thesis (Sarjana)
Identification Number: SKR/FTP/2018/246/051805709
Uncontrolled Keywords: Limbah Cair Laundry, Koagulasi Flokulasi, PAC, Tawas, Jar Test, COD, TSS, Kekeruhan, pH.,/ Laundry Liquid Waste, Flocculation Coagulation, PAC, Alumminium Sulfate, Jar Test, COD, TSS, Turbidity, pH.
Subjects: 600 Technology (Applied sciences) > 628 Sanitary engineering > 628.4 Waste technology, public toilets, street cleaning
Divisions: Fakultas Teknologi Pertanian > Keteknikan Pertanian