Abstract

Saat ini pengujian gas terlarut menggunakan alat kromatografi gas. Beberapa metode untuk analisis gas terlarut adalah Total Dissolved Combustible Gas (TDCG), rasio Dorneburg dan rasio International Electrotechnical (IEC). Semua metode tersebut untuk mendeteksi parameter gas yang mudah terbakar yaitu hydrogen, methane, carbon monoxida, ethylene, ethane dan acethylene . Penelitian ini bertujuan untuk mendesain dan membangun perangkat lunak dengan metode fuzzy logic untuk menentukan indikasi gangguan transformator sehingga akan didapatkan diagnosa dan kesimpulan yang benar untuk merekomendasikan terhadap kondisi transformator . Hasil uji kandungan gas pada Gardu Induk Blimbing, Polehan, Pakis, dan Turen dengan menggunakan program fuzzy logic menunjukkan hasil pada transformator dalam kondisi normal operasi, namun gas-gas tersebut perlu tetap dipantau. Hasil pengujian didapatkan metode fuzzy logic yang dibuat sudah dapat memenuhi atau sesuai dengan standar IEEE dan standar PT PLN P3B Jawa Timur Bali, karena hasil pengujian perbandingan menunjukkan kesesuaian hasil analisis untuk gangguan dan kondisi transformator.

English Abstract

Currently dissolved gas testing was using gas chromatography. common methods used for analysis of dissolved gases are Total Dissolved Gas (TDCG), Dorneburg ratio and ratio of International Electrotechnical (IEC). methods to detect combustible gas parameters are, hydrogen, methane, carbon monoxida, Ethylene, Ethane, and acethylene. This research aims are to design and develop software application considering fuzzy logic method to determine transformer fault indication such that recommended diagnoses and correct decision was of transformer condition achieved. results of research on Blimbing, Polehan, Pakis, and Turen Substations show that transformer in normal operation. While gases condition still under monitoring. Based on testing made, fuzzy logic method was able to meet and comply IEEE standard and PT PLN P3B East Java, Bali, standard. comparison results show that result analysis for fault and transformer condition was achieved.

Item Type: Thesis (Magister)
Identification Number: TES/665.7/ASH/a/041202499
Subjects: 600 Technology (Applied sciences) > 665 Technology of industrial oils, fats, waxes, gases > 665.7 Natural gas and manufactured gases
Divisions: S2/S3 > Magister Teknik Elektro, Fakultas Teknik
Depositing User: Endro Setyobudi
Date Deposited: 23 Oct 2012 11:53
Last Modified: 23 Oct 2012 11:53
URI: http://repository.ub.ac.id/id/eprint/160171
Full text not available from this repository.

Actions (login required)

View Item View Item