Elektroda Selektif Ion (ESI) Kromat Tipe Kawat Terlapis Bermembran Polimer Berbahan Aktif Kitosan

Kurniasih, Dedeh (2012) Elektroda Selektif Ion (ESI) Kromat Tipe Kawat Terlapis Bermembran Polimer Berbahan Aktif Kitosan. Magister thesis, Universitas Brawijaya.

Abstract

Senyawa Cr(VI) yang berada dalam perairan dapat disebabkan limbah buangan dari berbagai sektor industri seperti industri pelapisan logam dan cat. Cr(IV) bersifat sangat toksik dan dapat menyebabkan berbagai macam penyakit. Cr(IV) dalam perairan dapat ditentukan dengan beberapa cara diantaranya yaitu metoda spektrofotometri sinar tampak. Akan tetapi metoda ini memerlukan waktu yang relatif lama , instrumentasi yang mahal, tenaga ahli untuk mengoprasikannya dan tidak dapat menentukan kadar Cr(IV) dalam bentuk spesi kromat. Untuk itu diperlukan suatu metoda yang sederhana, murah namun memliki sensitivitas dan selektivitas yang tinggi untuk mendeteksi kadar Cr(VI) dalam bentuk spesi kromat. Penelitian ini bertujuan untuk membuat dan mengkarakterisasi ESI kromat tipe kawat terlapis agar dapat digunakan sebagai metoda alternatif dalam penentuan kromat dalam sampel air. Untuk mencapai tujuan tersebut, maka dilakukan optimasi komposisi membran yang terdiri dari campuran kitosan, aliquat 336-CrO­ 4 2- : PVC dan DOP sebagai plasticizer berdasarkan harga ∆d m . Selanjutnya ESI kromat diuji pengaruh lingkungan yang meliputi waktu perendaman, ion asing, pH, dan temperatur. Data hasil pengukuran metoda ESI divalidasi dengan cara membandingkannya dengan metoda spektrofotometri sinar tampak melalui uji korelasi regresi. Hasil penelitian menunjukkan bahwa komposisi penyusun membran yang optimum adalah 4 % kitosan : 0,5 % aliquat 336-CrO ­4 2- : 35 % PVC : 60,5 % DOP dengan faktor Nernst 29,77 mV/dek, rentang konsentrasi linier 10 -1 -10 -6 M, batas deteksi 0,226 ppm, waktu perendaman optimum adalah 20 menit, waktu respon 40 detik, dan usia pemakaian 49 hari. Urutan selektifitas ion kromat ion klorida ion fosfat ion asetat. ESI kromat tipe kawat terlapis dapat bekerja pada pH 5-9 dan temperatur 20-50 o C. Metoda ESI dan metoda standar tidak berbeda nyata sehingga metoda ESI kromat tipe kawat terlapis dapat digunakan sebagai metoda alternatif untuk penentuan kadar kromat dalam sampel air.

English Abstract

The existence of Cr(VI) compounds in waters can be caused of waste pollution from industrial activities such as industrial electroplating and paint. The Cr(VI) has toxic characteristic and is able to causing deseases. The levels of Cr(VI) can be determined by methods such as visible spectrophotometry. But this method need much time, require expensive instrument, laboratories expert and can not determine the levels of Cr(VI) in chromate form. Because of that, it is required a method that simple, cheap with good s e n si t ivity and selectivity which can determine Cr(VI) in chromate form . The aim of this study is to construct and characterize chromate ISE coated wire type as an alternative method to determine of chromate in waters sample. To reach that goal, the optimization of membrane composition was done by varying chitosan, aliquat 336-CrO ­4 2- , PVC, DOP based on ∆d m value. The chromate ISE obtained was examined to the influence of external factors, such as preconditions time, strange ions, pH, and temperature. The measurement data of chromate ISE was validated by comparing to those obtained from standard method of visible spectrophotometry . The result showed comparison the optimum composition of membrane was 4 % kitosan : 0,5 % aliquat 336-CrO­ 4 2- : 35 % PVC : 60,5 % DOP with Nernst factor of 29.77 mV/dec, linier concentration range of 10 -6 -10 -1 M, optimum precondition time of 20 minutes, respon time of 40 seconds, detection limit of 0,226 ppm, and life time of 49 days. The selectivity order was chromate ion chloride ion phosphate ion acetate ion. ISE chromate properly at pH of 5–9 and temperature 20-50 0 C. The result of measurement using ISE method and standard methods visible spectrophotometry is not significantly different, so the ISE chromate is able to be used as alternative method to determine that chromate on waters sample.

Item Type: Thesis (Magister)
Identification Number: TES/541.372 4/KUR/e/041204231
Subjects: 500 Natural sciences and mathematics > 541 Physical chemistry > 541.3 Miscellaneous topics in physical chemistry
Divisions: S2/S3 > Magister Matematika, Fakultas MIPA
Depositing User: Endro Setyobudi
Date Deposited: 22 Nov 2012 11:16
Last Modified: 22 Nov 2012 11:16
URI: http://repository.ub.ac.id/id/eprint/157525
Full text not available from this repository.

Actions (login required)

View Item View Item