Perencanaan Ulang Bangunan Kantor dengan Struktur Baja dan Sistem Balok Castellated

Pratama, Satya Agae and Ir. Mohammad Taufik Hidayat, MT and Dr. Ir. Retno Anggraini, ST., MT (2026) Perencanaan Ulang Bangunan Kantor dengan Struktur Baja dan Sistem Balok Castellated. Sarjana thesis, Universitas Brawijaya.

Abstract

Penelitian ini menjawab satu rumusan masalah, yaitu bagaimana merencanakan ulang struktur atas bangunan kantor menggunakan struktur baja dengan balok kastela (castellated beam) berdasarkan AISC Design Guide 31 dan ketentuan SNI 1729:2020 dengan metode Load and Resistance Factor Design (LRFD). Objek studi adalah gedung kantor empat lantai setinggi 16 m di Kota Malang, wilayah dengan risiko seismik tinggi, yang direncanakan menggunakan baja BJ-41 dan pelat beton f'c 25 MPa setebal 120 mm. Balok kastela dipilih karena ekspansi badan profil meningkatkan tinggi penampang dan kapasitas lentur tanpa menambah berat sendiri, sehingga gaya inersia gempa tidak bertambah, sekaligus menyediakan bukaan bagi jalur instalasi MEP. Prosedur perencanaan disusun berurutan: pembebanan mengikuti SNI 1727:2020, beban gempa dihitung dengan metode statik ekuivalen sesuai SNI 1726:2019, gaya dalam diperoleh dari pemodelan ETABS, geometri profil kastela mengacu pada AISC Design Guide 31, dan seluruh kontrol kekuatan serta kemampuan layan dihitung manual berdasarkan SNI 1729:2020 metode LRFD. Analisis gempa dengan kelas situs SE menghasilkan SDS = 0,69 G dan SD1 = 0,64 G, Kategori Desain Seismik D, sehingga digunakan Sistem Rangka Pemikul Momen Khusus (R = 8) dan diperoleh gaya geser dasar V = 996,71 kN dari berat seismik W = 11.604,90 kN. Balok induk bentang 12 m direncanakan sebagai balok kastela hasil ekspansi profil WF 500×200×10×16 dengan rasio ekspansi k = 1,5, menghasilkan tinggi penampang dg = 750 mm, tinggi tee 125 mm, tinggi bukaan ho = 500 mm, sudut potong 60° (dalam rentang 58°– 62°), serta 22 bukaan dengan panjang web-post 125,54 mm, tanpa menambah berat baja per meter panjang (tetap 89,6 kg/m). Aksi komposit dicapai dengan 23 penghubung geser stud ⌀19 mm dua baris per setengah bentang, disertai penutupan sepuluh bukaan di daerah geser tinggi. Elemen lainnya berupa balok induk bentang 6 m WF 400×200×8×13 (komposit parsial 86,8%), balok anak WF 300×150×6,5×9 (komposit penuh), dan kolom H 428×407×20×35 dengan rasio interaksi 0,507, sedangkan sambungan direncanakan menggunakan baut mutu tinggi A325 M20 dan las sudut elektroda E70 sesuai SNI 1729:2020 Bab J.xxii Seluruh kontrol kekuatan dan kemampuan layan menghasilkan rasio kapasitas kurang dari 1,0, dengan nilai tertinggi 0,883 pada kontrol geser vertikal balok kastela tahap pascakomposit sebagai kondisi batas yang menentukan. Dengan demikian, struktur atas gedung kantor tersebut dapat direncanakan menggunakan sistem balok kastela komposit yang memenuhi persyaratan kekuatan dan kemampuan layan berdasarkan SNI 1729:2020 metode LRFD serta masih memiliki cadangan kapasitas.

English Abstract

This study addresses one research question: how to redesign the superstructure of an office building using a steel structure with castellated beams based on AISC Design Guide 31 and the provisions of SNI 1729:2020, employing the Load and Resistance Factor Design (LRFD) method. The subject of the study is a four-story office building 16 m tall in Malang, an area with high seismic risk, designed to use BJ-41 steel and 120 mm-thick concrete slabs with a compressive strength of f'c 25 MPa. Castellated beams were selected because the expansion of the profile body increases the cross-sectional height and flexural capacity without adding self-weight, thereby preventing an increase in seismic inertia forces while also providing openings for MEP installation pathways. The design procedure was organized sequentially: loading was performed in accordance with SNI 1727:2020, seismic loads were calculated using the equivalent static method in accordance with SNI 1726:2019, internal forces were obtained from ETABS modeling, the I-beam profile geometry referred to AISC Design Guide 31, and all strength and serviceability checks were calculated manually based on SNI 1729:2020 using the LRFD method. Seismic analysis using site class SE yielded SDS = 0.69 G and SD1 = 0.64 G, corresponding to Seismic Design Category D. Consequently, a Special Moment-Resisting Frame System (R = 8) was used, resulting in a base shear force V = 996.71 kN from the seismic load W = 11,604.90 kN. The 12-meter-span main beam is designed as a cast-in-place beam formed by expanding a WF 500×200×10×16 profile with an expansion ratio k = 1.5, resulting in a cross-sectional height dg = 750 mm, a tee height of 125 mm, a web opening height ho = 500 mm, a cut angle of 60° (within the range of 58°–62°), and 22 openings with a web-to-post length of 125.54 mm, without increasing the steel weight per meter of length (remaining at 89.6 kg/m). Composite action is achieved with 23 shear connectors (⌀19 mm studs) in two rows per half-span, accompanied by the closure of ten openings in the highshear zone. Other elements include 6-meter-span main beams WF 400×200×8×13 (86.8% partial composite), secondary beams WF 300×150×6.5×9 (full composite), and H-columns 428×407×20×35 with an interaction ratio of 0.507, while the connections are designed toxxiv use high-strength A325 M20 bolts and E70 electrode fillet welds in accordance with SNI 1729:2020 Chapter J. All strength and serviceability checks resulted in a capacity ratio of less than 1.0, with the highest value of 0.883 for the vertical shear check of the post-composite cast-in-place beam serving as the determining limit condition. Thus, the upper structure of the office building can be designed using a composite cast-in-place beam system that meets the strength and serviceability requirements based on SNI 1729:2020 using the LRFD method and still has a capacity margin.

Item Type: Thesis (Sarjana)
Identification Number: 052607
Uncontrolled Keywords: balok kastela, struktur baja komposit, LRFD, SNI 1729:2020, AISC Design Guide 31, beban gempa, ETABS
Subjects: 600 Technology (Applied sciences) > 624 Civil engineering
Divisions: Fakultas Teknik > Teknik Sipil
Depositing User: Imam Hambali
Date Deposited: 27 Aug 2026 01:46
Last Modified: 27 Aug 2026 01:46
URI: http://repository.ub.ac.id/id/eprint/262199
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
Agae Pratama.pdf
Restricted to Registered users only

Download (10MB)

Actions (login required)

View Item View Item