Rancang Bangun Pengembangan Sistem ChargeDischarge Energi Pada External Defibrillator Bifasik Dan Monofasik Berbasis H-Bridge Insulated Gate Bipolar Transistor.

Nurrohman, Muhammad Yogi and Dr. Ir. Ponco Siwindarto, M.Eng.Sc. and Ir. Zainul Abidin, S.T., M.T., M.Eng., Ph.D (2023) Rancang Bangun Pengembangan Sistem ChargeDischarge Energi Pada External Defibrillator Bifasik Dan Monofasik Berbasis H-Bridge Insulated Gate Bipolar Transistor. Magister thesis, Universitas Brawijaya.

Abstract

Henti jantung mendadak atau Sudden Cardiac Death (SCD) merupakan salah satu penyebab utama kematian di seluruh dunia. Salah satu penyebab SCD adalah gangguan pada jantung yang terjadi ketika jantung berdetak terlalu cepat sehingga frekuensinya tidak dapat dihitung atau fibrilasi. Penanganan yang dapat diberikan untuk mengatasi fibrilasi yaitu tindakan defibrilasi pada penderita menggunakan defibrilator eksternal. Berdasarkan penyaluran energinya defibrilator dibagi menjadi dua yaitu bifasik dan monofasik. Oleh karena itu, sebuah defibrilator eksternal bifasik dan monofasik dirancang dengan fitur dapat diatur penyaluran energinya. Pemilihan mode bifasik dan monofasik dirancang menggunakan rangkaian H-Bridge Insulated Gate Bipolar Transistor (IGBT) yang dikendalikan mikrokontroler. Penggunaan IGBT pada topologi H-Bridge karena kebutuhan time discharging kurang dari 25ms sesuai dengan standar medis. Selain itu, sistem pengaturan energi diperlukan untuk meminimalisasi efek berupa fibrilasi yang lebih parah serta kulit terbakar akibat energi yang terlalu besar. Rentang energi yang dapat diterima oleh tubuh manusia adalah 400-450J tergantung usia dan berat badan. Untuk memenuhi kebutuhan energi tersebut dibutuhkan sistem pengkonversi tegangan tinggi. Tegangan DC 12V dikonversi menjadi 2000V dengan metode switching transformer. Sistem pengaturan energi dilakukan dengan cara mengubah set point tegangan pada kapasitor. Berdasarkan standar medis, time charging yang diperbolehkan adalah tidak lebih dari 6 detik. Proses switching yang dirancang menggunakan frekuensi tinggi sehingga diperlukan inti ferit pada transformer untuk meningkatkan efisiensinya. Output pada transformer juga dilengkapi rectifier full bridge karena proses charge kapasitor membutuhkan arus searah (DC). Kapasitor tersebut bernilai 250uF / 2200V dan digunakan untuk menyimpan energi sementara sebelum diberikan kepada penderita fibrilasi. Berdasarkan pengujian yang telah dilakukan, defibrilator eksternal yang dibuat mampu menghasilkan energi maksimal 500J. Hal ini menunjukan bahwa defibrilator sudah memenuhi spesifikasi kebutuhan energi untuk tindakan defibrilasi. Metode pemberian energi defibrilator ini dapat diatur menggunakan mode monofasik maupun bifasik. Konversi ii tegangan menggunakan metode switching transformer menghasilkan tegangan maksimal 2000V. Selain itu, alat yang dibuat memiliki time charging kurang dari 6 detik dan time discharing kurang dari 20ms. Hal ini menunjukan bahwa defibrilator yang dibuat sudah memenuhi standar medis dalam tindakan defibrilasi. Untuk pengembangan lebih lanjut alat ini dapat dilengkapi dengan sistem exhaust atau pembuang panas dari dalam box serta sistem charging baterai otomatis. Selain itu, alat ini juga perlu modifikasi agar memiliki desain yang ringkas dan mudah dibawa kemanapun.

English Abstract

Sudden Cardiac Death (SCD) is one of the leading causes of death in the word. One of the causes of SCD is a disorder of the heart that occurs when the heart beats too fast so that its frequency cannot be counted or fibrillation. Treatment that can be given to treat fibrillation is defibrillation in patients using an external defibrillator. Based on the distribution of energy, defibrillators are divided into two, that is biphasic and monophasic. Therefore, a biphasic and monophasic external defibrillator is designed with the feature of adjustable energy delivery. The selection of biphasic and monophasic modes is designed using a microcontroller-controlled H-Bridge Insulated Gate Bipolar Transistor (IGBT) circuit. The use of IGBT in the H-Bridge topology is because the discharging time requirement is less than 25ms according to medical standards. In addition, an energy control system is needed to minimize the effects of more severe fibrillation and skin burns due to too much energy. The energy range that can be received by the human body is 400-450J depending on age and body weight. To meet these energy needs, a high-voltage converter system is needed. The 12V DC voltage is converted to 2000V by the switching transformer method. The energy regulation system is done by changing the voltage set point on the capacitor. Based on medical standards, the allowed charging time is no more than 6 seconds. The switching process is designed to use high frequencies so that a ferrite core is needed in the transformer to increase its efficiency. The output of the transformer is also equipped with a full bridge rectifier because the capacitor charging process requires direct current (DC). The capacitor is rated at 250uF / 2200V and is used to temporarily store energy before being given to a fibrillate patient. Based on the tests that have been carried out, the external defibrillator that is made is capable of producing a maximum energy of 500J. This shows that the defibrillator meets the specifications for the energy requirements for defibrillation. This defibrillator energy delivery method can be set using monophasic or biphasic modes. Voltage conversion using the switching transformer method produces a maximum voltage of 2000V. In addition, the device that is made has a charging time of less than 6 seconds and a discharging time of less iv than 20ms. This shows that the defibrillator that is made meets medical standards in defibrillation actions. For further development, this device can be equipped with an exhaust system or heat dissipation from inside the box and an automatic battery charging system. In addition, this device also needs modification so that it has a compact design and is easy to carry anywhere.

Item Type: Thesis (Magister)
Identification Number: 042307
Uncontrolled Keywords: -
Divisions: S2/S3 > Magister Teknik Elektro, Fakultas Teknik
Depositing User: Zainul Mustofa
Date Deposited: 15 Jan 2024 02:24
Last Modified: 15 Jan 2024 02:24
URI: http://repository.ub.ac.id/id/eprint/209708
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
Muhammad Yogi Nurrohman.pdf
Restricted to Registered users only

Download (8MB)

Actions (login required)

View Item View Item