Prasetyo, Muhammad Ichsan (2020) Rancang Bangun Sistem Monitoring Gas Formaldehida Berbasis Sensor Ms1100 Menggunakan Modul Komunikasi Data Rf433mhz. Sarjana thesis, Universitas Brawijaya.
Abstract
Paparan formaldehida dapat menyebabkan gangguan pada kesehatan manusia. Dampak yang dihasilkan yaitu terjadi iritasi pada mata, tenggorokan dan kulit, terjadi gangguan pada sistem pernafasan, bahkan formaldeihida telah ditetapkan sebagai karsinogen bagi manusia. Mengigat bahaya yang ditimbulkan dari formaldehida maka diperlukan suatu sistem untuk memonitoring konsentrasi formaldehida di udara. Pada penelitian ini dibuat alat monitoring gas formaldehida berbasis sensor MS1100 yang dapat mengukur konsentrasi formaldehida dari 0 mg/m3 sampai dengan 14,37 mg/m3 sehingga sistem dapat melakukan pengukuran pada berbagai sumber formaldehida dengan baik dan benar, serta diketahui bahwa alat ini memiliki resolusi 0,01 mg/m3. Selain itu alat ini dilengkapi dengan modul RF433MHz sebagai perangkat komunikasi data. Dengan adanya hal ini dapat memudahkan pemakai dalam melakukan pengukuran gas formaldehida secara kontinu. Jarak komunikasi optimal yang dapat dilakukan yaitu sejauh 21 meter dengan delay 0,31 detik dan potensi data yang dapat diterima sebanyak 87,33% dari total pengiriman data. Tetapi alat ini dapat melakukan komunikasi data maksimal sejauh 30 meter dengan delay pengiriman yang lebih lama yaitu selama 0,95 detik dan potensi data yang dapat diterima sebanyak 77,33% dari total pengiriman data.
English Abstract
Exposure to formaldehyde can cause interference with human health. The resulting impact is irritation to the eyes, damage and skin, damage to the respiratory system. Even formaldehyde has been determined as a humans carcinogen. Based on the danger posed by formaldehyde, a system is needed to monitor formaldehyde in the air. In this research, formaldehyde gas monitoring system based on MS1100 sensor that can measure formaldehyde concentrations from 0 mg/m3 to 14,37 mg/m3, so the system can take measurements at various formaldehyde sources properly and correctly, with a resolution of 0.01 mg/m3. In addition this tool is equipped with RF433MHz module as a data communication device. With this, it can facilitate the user in carrying out formaldehyde gas data continuously. Optimal communication distance that can be done is as far as 21 meters with a delay of 0.31 seconds and the potential data that can be received as much as 87.33% of the total data transmission. But this tool can do data communication up to a maximum of 30 meters with a longer delivery delay of 0.95 seconds and the potential data that can be received as much as 77.33% of the total data transmission.
Other obstract
-
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | 0520090276 |
Uncontrolled Keywords: | Sistem monitoring, formaldehida, MS1100, RF433MHz |
Subjects: | 500 Natural sciences and mathematics > 534 Sound and related vibrations > 534.2 Transmission of sound |
Divisions: | Fakultas Matematika dan Ilmu Pengetahuan Alam > Instrumentasi Fisika |
Depositing User: | ismanto |
Date Deposited: | 19 Feb 2021 15:54 |
Last Modified: | 03 Oct 2024 01:57 |
URI: | http://repository.ub.ac.id/id/eprint/183451 |
Text
MUHAMMAD ICHSAN PRASETYO.pdf Download (3MB) |
Actions (login required)
View Item |