Uji Performansi Unit Filtrasi Air Tanah Dengan Sistem Upflow Dan Downflow Untuk Mengurangi Kadar Mangan (Mn) Dan Kekeruhan

Amin, Naufal Fadhil (2019) Uji Performansi Unit Filtrasi Air Tanah Dengan Sistem Upflow Dan Downflow Untuk Mengurangi Kadar Mangan (Mn) Dan Kekeruhan. Sarjana thesis, Universitas Brawijaya.

Abstract

Kebutuhan akan air bersih sangat penting saat ini, terutama di daerah yang jauh dari jangkauan Perusahaan Daerah Air Minum (PDAM). Upaya penjernihan dengan menggunakan metode penyaringan (filtrasi) dengan media filter yang sesuai dapat menjadi solusi dari permasalahan tersebut. Tujuan dari penelitian ini adalah pengujian filtrasi air dengan media fiter yang sederhana dan menurunkan kadar Mangan (Mn) dan kekeruhan air tanah Kabupaten Mojokerto. Penelitian ini dimulai dengan pengujian air tanah terlebih dahulu. Selanjutnya air diolah dengan proses filtrasi dan hasil pengolahan diuji dalam Laboratorium. Pengolahan air dilakukan dengan membandingkan dua rancangan aliran filtrasi dan penggunaan media filter. Rancangan filtrasi dibedakan menjadi dua, yaitu dengan menggunakan aliran upflow dan aliran downflow. Susunan media filter yang digunakan dibedakan menjadi dua yaitu susunan 1 (Zeolite 40 cm, Pasir Silika 20 cm, Ijuk 10 cm, dan Kerikil 15 cm) dan susunan 2 (Zeolite 20 cm, Karbon Aktif 20 cm, Pasir Silika 20 cm, Ijuk 10 cm, dan Kerikil 15 cm). Pengolahan dilakukan selama 210 menit, dengan pengambilan sampel hasil pengolahan dilakukan pada menit ke- 30, 120, dan 210. Hasil pengolahan dibandingkan dengan Peraturan Menteri Kesehatan Republik Indonesia No. 32 Tahun 2017 dengan parameter Mangan (Mn) dan kekeruhan. Selain kadar Mangan (Mn) dan kekeruhan, kecepatan aliran menjadi pertimbangan dalam menentukan rancangan yang paling efektif untuk diterapkan. Berdasarkan hasil penelitian, rancangan unit filtrasi downflow dengan susunan media filter 1 memiliki hasilix penurunan kadar Mangan paling baik dengan lama waktu pengolahan 30 menit dan memiliki kecepatan aliran yang paling tinggi dengan kecepatan aliran akhir sebesar 0,05 m/s. Sedangkan, Rancangan unit filtrasi upflow dengan susunan media filter 2 memiliki hasil penurunan tingkat kekeruhan yang paling baik. Nilai konduktivitas hidrolik terbesar terdapat pada rancangan unit filtrasi upflow dengan susunan media filter 1 yaitu 0,018 m/s. Racangan filtrasi downflow dengan susunan media filter 2 memiliki performa terbaik dalam menurunkan kadar Mangan (Mn). Analisis finansial dari racangan filtrasi downflow dengan media filter 2 menunjukkan kelayakan perancangan dengan hasil analisis NPV sebesar Rp. 470.370,58, dengan efisiensi usaha (R/C Ratio) sama dengan 1, waktu pengembalian modal (PP) selama 2,7 tahun, dan harga jual per m3 air bersih hasil filtrasi sebesar Rp. 1.778,07. Berdasarkan hasil penelitian, masih perlu ditambahkan metode pengolahan lanjutan agar hasil pengolahan lebih baik dan sesuai dengan baku mutu yang telah ditetapkan. Selain itu masih perlu dilakukan perbaikan pada rancangan unit filtrasi agar kemampuan pengolahan yang dihasilkan lebih maksimal.

English Abstract

The need for clean water is very important now, especially in areas far from the reach of Regional Water Supply Companies (PDAMs). Efforts to purify using filtering methods with suitable filter media can be the solution to these problems. The purpose of this study was to test water filtration with simple fiter media and reduce Manganese (Mn) levels and turbidity of groundwater in Mojokerto Regency. This research began with groundwater testing first. Furthermore, water is processed by a filtration process and the processing results are tested in the Laboratory. Water treatment is done by comparing two designs of filtration flow and the use of filter media. Filtration design is divided into two, namely by using upflow flow and downflow flow. The composition of the filter media used is divided into two, arrangement 1 (Zeolite 40 cm, Silica Sand 20 cm, Palm Fiber 10 cm, and Gravel 15 cm) and arrangement 2 (Zeolite 20 cm, Activated Carbon 20 cm, Silica Sand 20 cm, Palm Fiber 10 cm, and 15 cm gravel). Processing was carried out for 210 minutes, with samples taken from processing at 30, 120, and 210 minutes. The results of processing were compared with the Regulation of the Minister of Health of the Republic of Indonesia No. 32 of 2017 with the parameters Manganese (Mn) and turbidity. In addition to Manganese (Mn) and turbidity levels, flow velocity is consider in determining the most effective design to be applied.xi Based on the results of the study, the design of the downflow filtration unit with filter media arrangement 1 has the best reduction in Manganese content with a processing time of 30 minutes and has the highest flow velocity with a final flow rate of 0.05 m/s. Meanwhile, the upflow filtration unit with filter media arrangement 2 has the best reduction in turbidity level. The largest value of hydraulic conductivity is found in the upflow filtration unit design with filter media arrangement 1 which is 0.018 m/s. Downflow filtration with filter media arrangement 2 has the best performance in reducing Manganese (Mn) levels. Financial analysis of downflow filtration with filter media arrangement 2 shows design feasibility with the results of NPV analysis of Rp. 470,370.58, with business efficiency (R/C Ratio) equal to 1, return on capital (PP) for 2.7 years, and selling price per m3 of clean water as much as Rp. 1,778.07. Based on the results of the study, it is still necessary to add further processing methods so that the processing results are better and in accordance with established quality standards. In addition, improvements to the design of the filtration unit still need to be done so that the resulting processing capability is more maximal

Other obstract

-

Item Type: Thesis (Sarjana)
Identification Number: SKR/FTP/2019/165/052002081
Uncontrolled Keywords: Efisiensi, Kualitas Air Bersih, Unit Filtrasi, Clean Water Quality, Efficiency, Filtration Unit
Subjects: 600 Technology (Applied sciences) > 628 Sanitary engineering > 628.1 Water supply > 628.16 Testing analysis, treatment, pollution countermeasures > 628.161 Testing and analysis / Groundwater--Pollution--Measurement
Divisions: Fakultas Teknologi Pertanian > Keteknikan Pertanian
Depositing User: Nur Cholis
Date Deposited: 13 Aug 2020 01:58
Last Modified: 21 Oct 2021 04:01
URI: http://repository.ub.ac.id/id/eprint/181128
[thumbnail of NAUFAL FADHIL AMIN (2).pdf]
Preview
Text
NAUFAL FADHIL AMIN (2).pdf

Download (8MB) | Preview

Actions (login required)

View Item View Item