Estimasi Dosis Efektif Citra Ct Scan Kepala Dengan Variabel Kvp, Mas Dan Dose Length Product Untuk Mendapatkan Dosis Efektif 2 Msv ( Icrp 103 ) DI RSU Dr. SUDONO MADIUN

Felix, Iwant (2019) Estimasi Dosis Efektif Citra Ct Scan Kepala Dengan Variabel Kvp, Mas Dan Dose Length Product Untuk Mendapatkan Dosis Efektif 2 Msv ( Icrp 103 ) DI RSU Dr. SUDONO MADIUN. Sarjana thesis, Universitas Brawijaya.

Abstract

Penggunaan modalitas sinar-X telah membantu untuk mendiagnosis gangguan / penyakit dalam tubuh manusia. Dalam spektrum gelombang elektromagnetik, sinar-X memiliki energi yang cukup besar, yaitu 100ev - 150 keV, panjang gelombang antara 10 nanometer - 100 pikometer dan frekuensi 30 petahertz - 30 exahertz. Sinar-X adalah radiasi pengion. Sistem pemindaian sinar-X yang terkomputerisasi telah menyebabkan perkembangan teknologi medis yang semakin pesat. Pindai gambar lebih detail dengan CT-scan, terutama karena ada Multi-Slice Multi Scan Detector. Memindai objek melalui tabung sinar-X yang berputar pada objek yang sedang dipindai. Harus dipertimbangkan bahwa radiasi dari sinar-X CT-scan lebih besar dari pada sinar-X konvensional. Pemantauan dosis radiasi untuk pasien adalah prinsip dasar optimasi dengan tidak mengurangi informasi gambar diagnostik. Penelitian ini dilakukan untuk menentukan perubahan dalam variabel kVp, mAs, dan scan area yang diperkirakan sebagai dosis efektif optimal (2 mSv) sehingga sesuai dengan rekomendasi ICRP 103. Perhitungan dosis efektif menggunakan faktor empiris k 0,0023 mSv.mGy1.cm- 1 dikalikan dengan DLP. Faktor paparan yang sering dilakukan adalah 120 kV, 450 mAs, CTDI vol 58.1 mGy.

English Abstract

The use of X-ray modalities has helped to diagnose disorders / diseases in the human body. In the electromagnetic wave spectrum, X-rays have considerable energy, namely 100ev - 150 keV, wavelengths between 10 nanometers - 100 picometers and frequencies of 30 petahertz - 30 exahertz. X-rays are ionizing radiation. Computerized X-ray scanning systems have led to increasingly rapid development of medical technology. Scan images in more detail with CT scans, especially because there is a Multi-Slice Multi Scan Detector. Scan an object through an X-ray tube that rotates on the object being scanned. It must be considered that radiation from CT scan X-rays is greater than conventional X-rays. Monitoring radiation doses for patients is a basic principle of optimization by not reducing diagnostic image information. This study was conducted to determine changes in the kVp, mAs, and scan area variables which were estimated as optimal effective doses (2 mSv) so that they were in accordance with ICRP 103 recommendations. Effective dose calculations using empirical factors k (0.0023 mSv.mGy-1.cm- 1) multiplied by DLP. The exposure factors that are often carried out are 120 kV, 450 mAs, CTDI vol 58.1 mGy.

Other obstract

-

Item Type: Thesis (Sarjana)
Identification Number: SKR/MIPA/2019/343/052001498
Uncontrolled Keywords: X-ray, ionisasi, CT scan, kVp, mAs, Dose Length Product, CTDI vol, dosis efektif
Subjects: 500 Natural sciences and mathematics > 518 Numerical analysis > 518.5 Numerical approximation