Perbandinga Pengaruh Variasi Cooling Bath Terhadap Pembetukan Hidrat Gas Campuran Pronana Butana Tekanan 2 Bar Pada Instalasi Alat Stirrer Tank & Vessel tank

Santoso, Nur Iman (2019) Perbandinga Pengaruh Variasi Cooling Bath Terhadap Pembetukan Hidrat Gas Campuran Pronana Butana Tekanan 2 Bar Pada Instalasi Alat Stirrer Tank & Vessel tank. Sarjana thesis, Universitas Brawijaya.

Abstract

Hidrat gas alam terbentuk dari percampuran gas alam dengan air pada tekanan dan suhu yang tepat untuk membentuk kristal es. Tedapat rongga-rongga didalam hidrat yang di dalamnya terisi oleh partikel gas alam sebagai pengisinya. Gas yang terdapat di dalam hidrat antara lain yaitu propana, butana, etana, dan ,metana. Gas yang terdapat didalam hidrat ini yang dapat dipergunakan. Sudah banyak penilitian yang di lakukan untuk melihat karakteristik dari hidrat . salah satunya yaitu pengaruh alat yang digunakan dalam pembentukan terhadap karakteristik gas hidrat campuran propana dan butana. Karakteristik ini meliputi laju pembentukan, stabilitas hidrat dan kapasitas penyimpanan hidrat. Pentingnya validasi adalah untuk membuktikkan bahwa data tersebut benar. Pengaruh instalasi alat akan mempengaruhi pembentukan hidrat. Alat yang digunakan adalah stirred tank dalam pembentukannya menggunakan variasi temperatur 271 K, 273 K dan 275 K. Perbandingan laju pembentukan hidrat dinyatakan dalam bentuk banyaknya konsumsi gas hidrat propana butana. Konsumsi gas (mol) paling banyak terjadi pada suhu cooling bath 275 K pada alat stirred tank sebesar 0,00602 mol berbanding 0,00590 mol pada alat vessel tank. Perbandingan stabilitas gas hidrat propana butana dinyatakan dalam banyaknya mol gas yang terurai. Tingkat stabilitas hidrat terkecil pada suhu cooling bath yang sama 271 K terjadi pada Instalasi alat stirred tank dengan jumlah gas yang terurai sebesar 0,00012 mol dan 0,00024 pada alat vessel tank. Kapasitas penyimpanan hidrat teoritis tertinggi pada suhu cooling bath yang sama 275 K ada pada instalasi alat stirred tank dengan nilai sebesar 0,8041394 V/V dan 0,735329949 V/V pada alat vessel tank. Validasi nilai konsumsi gas (mol) aktual dan teoritis menunjukkan kecenderungan yang sama namun pada nilai teoritis memiliki nilai lebih tinggi daripada nilai aktual dengan selisih nilai yang sangat kecil sekali.

English Abstract

Natural gas hydrate is formed by mixing natural gas with water at the right pressure and temperature to form ice crystals. There are cavities in the hydrate which are filled with natural gas particles as their fillers. The gas contained in hydrates include propane, butane, ethane, and methane. The gas contained in this hydrate can be used. A lot of research has been done to see the characteristics of hydrates. One of them is the effect of the tools used in the formation of the characteristics of the gas hydrate mixture of propane and butane. These characteristics include the rate of formation, hydrate stability, and hydrate storage capacity. The importance of validation is to verify that the data is correct. The effect from an installation tool will affect the formation of hydrate. The used tool is a stirred tank to form hydrate using variation of temperature 271 K, 273 K, and 275 K. The ratio of hydrate formation rate is stated in the amount of propane and butane hydrate gas consumption. The consumption of gas (mol) is mostly happened at the cooling bath temperature of 275 K in stirred tank equal to 0,00602 mol compared to 0,00590 mol on vessel tank. The stability comparison of propane and butane hydrate gas is stated in the number of moles of decomposed gases. The smallest level of hydrate stability at the same cooling bath temperature of 271 K occurs in the installation of stirred tank with the amount of gas decomposed by 0,00012 mol and 0,00024 mol in vessel tank. The highest theoretical hydrate storage capacity at the same cooling bath temperature of 274 K is in the installation of stirred tank with a value of 0,8041394 V/V and 0,735329949 V/V on vessel tank. The actual and theoretical validity value of gas (mol) consumption shows the same tendency but at the theoretical value has a higher value than the actual value with a very small value difference.

Other obstract

-

Item Type: Thesis (Sarjana)
Identification Number: SKR/FT/2019/31/051904511
Uncontrolled Keywords: Gas hidrat, Gas Propana Butana, Laju Pembentukan, Stabilitas, Kapasitas Penyimpanan, Stirred tank, Hydrate gas, Butane Propane Gas, Rate of Establishment, Stability, Storage capacity, Stirred tank
Subjects: 600 Technology (Applied sciences) > 620 Engineering and allied operations > 620.1 Engineering mechanics and materials
Divisions: Fakultas Teknik > Teknik Mesin
Depositing User: Budi Wahyono Wahyono
Date Deposited: 21 Oct 2020 06:00
Last Modified: 21 Oct 2020 06:00
URI: http://repository.ub.ac.id/id/eprint/173547
Full text not available from this repository.