Pengaruh Rasio Tinggi-Lebar (Hw/Lw) Terhadap Kapasitas Beban Lateral Maksimum, Daktilitas, Dan Pola Retak Dinding Geser Bertulangan Ringan Akibat Beban Lateral Siklik

Utomo, Mochammad Surya Budi (2017) Pengaruh Rasio Tinggi-Lebar (Hw/Lw) Terhadap Kapasitas Beban Lateral Maksimum, Daktilitas, Dan Pola Retak Dinding Geser Bertulangan Ringan Akibat Beban Lateral Siklik. Magister thesis, Universitas Brawijaya.

Abstract

Letak geografis Indonesia menyebabkan sebagian besar wilayahnya dalam potensi gempa yang tinggi, oleh sebab itu sistem strukturnya wajib didesain tahan gempa. Elemen struktur vertikal pada suatu sistem struktur yang berfungsi menahan beban gempa adalah dinding geser. Dinding geser berfungsi menahan beban gempa, karena memiliki momen lentur dan kekakuan yang tinggi dalam hal menahan beban gempa dibandingkan elemen struktur vertikal yang lain. Konfigurasi pada suatu sistem struktur pada umumnya sangat bervariasi, sehingga mengakibatkan elemen-elemen pembentuk struktur terbentuk bervariasi. Dengan adanya hal tersebut, khususnya untuk elemen struktur dinding geser bisa terbentuk langsing (slenders walls) dan persegi (squat walls). Dinding geser bertulangan adalah dinding geser yang memiliki rasio tulangan longitudinal dan rasio tulangan transversal minimal dari yang disyaratkan code. Dinding geser bertulangan pada umumnya dapat dijumpai daerah yang memiliki intensitas gempa rendah sampai sedang. Pengujian ini dilakukan untuk mengidentifikasi pengaruh rasio tinggi-lebar dari struktur dinding geser bertulangan ringan terhadap kapasitas beban lateral, daktilitas simpangan, kekakuan simpangan, serta pola retak akibat beban siklik. Pengujian siklik dilakukan pada benda uji dinding geser yang memiliki ukuran 800x400 mm, 800x600mm, dan 800x800mm. Material penyusun benda uji memakai mutu beton normal (f’c) yaitu 20 MPa dan diameter untuk tulangan longitudinal dan tulangan transversal memakai yaitu Ø6, dengan tegangan leleh (fy) yaitu 240 MPa. Rasio tulangan longitudinal (ρv) dan transversal (ρh) yang digunakan pada masing-masing benda uji adalah 0,283% dan 0,349%. Selain diberikan beban siklik, juga diberikan beban aksial sebesar 3% dari kapasitas aksial nominal (Pn) masing-masing benda uji. Hasil selama pengujian menunjukkan bahwa, material penyusun benda uji, baik itu untuk beton maupun tulangan sudah memenuhi syarat minimum rencana, yaitu 21.45 MPa untuk beton, dan 282,94 MPa untuk tulangan. Kapasitas beban lateral serta kekakuan simpangan tertinggi dimiliki benda uji SW 1,0, baru setelah itu benda uji SW 1,3, dan SW 2,0. Daktilitas simpangan tertinggi dimiliki benda uji SW 2,0, baru setelah itu benda uji SW 1,3, dan SW 1,0. Pola retak yang dihasilkan pada masing-masing benda uji memiliki karaktersitik yang mirip, yaitu sama-sama retak yang ditimbulkan hanya terjadi pada bagian dasar dinding, serta terjadinya bukaan (gap opening) pada bagian dasar dinding.

English Abstract

The geographical location of Indonesia causes most of its area in high seismic potential, therefore the structure system must be designed to be earthquake resistant. The vertical structural element in a structural system that functions to withstand earthquake loads is a shear wall. The shear wall serves to withstand earthquake loads, because it has bending moments and high stiffness in terms of earthquake resistance compared to other vertical structural elements. Configuration in a structural system in general varies widely, resulting in the formation of structural elements are varied. Given this, especially for shear wall structure elements can form slenders walls and squat walls. Repeating shear walls are shear walls that have longitudinal reinforcement ratios and minimal transverseal reinforcing ratios of the required code. Repeating shear walls in general can be found areas that have a low to moderate earthquake intensity. This test was performed to identify the effect of the height-width ratio of the lightly sliding wall structure to the lateral load capacity, the ductility of the drift, the stiffness of the deviation, as well as the crack pattern due to the cyclic load. The cyclic test was performed on a shear wall test object having a size of 800x400 mm, 800x600mm, and 800x800mm. The material of the test object uses the normal concrete quality (f'c) which is 20 MPa and the diameter for longitudinal reinforcement and the transverse reinforcing use is Ø6, with a yield stress (fy) of 240 MPa. The longitudinal (ρv) and transversal (ρh) reinforcement ratios used in each specimen were 0.283% and 0.349%. In addition to cyclic loading, axial load is also given 3% of the nominal axial capacity (Pn) of each specimen. The results during the test show that the material of the composite material, both for concrete and reinforcement, meets the minimum requirements of the plan, is 21.45 MPa for concrete, and 282.94 MPa for reinforcement. The lateral load capacity and the highest deviation stiffness are tested by SW 1.0, only after the SW 1.3, and SW 2.0 test specimens. The highest deviation density belongs to the SW 2.0 test object, only then the test object SW 1.3, and SW 1.0. The crack patterns generated on each specimen have similar characteristics, that is, the cracks that occur only occur at the bottom of the wall, as well as the gap opening at the bottom of the wall.

Item Type: Thesis (Magister)
Identification Number: TES/693.54/UTO/p/2017/041707184
Uncontrolled Keywords: BUILDING, REINFORECED CONCRETE CARTHQUAKE EFFECTS, RATIO ANALYSIS, REINFORCED CONCRETE, LATERAL LOADS, CONCRETE - DUCTILITY, CONCRETE - CRACKING, SHEAR WALLS
Subjects: 600 Technology (Applied sciences) > 696 Utilities
Divisions: S2/S3 > Magister Teknik Sipil, Fakultas Teknik
Depositing User: Nur Cholis
Date Deposited: 24 Aug 2017 07:07
Last Modified: 26 Oct 2020 07:30
URI: http://repository.ub.ac.id/id/eprint/1641