Tingginya kebutuhan energi mengharuskan langkah penghematan energi termasuk pada bangunan gedung komersil. Gedung PT Petrokimia Gresik memiliki orientasi dengan sisi bujur terpanjang menghadap ke arah barat dan timur, dimana pembagian double loaded mengakibatkan ruang-ruang kerja berada tepat pada sisi tersebut. Pengolahan selubung bangunan menggunakan bukaan transparan dengan proporsi mencapai 80%. Tidak nampak adanya penggunaan media bayang sehingga sinar matahari langsung diterima dan mengakibatkan tingginya temperatur. Hal ini mengakibatkan diperlukannya unit-unit pendingin tambahan yang akhirnya berdampak pada besarnya penggunaan energi. Metode dalam penelitian ini menggunakan metode deskriptif evaluatif digunakan untuk menguraikan secara ril kondisi eksisting serta mengukur dan mengkaji pola penggunaan energi. Penjabaran kondisi eksisting objek studi dilakukan secara observasi maupun wawancara, sedang pengukuran energi digunakan metode audit energi yang mengacu pada prosedur audit energi SNI 6196:2011. Selanjutnya digunakan metode eksperimental dalam mengkaji rekomendasi. Pendekatan arsitektural dilakukan langkah rekayasa desain selubung bangunan serta simulasi dengan menggunakan software untuk mengetahui seberapa besar kontribusi yang memungkinkan, sedang dalam pendekatan teknis dilakukan langkah rekalkulasi penggunaan energi. Hasil audit energi rinci didapatkan IKE yang mencapai 261 kWh/m2/tahun dimana angka tersebut berada di atas standar nasional maupun internasional. Aspek yang mendominasi penggunaan energi secara keseluruhan adalah sistem pendinginan dengan besar konsumsi total mencapai 2.070.785 kWh/tahun atau setara 188,19 kWh/year/m2. Berdaskan beberapa masukan, analisis, dan simulasi, didapatkan 3 alternatif terbaik untuk olah selubung yakni penggantian material transparan dengan sistem double galzing bercoating Spectrally Selective, Media bayang overhang kombinasi celah vertikal, dan selubung ganda bermaterial masif dan transparan. Selanjutnya alternatif terbaik tersebut dikombinasikan menjadi alternatif baru dimana hasil terbaik adalah kombinasi double glazing spectrally dengan selubung ganda. Alternatif ini mampu memberikan efisiensi penurunan mencapai 3,18% dengan rata-rata mencapai 2,26%. Adapun dikombinasikan dengan penggantian peralatan berbasis hemat energi, hasil penghematan total mencapai 41,1%. Dari keseluruhan langkah yang telah dilakukan, dihasilkan penghematan konsumsi energi dari 2.872.061 kWh/tahun menjadi 1.690.982,14 kWh/tahun. Angka IKE akhir setelah dilakukan rekomendasi adalah sebesar 153,67 kWh/m2/tahun, angka tersebut 41,1% lebih hemat dari sebelumnya 261 kWh/m2/tahun.

English Abstract

The high energy demand constrains to regulate energy conservation including commercial buildings. The PT Petrokimia Gresik building is located in such orientation which the longest sides of the building are facing to west and east direction which always receiving the annual rays of the sun. The double-loaded division locates the work spaces along the side of the building. Building envelope uses transparent material with a proportion reaching 80%. There is no provision of shading devices used to prevent direct sunlight. This causes the increasing of heat inside. Therefore, addition of refrigeration units are needed and causes the large amounts of energy use. The methods used in this reasearch are evaluative descriptive method and experimental method. Evaluative descriptive used to describe the existing conditions, to measure and also review the patterns of energy use. The explaination of the existing condition of the object carried out by observation and interview, while measuring the energy refers to the SNI 6196: 2011 energy audit procedure as an energy audit method. Experimental method used to analyze and simulate recommendations. The architectural approach is carried out in the steps of making alternative designs and also using software to find out what is possible, while the technical approach is carried out in the steps of recalculating the energy use. The result of detailed audit said that IKE's reached 261 kWh/m2/year, the numbers were above national and international standards. The dominating aspect of energy use is cooling system with a large total of 2,070,785 kWh/year or equivalent to IKE 188.19 kWh/m2/year. Based on points of inputs, analyzes, and simulations, found the 3 best alternatives which are to adjust transparent material with a double glazing and Spectrally Selective coating system, shading devices that containt overhangs with combination of vertical slits, and double skin that using combination of massive and transparent material. Next, Those 3 alternatives are combined into new alternatives and the best one is the combination between adjusting transparent material with a double glazing Spectrally Selective coating system and double skin that using combination of massive and transparent material. This alternative is able to provide a decrease in efficiency of 3.18% with an average of 2.26%. With a combination of technical approach, the total yield reaches 41.1%. Of all the steps taken, the energy use can be reduced from 2,872,061 kWh/ year becomes 1,690,982.14 kWh/year. The final IKE after the recommendation is 153.67 kWh/m2/year, the number is 41.1% more efficient than the previous 261 kWh/m2/year.

Item Type: Thesis (Sarjana)
Identification Number: SKR/FT/2018/1174/051900124
Uncontrolled Keywords: Konservasi Energi, Gedung Kantor, Selubung Bangunan Energy Conservation, Office Building, Building Envelope
Subjects: 700 The Arts > 720 Architecture > 720.4 Special topics of architecture > 720.47 Architecture and the environment > 720.472 Energy resources
Divisions: Fakultas Teknik > Arsitektur
Depositing User: Budi Wahyono Wahyono
Date Deposited: 13 Jun 2019 01:57
Last Modified: 28 Oct 2021 07:20
URI: http://repository.ub.ac.id/id/eprint/162684
[thumbnail of Edi Jamal Abdillah.pdf]
Preview
Text
Edi Jamal Abdillah.pdf

Download (50MB) | Preview

Actions (login required)

View Item View Item