Kinerja Sistem Ventilasi Alami Pada Masjid Besar Ainul Yaqin Sunan Giri Gresik

Fitria, Nur Wakhida (2018) Kinerja Sistem Ventilasi Alami Pada Masjid Besar Ainul Yaqin Sunan Giri Gresik. Sarjana thesis, Universitas Brawijaya.

Abstract

Masjid Besar Ainul Yaqin Sunan Giri Gresik merupakan salah satu masjid tertua di kabupaten gresik. Sebagai masjid bersejarah Gresik dan sering dikunjungi para wisatawan, diharap mampu memberikan kenyaman termal terhadap penggunanya. Ventilasi alami adalah salah satu cara pengendali termal. Perkembangan penduduk mengakibatkan kebutuhan kapasitas masjid perlu ditambah. Sehingga adanya perkembangan pembangunan masjid. Pembangunan masjid tersebut berdampak pada kinerja ventilasi dalam masjid. adanya bangunan fasilitas pendukung yang memiliki dua lantai dengan ketinggian bangunan 7 meter, menghalangi angin yang masuk ke dalam masjid. Adapun pada ruang sholat wanita, bukaan tidak mengarah pada arah angin datang. Bukaan pada ruang sholat pria yang mengarah pada ruang lain. Tujuan dari penelitian adalah untuk mengoptimalkan kinerja ventilasi alami pada Masjid Besar Ainul Yaqin Sunan Giri Gresik dengan tanpa merubah bentuk asli bangunan. Metode yang digunakan dalam penelitian ini adalah metode deskriptif eksperimental. Yang dimaksud metode deskriptif adalah mengolah data primer yang ada dilapangan dengan teori dasar dan standar yang yang terkait. Sedangkan metode eksperimental dalam penelitian ini adalah melakukan rekayasa bukaan menggunakan program komputer. Dalam penelitian ini program yang digunakan adalah Autodesk Flow Design. Data primer yang dikumpulkan adalah kondisi iklim ruang berupa suhu, kelembaban, dan kecepatan udara dalam ruang dengan waktu pengukuran dilakukan pada subuh, duhur, ashar, dan maghrib. Berdasarkan tujuan penelitian variabel terikat dalam penelitian ini adalah kemerataan udara, kecepatan udara, dan turbulensi. Sementara variable kontrol dalam penelitian ini adalah jenis bukaan, dimensi bukaan, dan posisi bukan. Hasil analisis kondisi eksisting Masjid Besar Ainul Yaqin Sunan Giri Gresik menunjukaan masjid memiliki kinerja ventilasi yang beragam setiap ruangnya dan tergolong cukup baik. Namun, kenyamanan termal pada ruang masjid belum tercapai menurut standar ASHRAE khususnya pada waktu sholat dhuhur. Kenyamanan termal dapat dioptimalkan dengan mengoptimalkan kinerja sistem ventilasi alami dengan rekayasa bukaan. Rekayasa bukaan yang direkomendasikan tetap mempertimbangkan aspek konservasi dari bangunan. Hasil dari rekayasa bukaan berupa lubang ventilasi dan penerapan sistem stack effect mampu menaikkan kecepatan udara pada zona wanita, memperluas kemerataan aliran udara, dan memperkecil jumlah titik turbulensi. Sehingga kinerja sistem cross vetilation menjadi lebih baik. Sementara pada zona rombongan rekayasa bukaan berupa jendela vertical pivot, transom, dan penerapan sistem stack effect mampu memperkecil kecepatan udara yang memasuki ruang.

English Abstract

Ainul Yaqin Great Mosque Sunan Giri Gresik is one of the oldest mosques in the district of Gresik. As a historical Gresik mosque and frequented by tourists, it is expected to be able to provide thermal comfort to its users. Natural ventilation is one way of controlling thermal. The development of the population resulted in the need to increase the capacity of the mosque So that there is a development of mosque construction. The construction of the mosque had an impact on the performance of ventilation in the mosque. there is a building supporting facilities that have two floors with a height of 7 meters, blocking the wind entering the mosque. As for the female prayer room, openings do not lead to the coming wind direction. Openings in men's prayer rooms that lead to other spaces. The purpose of the study was to optimize the performance of natural ventilation at the Ainul Yaqin Grand Mosque in Sunan Giri Gresik without changing the original shape of the building. The method used in this research is descriptive experimental method. The definition of descriptive method is to process primary data that is in the field with the basic theory and related standards. While the experimental method in this study is to make openings engineering using a computer program. In this study the program used is Autodesk Flow Design. Primary data collected are climatic conditions in the form of temperature, humidity, and air velocity in the space with the time of measurement carried out at dawn, duhur, ashar, and maghrib. Based on the research objectives the dependent variables in this study are air evenness, air velocity, and turbulence. While the control variables in this study are the types of openings, dimensions of openings, and position not. The results of the analysis of the existing conditions of the Ainul Yaqin Grand Mosque Sunan Giri Gresik show that mosques have varied ventilation performance in each space and are quite good. However, thermal comfort in the mosque space has not been achieved according to ASHRAE standards, especially at the dhuhur prayer times. Thermal comfort can be optimized by optimizing the performance of natural ventilation systems with engineered openings. Recommended engineering openings consider the conservation aspects of the building. The results of engineering openings in the form of ventilation holes and the application of the stack effect system are able to increase the air velocity in the female zone, expand the evenness of air flow, and reduce the number of turbulence points. So that the performance of the cross vetilation system gets better. While in the openings engineering zone the vertical pivot, transom, and stack effect systems are able to reduce the speed of air entering the space.

Item Type: Thesis (Sarjana)
Identification Number: SKR/FT/2018/1020/051811285
Uncontrolled Keywords: kinerja ventilasi, sistem ventilasi, bukaan, rekayasa bukaan. ventilation perfomanced, ventilation system, openings, engineered openings.
Subjects: 600 Technology (Applied sciences) > 697 Heating, ventilating, air-conditioning engineering > 697.9 Ventilation and air conditioning; heating, ventilation, air-conditioning in specific kinds of buildings > 697.956 2 Heating, ventilation, air-conditioning of mosques
Divisions: Fakultas Teknik > Arsitektur
Depositing User: Budi Wahyono Wahyono
Date Deposited: 06 Mar 2019 07:36
Last Modified: 08 Mar 2022 08:37
URI: http://repository.ub.ac.id/id/eprint/162255
[thumbnail of Nur Wakhida Fitria.pdf]
Preview
Text
Nur Wakhida Fitria.pdf

Download (32MB) | Preview

Actions (login required)

View Item View Item