Performance Evaluation of Double Wall in Reducing Building Energy Consumption

Widaya, Ristu (2014) Performance Evaluation of Double Wall in Reducing Building Energy Consumption. Magister thesis, Universitas Brawijaya.

Abstract

Dalam beberapa tahun terakhir, pemanasan global dan kecerobohan energi memiliki perhatian yang signifikan untuk dihindari. Bangunan adalah salah satu konsumen energi terbesar dan kontributor terbesar untuk meningkatkan CO 2. Dinding ganda adalah salah satu metode elemen bangunan yang menjadi populer untuk dimanfaatkan dalam beberapa tahun terakhir. Beberapa penelitian menyebutkan metode ini dapat mengurangi dampak suhu fluktuatif. Meskipun beberapa penelitian telah dilakukan untuk membuktikan bahwa metode ini dapat berkurang suhu udara dan pendinginan permintaan energi, aplikasi tertentu dari dinding ganda dengan keteraturan di antara bahan, celah udara dan parameter O R seperti bangunan orientasi sisi tidak diperhatikan. Oleh karena itu, mungkin menimbulkan pertanyaan, kombinasi dinding ganda mana yang dapat bekerja sebagai optimal untuk mengurangi permintaan energi pendinginan. Berdasarkan masalah latar belakang SE, penelitian ini bertujuan untuk menyelidiki kombinasi material dan celah udara yang optimal dari dinding ganda dalam hal mengurangi konsumsi energi pendinginan dan juga untuk menyelidiki dampak bangunan orientasi sisi ganda. Untuk menentukan hasil SE, penelitian ini disimulasikan dengan menggunakan EnergyPlus dalam perangkat lunak DesignBuilder. Hasil diperoleh bahwa pemanfaatan dinding ganda dengan kombinasi antara blok ganda dan kesenjangan udara 100mm di semua sisi bangunan diberikan dampak signifikan menjadi pengurangan konsumsi energi pendinginan hingga 31,90% dalam setahun. Pemanfaatan dinding ganda tergantung pada bangunan orientasi sisi karena jumlah gain panas matahari yang berbeda. Nilai-U Bahan juga dipengaruhi dalam kinerja dinding ganda. Pengurangan konsumsi energi pendingin berbanding terbalik dengan meningkatkan lebar celah udara. Tetapi, dengan meningkatkan kesenjangan udara dengan lebar 100mm atau lebih besar hanya membantu persentase pengurangan dalam jumlah yang lebih kecil.

English Abstract

In recent years, global warming and recklessness of energy has significant attention to be avoided. Building is one of biggest energy consumer and largest contributors to increase of CO 2 . Double wall is one of building element method which became popular to utilized in recent years. Several studies mentioned this method can be reduced impact of fluctuative temperature. Although some of studies have been done to prove that this method can be reduced air temperature and cooling energy demand, particular application of double wall with regularity among materials, air gaps and o r parameters such as buildings side orientation are no attention to date. Hence, it may raise question, which double-wall combination can work as its optimum to reduce cooling energy demand. Based on se background issue, this study aim is to investigate optimum combination of materials and air gaps of double wall in terms of reducing cooling energy consumption and also to investigate impact of buildings side orientation in double wall utilization. In order to determine se result, this study was simulated by using EnergyPlus in DesignBuilder software. result obtained that double wall utilization with combination between double block and 100mm air gap in all of building sides was given significant impact into cooling energy consumption reduction up to 31,90% in a year. Double wall utilization is depending on buildings side orientation because of different amount of solar heat gain. U-value of materials are also affected into double wall performance. cooling energy consumption reduction is inversely proportional by increasing air gap width. But, by increasing air gap of 100mm width or above is only help percentage of reduction in smaller amount.

Item Type: Thesis (Magister)
Identification Number: TES/690.12/WID/p/041407165
Subjects: 600 Technology (Applied sciences) > 690 Construction of buildings > 690.1 Structural elements
Depositing User: Endro Setyobudi
Date Deposited: 03 Dec 2014 13:08
Last Modified: 03 Dec 2014 13:08
URI: http://repository.ub.ac.id/id/eprint/160248
Full text not available from this repository.

Actions (login required)

View Item View Item