Pembuatan dan Karakterisasi Elektroda Selektif Ion (ESI) Bikromat Tipe Kawat Terlapis Berbasis Kitosan

Zulkarnain (2012) Pembuatan dan Karakterisasi Elektroda Selektif Ion (ESI) Bikromat Tipe Kawat Terlapis Berbasis Kitosan. Magister thesis, Universitas Brawijaya.

Abstract

Keberadaan senyawa Cr(VI) dalam perairan dapat disebabkan oleh pencemaran limbah yang berasal dari aktivitas industri seperti industri elektroplating. Cr(VI) bersifat toksik, jika terakumulasi dalam tubuh dapat menyebabkan kerusakan genetis dan kanker. Senyawa Cr(VI) dapat ditentukan dengan metoda spektrofotometer sinar tampak pada λ 540 nm menggunakan pereaksi difenilkarbazida, akan tetapi metoda ini tidak dapat menentukan kadar Cr(VI) dalam bentuk spesi bikromat nya . Untuk mengatasi permasalahan ini digunakan metoda lain yang dapat mengukur kadar bikromat, yaitu metoda ESI. Metoda ESI memiliki beberapa kelebihan yaitu sederhana, dapat mengukur kadar bikromat, kepekaan alat yang cukup tinggi, membutuhkan sampel dalam jumlah yang sedikit, dan tidak menggunakan pereaksi. Tujuan penelitian ini adalah membuat dan mengkarakterisasi ESI bikromat tipe kawat terlapis sehingga dapat digunakan sebagai metoda alternatif untuk penentuan bikromat dalam sampel limbah elektroplating disamping metoda standar spektrofotometer sinar tampak. Untuk mencapai tujuan tersebut maka dibuat ESI bikromat yang membrannya dioptimasi berdasarkan harga ∆d m , kemudian ESI bikromat diuji pengaruh lingkungan yang meliputi waktu prakondisi, ion asing, pH, dan temperatur. Data hasil pengukuran metoda ESI divalidasi dengan cara membandingkannya dengan metoda spektrofotometer sinar tampak melalui uji korelasi regresi pada batas kepercayaan 95 %. Hasil penelitian menunjukkan bahwa ESI bikromat tipe kawat terlapis memiliki karakteristik yang Nernstian dengan faktor Nernst 29.40 mV/dekade, rentang konsentrasi linier 10 -1 -10 -4 M, batas deteksi 8,00 ppm, waktu respon 30 detik, selektif terhadap bikromat, dan usia pemakaian 60 hari. Waktu prakondisi optimum adalah 30 menit, urutan selektifitas ion bikromat ion sulfat ion asetat pH 1-4 dan temperatur 20-40 0 C tidak mempengaruhi kinerja ESI bikromat tipe kawat terlapis. Metoda ESI dan metoda standar tidak berbeda nyata sehingga metoda ESI bikromat tipe kawat terlapis dapat digunakan sebagai metoda alternatif untuk penentuan kadar bikromat dalam sampel elektroplating disamping metoda standar.

English Abstract

presence of Cr(VI) compounds in waters can be caused by waste pollution from industrial activities such as industrial electroplating. If Cr(VI) compounds accumulated in body, it is able to cause genetic damage and cancer. Levels of Cr(VI) can be determined by method of visible spectrophotometer at λ of 540 nm using diphenilcarbazide reagent, but this method can not determine levels of Cr(VI) in form of dichromate. To overcome this problem, we need to use ano r method that can measure levels of dichromate, that is ISE method. ISE method has several advantages y are simple, able to measure level of Cr(VI) in form of dichromate, high sensitivity, requiring sample in very small amount, and free of reagent requirement. purpose of this study w as preparation and characterization of ISE dichromate type of coated wire as alternative method to determine of dichromate on electroplating waste water. To reach that goal, n ISE with optimize d membrane were made based on ∆d m prices. ISE dichromate was examined to influence test of enviromental factor s covering preconditions time, stange ion, pH, and temperature. Under o ptimum condition, dichromate ISE was validated by measuring syn tic and real sample, and results were compared to obtained from standard visible spectrophotometry using regression corelation tes at 95 % confidence limit. result show ed characteristics of dichromate ISE with Nernst factor of 29.40 mV/dec, linier concentration range of 10 -1 -10 -4 M, respon time of 30 seconds, detection limit of 8,00 ppm, selective to dichromate, and life time of 60 days. optimum precondition time is 30 minutes, selectivity: dichromate sufate acetate, and under pH 1-4 and temperature 20-40 0 C was not affect ed performance of ISE dichromate. results of measurement ISE methods and standard methods visible light spectrophotometer is not significantly different, so it can be as alternative method to determine of dichromate on electroplating waste water.

Item Type: Thesis (Magister)
Identification Number: TES/660.297 24/ZUL/p/041200758
Subjects: 600 Technology (Applied sciences) > 660 Chemical engineering and related technologies > 660.2 General topics in chemical engineering
Divisions: S2/S3 > Magister Matematika, Fakultas MIPA
Depositing User: Endro Setyobudi
Date Deposited: 25 Apr 2012 12:46
Last Modified: 25 Apr 2012 12:46
URI: http://repository.ub.ac.id/id/eprint/160094
Full text not available from this repository.

Actions (login required)

View Item View Item