Ali, Muchammad (2013) Desain Unit Kontrol Pompa Air pada Sistem Pompa Listrik Tenaga Angin. Magister thesis, Universitas Brawijaya.
Abstract
Implementasi wind-electric pump system (WEPS) BWC 1500-PD stand alone di wilayah provinsi Nusa Tenggara Timur sudah berjalan dengan baik. Implementasi WEPS tersebut sebagai pengisi bak air untuk mengairi kebun bibit tanaman buah dan sayuran, dan distribusi air bersih. Lokasi WEPS tersebar tidak merata karena ketersebaran potensi sumber tenaga anginnya. Namun implementasi WEPS tersebut tidak dapat bertahan lama karena konfigurasinya mempunyai komponen pump control unit (PCU) yang lemah . Tujuan penelitian ini adalah menjalankan kembali fungsi WEPS BWC 1500-PD dengan mendesain dan membuat PCU pengganti. Fungsi PCU adalah mengatur frekuensi suplai daya listrik pompa listrik sentrifugal (PLS) dalam rentang yang diinginkan. Disamping itu PCU juga berfungsi untuk merespons sinyal input dari sensor pengaman operasional WEPS. Kontrol V/f diterapkan pada WEPS untuk membuat PLS bekerja pada torsi konstan dan pada kecepatan yang diinginkan. Dari hasil pengujian, diketahui bahwa PCU pengganti berhasil membuat PLS bekerja dalam rentang frekuensi naik antara 40 Hz dan 90 Hz dan rentang frekuensi turun antara 70 Hz dan 30 Hz. PCU pengganti juga terbukti dapat merespons sinyal input dari sensor pengaman dengan cara memutuskan suplai daya listrik dari permanent magnet generator (PMG) . Kontrol V/f diperoleh dengan menggabungkan rangkaian konverter frekuensi pada konfigurasi WEPS dan terbukti bahwa PLS dapat bekerja pada torsi yang konstan dan pada kecepatan yang diinginkan.
English Abstract
Implementation of stand alone wind-electric pump system (WEPS) BWC 1500-PD in province of East Nusa Tenggara has been running well. implementation of WEPS as water tubs filler to irrigate nurseries of fruit and vegetable crops, and clean water distribution. WEPS locations were unevenly distributed due to distributed of potential sources of wind energy. However, implementation of WEPS did not last long because of configuration had a weak pump control unit (PCU) component. purpose of this sis research is to rerun function of WEPS (BWC 1500-PD) by designing and creating replacement of PCU. PCU function is to regulate frequency of power supply from permanent magnet generator (PMG) to centrifugal electric pump (CEP) in desired range. Besides, it also serves to respond input signal from WEPS operational protective sensors. V/f control is applied on WEPS to make PLS works on constant torque and desired speed. From test results , it is known that replacement of PCU made up CEP worked in increased frequency range between 40 Hz and 90 Hz and reduced frequency range between 70 Hz and 30 Hz. replacement of PCU also showed to respond to input signals from WEPS operational protective sensors by unplugging power supply from PMG. V/f control is obtained by combining frequency converter circuit to WEPS configuration and proved that ECP can work on constant torque and desired speed .
Item Type: | Thesis (Magister) |
---|---|
Identification Number: | TES/621.69/ALI/d/041304385 |
Subjects: | 600 Technology (Applied sciences) > 621 Applied physics > 621.6 Blowers, fans, pumps |
Divisions: | S2/S3 > Magister Teknik Elektro, Fakultas Teknik |
Depositing User: | Endro Setyobudi |
Date Deposited: | 03 Jun 2013 13:40 |
Last Modified: | 03 Jun 2013 13:40 |
URI: | http://repository.ub.ac.id/id/eprint/158719 |
Actions (login required)
View Item |