Firmansyah, MAgus (2014) Pengukuran Neutron Cepat Di Ruang Linac Medis Menggunakan Detektor Jejak Nuklir Cr-39. Sarjana thesis, Universitas Brawijaya.
Abstract
Akselerator linear medis (linac) merupakan pesawat pemercepat partikel yang digunakan dalam radioterapi. Linac dapat menghasilkan foton sinar-X energi tinggi yang sangat efektif untuk menyembuhkan tumor atau kanker. Akan tetapi linac yang dioperasikan lebih dari 8 MV dapat menghasilkan radiasi tambahan berupa neutron. Neutron tersebut dapat meningkatkan dosis pada pasien selama proses terapi maupun pada pekerja. Pada penelitian ini dilakukan pengukuran neutron untuk mengetahui distribusi dosis dan fluks neutron, khususnya neutron cepat, di ruang linac medis tersebut. Pengukuran neutron dilakukan dengan menggunakan detektor jejak nuklir CR-39, yang dilapisi radiator polietilen dan filter Cu. Detektor dikalibrasi terlebih dahulu menggunakan sumber neutron standar 241Am-Be di laboratorium neutron PTKMR-BATAN dan diperoleh kurva kalibrasi berupa garis lurus linear. Sejumlah detektor kemudian diletakkan pada beberapa titik di ruangan 10 MV linac medis di rumah sakit Siloam Simatupang. Setelah penyinaran, detektor dietsa dengan larutan NaOH 6,25 N pada suhu 70ºC selama 7 jam, kemudian jejak pada detektor dihitung dengan menggunakan mikroskop optik. Hasil pengukuran menunjukkan distribusi dosis dan fluks neutron cepat di ruang linac medis tersebut nilainya bervariasi mulai dari yang terbesar di titik isocenter pada meja pasien, kemudian menurun seiring semakin jauh jaraknya dari isocenter, dan minimum pada ruang kontrol.
English Abstract
A medical linear accelerator (linac) is a type of particle accelerator that used in radiotherapy. Linac can generate high energy photon X-ray to treat tumor or cancer effectively. But when operating linac at energies above 8 MV, neutrons are produced as secondary radiation. These unwanted neutrons contribute to the patient dose during the treatment, as well as radiation workers in linac room. The aim of this research was to measure and investigate the distribution of neutron dose and fluence, particularly for fast neutron, in the medical linac room. In this research, CR-39 nuclear track detectors, covered by polyethylene radiator and Cu filter, were applied to measure neutron. The detectors were calibrated using a 241 Am-Be neutron source at neutron laboratory of PTKMR-BATAN and obtained a linear line of calibration curve. A number of detectors were placed and distributed inside and outside the therapy room of 10 MV medical linac at Siloam Hospital Simatupang. After exposure, chemical etching was performed using 6,25 N NaOH solution at 70°C, for 7 hours and the tracks were counted using an optical microscope. The neutron dose and fluence distribution were found maximum at isocenter point in the patient couch. By increasing the distance from isocenter, the neutron dose and fluence decreased rapidly and the minimum at control room.
Item Type: | Thesis (Sarjana) |
---|---|
Identification Number: | SKR/MIPA/2014/112/051401391 |
Subjects: | 500 Natural sciences and mathematics > 530 Physics |
Divisions: | Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika |
Depositing User: | Budi Wahyono Wahyono |
Date Deposited: | 25 Feb 2014 09:15 |
Last Modified: | 25 Oct 2021 02:47 |
URI: | http://repository.ub.ac.id/id/eprint/153729 |
Preview |
Text
Laporan_Skripsi_-_M._Agus_Firmansyah.pdf Download (4MB) | Preview |
Actions (login required)
![]() |
View Item |