Pengaruh Variasi jarak Alat Sambung Terhadap Beban Lateral Maksimum Dan Kekakuan Akibat Beban Siklik (Quasi-Statis) Pada Portal Baja Canai Dingin 2D

Anorogo, Bagus (2020) Pengaruh Variasi jarak Alat Sambung Terhadap Beban Lateral Maksimum Dan Kekakuan Akibat Beban Siklik (Quasi-Statis) Pada Portal Baja Canai Dingin 2D. Sarjana thesis, Universitas Brawijaya.

Abstract

Pemanfaatan baja canai dingin mulai digunakan dalam konstruksi sebagai struktur bangunan. Namun material ini memiliki ketebalan yang relatif tipis dan ringan sehingga rentan terjadi kegagalan pada penyatuan elemen-elemennya. Maka perlu adanya perencanaan yang baik pada keseluruhan sistem sambungan terhadap beban-beban yang bekerja seperti beban lateral akibat gempa. Dalam penelitian ini dilakukan pembebanan siklik terhadap portal baja canai dingin yang bertujuan mengetahui pengaruh sambungan terhadap beban lateral dan kekakuan struktur. Dalam penelitian ini dirancang dua jenis portal yang memiliki perbedaan pada jarak alat sambung dari sumbu sekrup ke kolom 2 cm, ke balok 2 cm (SC 2-2) dan dari sumbu sekrup ke kolom 2 cm, ke balok 1 cm (SC 2-1). Digunakan 2 benda uji pada setiap variasi benda uji. Pembebanan menggunakan metode displacement control yaitu memperhatikan drift ratio sebesar 2%, 4%, 6%, dan 8%. Hasil pengamatan dan penelitian yang didapatkan adalah beban lateral puncak dan kekakuan struktur, dimana kapasitas tahanan pada benda uji SC 2-1 lebih besar dibandingkan dengan benda uji SC 2-2. Rata-rata nilai beban lateral puncak dan kekakuan tangensial serta secant yaitu benda uji SC 2-1 4,898 kg, 0,993 kg/cm dan 0,840 kg/cm serta benda uji SC 2- 2 3,808 kg, 0,888 kg/cm dan 0,728 kg/cm. Hal ini terjadi dikarenakan jarak dari alat sambung SC 2-1 lebih kecil, sehingga pada saat pembebanan sambungan dengan jarak 2-1 bekerja lebih dahulu. Sedangkan pelat sambung pada jarak 2-2 perlu meregang hingga panjang tertentu untuk bekerja secara optimal.

English Abstract

The use of cold-formed steel began to be used on construction as a building structure. However, this material has a relatively thin and thickness so that failure is prone to its elements unification. Therefore, there needs to be a good planning of whole system of connection to the loads that work like the lateral load due to the earthquake. In this research, a cyclic loading of the cold-formed portal aims to determine the influence of connection to lateral load and structure rigidly. In this research the two types of portals that have a difference in the distance of the dial too from the screw axis to the 2 cm column, to the 2 cm beam (SC 2-2) and from the screw axis to the 2 cm column, to the 1 beam (SC2-1). Two test objects are used in each variation of the test. Loading using displacement control method is pay attention to drift ratio of 2%, 4%, 6%, and 8%. The results of observation and the research obtained are the lateral burden of the peak and the rigidly of the structure, where the resistance capacity of the SC 2-1 test object is greater than the SC 2-2 test object. Average peak lateral load value and stiffness of tangential and secant are for SC 2-1 test objects are 4,898 kg, 0,993 kg/cm and 0,840 kg/cm and for SC 2-2 test objects are 3,808 kg, 0,888 kg/cm and 0,728 kg/cm. This happens because the distance from the SC 2-1 connect tool is smaller, so at the time of loading, the connection with a distance 2-1 works fist. While the dial plate at a distance of 2-2 need to stretch to a certain length to work optimally.

Other obstract

-

Item Type: Thesis (Sarjana)
Identification Number: 0520070072
Uncontrolled Keywords: Canai Dingin, Portal, Sambungan, Jarak Alat Sambung, Beban Lateral, Beban Siklik, Kekakuan Tangen, Kekakuan Secant, Histerisis, Kurva Envelope cold formed steel, portals, joints, connecting tool distances, lateral loads, cyclic loads, hysteresis, envelope curve
Subjects: 600 Technology (Applied sciences) > 691 Building materials > 691.7 Iron and steel (ferrous metals)
Divisions: Fakultas Teknik > Teknik Sipil
Depositing User: Bambang Septiawan
Date Deposited: 04 Feb 2021 08:35
Last Modified: 12 Jan 2023 03:14
URI: http://repository.ub.ac.id/id/eprint/182322
[thumbnail of DALAM MASA EMBARGO] Text (DALAM MASA EMBARGO)
0520070072-Bagus Anorogo.pdf
Restricted to Registered users only until 31 December 2023.

Download (6MB)

Actions (login required)

View Item View Item