Pengukuran Jarak Presisi Tinggi Dengan Kombinasi Metode Pulsa-Echo Dan Metode Korelasi Silang Menggunakan Tranduser Ultrasonik.

FadlilKhoironi, Muhammad (2015) Pengukuran Jarak Presisi Tinggi Dengan Kombinasi Metode Pulsa-Echo Dan Metode Korelasi Silang Menggunakan Tranduser Ultrasonik. Sarjana thesis, Universitas Brawijaya.

Abstract

Pengukuran jarak dengan menggunakan tranduser ultrasonik termasuk dalam pengukuran non kontak. Metode yang sering digunakan dalam pengukuran jarak menggunakan tranduser ultrasonik adalah metode pulsa-echo dan metode korelasi silang. Metode pulsa-echo adalah metode yang didasarkan pada pengukuran waktu tempuh gelombang ultrasonik dimulai dari awal gelombang dikirim hingga gelombang diterima. Sedangkan metode korelasi silang didasarkan pada korelasi antara dua gelombang yakni gelombang ultrasonik kirim dan gelombang ultrasonik terima. Penelitian ini mengombinasikan metode pulsa-echo dan metode korelasi silang untuk menghitung waktu tempuh gelombang ultrasonik dan memberikan hasil pengukuran jarak yang lebih presisi. Pengambilan data dilakukan setiap pertambahan jarak 0,01 cm melebihi 1 panjang gelombang ultrasonik.Hasil pengambilan data menunjukkan bahwa tingkat akurasi dan presisi pengukuran jarak menjadi lebih baik dengan error rata-rata di bawah 5% serta rentang pergeseran jarak terkecil yang mampu diukur adalah sebesar 0,02 cm.

English Abstract

Distance measurement using ultrasonic transducers are included in non-contact measurement.The method often used in distance measurement using ultrasonic transducers is pulse-echo method and cross-correlation method. The pulse-echo method based on measuring time of flight from ultrasonic wave calculated at wave transmitted until received. The cross-correlation method based on the correlation between of two waves, ultrasonic wave transmit and ultrasonic wave receive. This study combines pulse-echo method and cross-correlation method to calculate time of flight of ultrasonic wave and give results of distance measurement more precision. The data collection is done every increment 0,01 cm of distance exceeds 1 ultrasonic wavelength. The result of data collection show that the level of accuracy and precision of distance measurement for the better with average error below 5% and smallest shift range distance which can be measured is 0,02 cm.

Item Type: Thesis (Sarjana)
Identification Number: SKR/MIPA/2015/47/051501518
Subjects: 500 Natural sciences and mathematics > 510 Mathematics
Divisions: Fakultas Matematika dan Ilmu Pengetahuan Alam > Matematika
Depositing User: Samsul Arifin
Date Deposited: 25 Feb 2015 14:55
Last Modified: 25 Feb 2015 14:55
URI: http://repository.ub.ac.id/id/eprint/154528
Full text not available from this repository.

Actions (login required)